forked from cms-sw/cmssw
-
Notifications
You must be signed in to change notification settings - Fork 0
/
dt4ml_dqm_sourceclient-live_cfg.py
128 lines (98 loc) · 4.13 KB
/
dt4ml_dqm_sourceclient-live_cfg.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
from __future__ import print_function
import FWCore.ParameterSet.Config as cms
import sys
import os
from Configuration.Eras.Era_Run3_cff import Run3
process = cms.Process("DTDQM", Run3)
unitTest = False
if 'unitTest=True' in sys.argv:
unitTest=True
#----------------------------
#### Event Source
#----------------------------
if unitTest:
process.load("DQM.Integration.config.unittestinputsource_cfi")
from DQM.Integration.config.unittestinputsource_cfi import options
else:
# for live online DQM in P5
process.load("DQM.Integration.config.inputsource_cfi")
from DQM.Integration.config.inputsource_cfi import options
# for testing in lxplus
#process.load("DQM.Integration.config.fileinputsource_cfi")
#from DQM.Integration.config.fileinputsource_cfi import options
#----------------------------
#### DQM Environment
#----------------------------
process.load("DQM.Integration.config.environment_cfi")
#----------------------------
#### DQM Live Environment
#----------------------------
process.dqmEnv.subSystemFolder = 'DT'
process.dqmSaver.tag = "DT"
process.dqmSaver.runNumber = options.runNumber
process.dqmSaverPB.tag = "DT"
process.dqmSaverPB.runNumber = options.runNumber
#-----------------------------
### CUSTOMIZE FOR ML
# prepare the output directory
filePath = "/globalscratch/dqm4ml_" + process.dqmRunConfig.type.value()
if unitTest:
filePath = "./dqm4ml_" + process.dqmRunConfig.type.value()
try:
os.makedirs(filePath)
except:
pass
process.dqmSaver.backupLumiCount = 10
process.dqmSaver.keepBackupLumi = True
process.dqmSaver.path = filePath
process.dqmSaverPB.path = filePath + "/pb"
# disable DQM gui
print("old:",process.DQM.collectorHost)
process.DQM.collectorHost = 'dqm-blackhole.cms'
print("new:",process.DQM.collectorHost)
### END OF CUSTOMIZE FOR ML
# DT reco and DQM sequences
process.load("Configuration.StandardSequences.GeometryRecoDB_cff")
process.load("Configuration/StandardSequences/MagneticField_cff")
process.load("DQM.DTMonitorModule.dt_dqm_sourceclient_common_cff")
#---- for P5 (online) DB access
process.load("DQM.Integration.config.FrontierCondition_GT_cfi")
#---- for offline DB: change and possibly customise the GT
#from Configuration.AlCa.GlobalTag import GlobalTag as gtCustomise
#process.GlobalTag = gtCustomise(process.GlobalTag, 'auto:run2_data', '')
# message logger
process.MessageLogger = cms.Service("MessageLogger",
destinations = cms.untracked.vstring('cout'),
cout = cms.untracked.PSet(threshold = cms.untracked.string('WARNING'))
)
process.dqmmodules = cms.Sequence(process.dqmEnv + process.dqmSaver + process.dqmSaverPB)
process.dtDQMPathPhys = cms.Path(process.unpackers + process.dqmmodules + process.physicsEventsFilter * process.dtDQMPhysSequence)
#process.dtDQMPathCalib = cms.Path(process.unpackers + process.dqmmodules + process.calibrationEventsFilter * process.dtDQMCalib)
process.twinMuxStage2Digis.DTTM7_FED_Source = "rawDataCollector"
process.dtunpacker.inputLabel = "rawDataCollector"
process.gtDigis.DaqGtInputTag = "rawDataCollector"
process.scalersRawToDigi.scalersInputTag = "rawDataCollector"
print("Running with run type = ", process.runType.getRunType())
#----------------------------
#### pp run settings
#----------------------------
if (process.runType.getRunType() == process.runType.pp_run):
pass
#----------------------------
#### cosmic run settings
#----------------------------
if (process.runType.getRunType() == process.runType.cosmic_run):
pass
#----------------------------
#### HI run settings
#----------------------------
if (process.runType.getRunType() == process.runType.hi_run):
process.twinMuxStage2Digis.DTTM7_FED_Source = "rawDataRepacker"
process.dtunpacker.inputLabel = "rawDataRepacker"
process.gtDigis.DaqGtInputTag = "rawDataRepacker"
process.scalersRawToDigi.scalersInputTag = "rawDataRepacker"
process.dtDigiMonitor.ResetCycle = 9999
### process customizations included here
from DQM.Integration.config.online_customizations_cfi import *
print("Final Source settings:", process.source)
process = customise(process)