/
SHRIMP_PRAWN.xsd
384 lines (374 loc) · 23 KB
/
SHRIMP_PRAWN.xsd
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
<?xml version="1.0" encoding="utf-8"?>
<xs:schema xmlns:xs="http://www.w3.org/2001/XMLSchema"
xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
attributeFormDefault="unqualified"
elementFormDefault="qualified"
targetNamespace="https://raw.githubusercontent.com"
xmlns="https://raw.githubusercontent.com">
<xs:annotation>
<xs:documentation xml:lang="en">
This schema defines the contents of a SHRIMP PRAWN data file.
Copyright 2015 CIRDLES.org.
Licensed under the Apache License, Version 2.0 (the "License");
you may not use this file except in compliance with the License.
You may obtain a copy of the License at
http://www.apache.org/licenses/LICENSE-2.0
Unless required by applicable law or agreed to in writing, software
distributed under the License is distributed on an "AS IS" BASIS,
WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
See the License for the specific language governing permissions and
limitations under the License.
Created: 24.October.2015
Revised: 14.November.2016
</xs:documentation>
</xs:annotation>
<xs:element name="prawn_file">
<xs:complexType>
<xs:sequence>
<xs:annotation>
<xs:documentation xml:lang="en">
Session parameters
</xs:documentation>
</xs:annotation>
<!-- Control software version-->
<xs:element name="software_version" type="xs:string" />
<!-- A ‘run’ is an analysis of a sample. This value indicates the number of analyses contained in the file.
Useful for checking.-->
<xs:element name="runs" type="xs:short" />
<!-- The control software provides space to include comments in the data file. Rarely used as comments are
usually recorded elsewhere.-->
<xs:element minOccurs="0" name="session_quality" type="xs:string" />
<!-- The control software provides space to include comments in the data file. Rarely used as comments are
usually recorded elsewhere-->
<xs:element minOccurs="0" name="session_comments" type="xs:string" />
<!-- The name or number of the mount being analysed. Recorded as part of the session information in the
control software-->
<xs:element minOccurs="0" name="mount" type="xs:string" />
<!-- From SHRIMP SW v3.51 SHR 2-->
<xs:element minOccurs="0" name="login_comment" type="xs:string" />
<!-- From SHRIMP SW v3.51 SHR 2-->
<xs:element minOccurs="0" name="stdZrU" type="xs:string" />
<!-- From SHRIMP SW v3.51 SHR 2-->
<xs:element minOccurs="0" name="stdUOU" type="xs:string" />
<!-- From SHRIMP SW v3.51 SHR 2-->
<xs:element minOccurs="0" name="stdPbU" type="xs:string" />
<!-- From SHRIMP SW v3.51 SHR 2-->
<xs:element minOccurs="0" name="stdAge" type="xs:string" />
<!-- From SHRIMP SW v3.51 SHR 2-->
<xs:element minOccurs="0" name="stdConcU" type="xs:string" />
<!-- An analysis-->
<xs:element maxOccurs="unbounded" name="run">
<xs:complexType>
<xs:sequence>
<xs:annotation>
<xs:documentation xml:lang="en">
Run parameters - see type RunParameterNames for enumeration.
</xs:documentation>
</xs:annotation>
<xs:element maxOccurs="unbounded" name="par">
<xs:complexType>
<xs:attribute name="name" type="RunParameterNames" use="required" />
<xs:attribute name="value" type="xs:string" use="required" />
</xs:complexType>
</xs:element>
<xs:element name="run_table">
<xs:complexType>
<xs:sequence>
<xs:element maxOccurs="unbounded" name="entry">
<xs:complexType>
<xs:sequence>
<xs:annotation>
<xs:documentation xml:lang="en">
Run Table Entry parameters - see type RunTableEntryParameterNames for enumeration.
</xs:documentation>
</xs:annotation>
<xs:element maxOccurs="unbounded" name="par">
<xs:complexType>
<xs:attribute name="name" type="RunTableEntryParameterNames" use="required" />
<xs:attribute name="value" type="xs:string" use="required" />
</xs:complexType>
</xs:element>
</xs:sequence>
</xs:complexType>
</xs:element>
</xs:sequence>
<xs:attribute name="entries" type="xs:unsignedByte" use="required" />
<xs:attribute name="parameters" type="xs:unsignedByte" use="required" />
<xs:attribute name="sample_name" type="xs:string" use="required" />
</xs:complexType>
</xs:element>
<xs:element name="set">
<xs:complexType>
<xs:sequence>
<xs:annotation>
<xs:documentation xml:lang="en">
Set parameters - see type SetParameterNames for enumeration.
