Muon: need to refocus twice 'first good bin' #7836

Closed
Anders-Markvardsen opened this issue May 2, 2013 · 1 comment
Closed

Muon: need to refocus twice 'first good bin' #7836

Anders-Markvardsen opened this issue May 2, 2013 · 1 comment
Milestone

Comments

@Anders-Markvardsen
Copy link
Member

To reproduce

  1. Open MuonAnalysis interface
  2. In setting make sure for 'Plot Creation' selected to be 'Auto-Update + Overwrite'
  3. and the 'Time axis' is selected to 'Start at First Good Data'
  4. Go to Home tab and load any muon data, e.g. browse to AutoTestdata and select MUSR00015189.nxs
  5. for 'First Good Data' change the value from 0.11 to day 1.11 and hit return or otherwise refocus out of the input box

What you see is that the plot is not updated this, that is the first data plotted should be at 1.11 rather than 0.11

If you go to this input box again and refocus or hit the plot button you get the correct result

@Anders-Markvardsen
Copy link
Member Author

This issue was originally trac ticket 6990