Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Increase OTA fragment size for ZWLR #6758

Closed
AlCalzone opened this issue Apr 10, 2024 · 1 comment
Closed

Increase OTA fragment size for ZWLR #6758

AlCalzone opened this issue Apr 10, 2024 · 1 comment

Comments

@AlCalzone
Copy link
Member

These updates could be MUCH quicker:

2024-04-10T12:24:17.438Z DRIVER « [Node 256] [REQ] [BridgeApplicationCommand]
                                  │ RSSI: -75 dBm
                                  └─[Security2CCMessageEncapsulation]
                                    │ sequence number: 173
                                    │ security class:  S2_Authenticated
                                    └─[FirmwareUpdateMetaDataCCMetaDataReport]
                                        manufacturer id:     634
                                        firmware id:         3
                                        checksum:            0
                                        firmware upgradable: true
                                        max fragment size:   128
                                        hardware version:    1
2024-04-10T12:24:17.439Z CNTRLR   [Node 256] Updating firmware (part 1 / 1)...
2024-04-10T12:24:17.439Z CNTRLR » [Node 256] Starting firmware update...
2024-04-10T12:24:17.455Z SERIAL » 0x012600a900010100189f035600f8f135affa69e002760978db21ecd51cf8f8b23 (40 bytes)
                                  42500000000506b
2024-04-10T12:24:17.456Z DRIVER » [Node 256] [REQ] [SendDataBridge]
                                  │ source node id:   1
                                  │ transmit options: 0x25
                                  │ callback id:      80
                                  └─[Security2CCMessageEncapsulation]
                                    │ sequence number: 86
                                    │ security class:  S2_Authenticated
                                    └─[FirmwareUpdateMetaDataCCRequestGet]
                                        manufacturer id: 0x027a
                                        firmware id:     0x03
                                        checksum:        0x6796
                                        firmware target: 0
                                        fragment size:   28
                                        activation:      false
@AlCalzone
Copy link
Member Author

Already fixed

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment