ble-pasv-mqtt-gw.js not correctly reporting negative temperatures for xiaomi devices #88

Open
jos73 opened this issue Feb 10, 2024 · 2 comments

Comments

@jos73
Copy link

jos73 commented Feb 10, 2024

Negative temperatures are not reported correctly. -8.8c (might not be exact as the temperature fluctuates a bit) is reported as 6544.8c

To Reproduce
Simply place the xiaomi sensor in an environment with negative temperatures (in celcius) and check the mqqt output

Expected behavior
Expected to see negative temperatures reported in MQTT. Both mqqt reports (the one with only temperature and the one with temperature & humidity) are incorrect.

As long as it's still cold enough here I can easily test any fixes.

@jos73
Copy link
Author

jos73 commented Feb 10, 2024

Fixed it (I think), changed

  else if(fmt[pos] === 'H') {
    res[keyArr[pos]] = le ? this.getUInt16LE() : this.getUInt16BE();
  }

to

  else if(fmt[pos] === 'H') {
    res[keyArr[pos]] = le ? this.getInt16LE() : this.getInt16BE();
  }

@sdrsdr
Copy link
Member

sdrsdr commented Feb 12, 2024

getUInt16LE implies Unsigned integer so no negative values are possible. Changing to getInt16BE will allow for negative values so if the data looks ok it should be a valid solution