machinery_power.dm
160 lines (141 loc) · 5.71 KB
/
machinery_power.dm
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
/*
This is /obj/machinery level code to properly manage power usage from the area.
*/
// Note that we update the area even if the area is unpowered.
#define REPORT_POWER_CONSUMPTION_CHANGE(old_power, new_power)\
if(old_power != new_power){\
var/area/A = get_area(src);\
if(A) A.power_use_change(old_power, new_power, power_channel)}
/**
* Returns `TRUE` if the area has power on given channel (or doesn't require power), defaults to `power_channel`.
* May also optionally specify an area, otherwise defaults to `loc.loc`.
*/
/obj/machinery/proc/powered(chan = POWER_CHAN, area/check_area = null)
if(!loc)
return FALSE
//Don't do this. It allows machines that set use_power to 0 when off (many machines) to
//be turned on again and used after a power failure because they never gain the MACHINE_STAT_NOPOWER flag.
//if(!use_power)
// return 1
if(!check_area)
check_area = get_area(src) // make sure it's in an area
if(!check_area || !isarea(check_area))
return FALSE // if not, then not powered
if(chan == POWER_CHAN)
chan = power_channel
return check_area.powered(chan) // return power status of the area
// called whenever the power settings of the containing area change
// by default, check equipment channel & set flag can override if needed
// This is NOT for when the machine's own status changes; update_use_power for that.
/obj/machinery/proc/power_change()
if(stat_immune & MACHINE_STAT_NOPOWER)
return FALSE
var/oldstat = stat
set_stat(MACHINE_STAT_NOPOWER, TRUE)
for(var/thing in power_components)
var/obj/item/stock_parts/power/power = thing
if((!is_powered()) && power.can_provide_power(src))
set_stat(MACHINE_STAT_NOPOWER, FALSE)
else
power.not_needed(src)
. = (stat != oldstat)
if(.)
queue_icon_update()
/// Returns the current power usage draw, based on the state of `use_power`.
/obj/machinery/proc/get_power_usage()
switch(use_power)
if(POWER_USE_IDLE)
return idle_power_usage
if(POWER_USE_ACTIVE)
return active_power_usage
else
return 0
/**
* This will have this machine have its area eat this much power next tick, and not afterwards. Do not use for continued power draw.
* `chan` can be one of the possible values for `power_channel`, or `POWER_CHAN` to use the machine's current configured power channel.
*/
/obj/machinery/proc/use_power_oneoff(amount, chan = POWER_CHAN)
if(chan == POWER_CHAN)
chan = power_channel
. = amount
for(var/thing in power_components)
var/obj/item/stock_parts/power/power = thing
var/used = power.use_power_oneoff(src, ., chan)
. -= used
if(. <= 0)
return
// Same as `use_power_oneoff()`, but dry run; doesn't actually do it. Useful for pre-operation checks.
/obj/machinery/proc/can_use_power_oneoff(amount, chan = POWER_CHAN)
if(chan == POWER_CHAN)
chan = power_channel
. = amount
for(var/thing in power_components)
var/obj/item/stock_parts/power/power = thing
var/used = power.can_use_power_oneoff(src, ., chan)
. -= used
if(. <= 0)
return
// Do not do power stuff in New/Initialize until after ..()
/obj/machinery/Initialize()
REPORT_POWER_CONSUMPTION_CHANGE(0, get_power_usage())
GLOB.moved_event.register(src, src, .proc/update_power_on_move)
power_init_complete = TRUE
. = ..()
// Or in Destroy at all, but especially after the ..().
/obj/machinery/Destroy()
GLOB.moved_event.unregister(src, src, .proc/update_power_on_move)
REPORT_POWER_CONSUMPTION_CHANGE(get_power_usage(), 0)
. = ..()
/// Handles updating machinery power whenever the machine is moved. Calls `area_changed()` by default.
/obj/machinery/proc/update_power_on_move(atom/movable/mover, atom/old_loc, atom/new_loc)
area_changed(get_area(old_loc), get_area(new_loc))
/// Handles machinery power updates if the area the machine is in changes. Called by `update_power_on_move()`.
/obj/machinery/proc/area_changed(area/old_area, area/new_area)
if(old_area == new_area)
return
var/power = get_power_usage()
if(!power)
return // This is the most likely case anyway.
if(old_area)
old_area.power_use_change(power, 0, power_channel)
if(new_area)
new_area.power_use_change(0, power, power_channel)
power_change() // Force check in case the old area was powered and the new one isn't or vice versa.
// The three procs below are the only allowed ways of modifying the corresponding variables.
/// Updates the `use_power` variable to the new value and updates the machine's area's power grid.
/obj/machinery/proc/update_use_power(new_use_power)
if(!power_init_complete)
use_power = new_use_power
return // We'll be retallying anyway.
if(use_power == new_use_power)
return
var/old_power = get_power_usage()
use_power = new_use_power
var/new_power = get_power_usage()
REPORT_POWER_CONSUMPTION_CHANGE(old_power, new_power)
/// Updates the machine's `power_channel` to the new value and updates the machine's area's power grid.
/obj/machinery/proc/update_power_channel(new_channel)
if(power_channel == new_channel)
return
if(!power_init_complete)
power_channel = new_channel
return
var/power = get_power_usage()
REPORT_POWER_CONSUMPTION_CHANGE(power, 0)
power_channel = new_channel
REPORT_POWER_CONSUMPTION_CHANGE(0, power)
/// Updates the machine's `*_power_usage` to the new value and updates the machine's current power consumption state if applicable.
/obj/machinery/proc/change_power_consumption(new_power_consumption, use_power_mode = POWER_USE_IDLE)
var/old_power
switch(use_power_mode)
if(POWER_USE_IDLE)
old_power = idle_power_usage
idle_power_usage = new_power_consumption
if(POWER_USE_ACTIVE)
old_power = active_power_usage
active_power_usage = new_power_consumption
else
return
if(power_init_complete && (use_power_mode == use_power))
REPORT_POWER_CONSUMPTION_CHANGE(old_power, new_power_consumption)
#undef REPORT_POWER_CONSUMPTION_CHANGE