</xs:documentation>
</xs:annotation>
<xs:element maxOccurs="unbounded" name="par">
<xs:complexType>
<xs:attribute name="name" type="SetParameterNames" use="required" />
<xs:attribute name="value" type="xs:string" use="required" />
</xs:complexType>
</xs:element>
<xs:element maxOccurs="unbounded" name="scan">
<xs:complexType>
<xs:sequence>
<xs:element maxOccurs="unbounded" name="measurement">
<xs:complexType>
<xs:sequence>
<xs:annotation>
<xs:documentation xml:lang="en">
Measurement parameters - see type MeasurementParameterNames for enumeration.
</xs:documentation>
</xs:annotation>
<xs:element maxOccurs="unbounded" name="par">
<xs:complexType>
<xs:attribute name="name" type="MeasurementParameterNames" use="required" />
<xs:attribute name="value" type="xs:string" use="required" />
</xs:complexType>
</xs:element>
<xs:element maxOccurs="unbounded" name="data">
<xs:complexType>
<xs:simpleContent>
<xs:extension base="xs:string">
<xs:attribute name="name" type="xs:string" use="required" />
</xs:extension>
</xs:simpleContent>
</xs:complexType>
</xs:element>
</xs:sequence>
</xs:complexType>
</xs:element>
</xs:sequence>
<xs:attribute name="number" type="xs:unsignedByte" use="required" />
</xs:complexType>
</xs:element>
</xs:sequence>
</xs:complexType>
</xs:element>
</xs:sequence>
</xs:complexType>
</xs:element>
<!-- A post run-->
<xs:element minOccurs="0" name="poxi">
</xs:element>
</xs:sequence>
</xs:complexType>
</xs:element>
<xs:simpleType name="RunParameterNames">
<xs:restriction base="xs:string">
<!-- The identification of the analysis. Typically it is ‘sample ID · grain number · spot number on grain’-->
<xs:enumeration value="title"/>
<!-- As a historical holdover, it is possible to conduct multiple ‘sets’ of analyses on the same analytical spot.
This is rarely done for typical U-Pb work, and this value will be ‘1’ in nearly all instances.-->
<xs:enumeration value="sets"/>
<!-- The number of mass species being analysed in this run as described in the run table.
It is possible to change the number of mass species during a session, but it is not common practice
as it makes the file difficult to process in one go. Therefore this is a useful value to check to
make sure that all the ‘runs’ in the file are compatible.-->
<xs:enumeration value="measurements"/>
<!-- The number of ‘scans’ is the number of times the mass species run table has been repeated for this analysis.
Typically 5 to 7, although can range more widely for non U-Pb or experimental work.-->
<xs:enumeration value="scans"/>
<!-- The value set in the control software used to correct counting for dead time in the detector.-->
<xs:enumeration value="dead_time_ns"/>
<!-- The zero value of the secondary beam monitor set by blanking the beam and measuring the resulting
‘dark’ current in the secondary beam monitor. Subtracted from all SBM counts.-->
<xs:enumeration value="sbm_zero_cps"/>
<!-- Whether autocentering was on during analysis. Does not directly factor into calculations,
but may be important for interpretation and quality control.-->
<xs:enumeration value="autocentering"/>
<!-- How the QTY1 lens setting (the first secondary beam tuning) was set in the control software.
This setting can compensate for irregularities on the mount surface or drift of the sample stage
location motors over a long automated session. Does not directly factor into calculations,
but may be important for interpretation and quality control.-->
<xs:enumeration value="qt1y_mode"/>
<!-- Whether the beam was deflected between mass species (usually to protect the detector from large amplitudes).
Unusual to use in typical U-Pb work. Does not directly factor into calculations,
but may be important for interpretation and quality control.-->
<xs:enumeration value="deflect_beam_between_peaks"/>
<!-- The method used to autocentre the mass species. Does not directly factor into calculations,
but may be important for interpretation and quality control.-->
<xs:enumeration value="autocenter_method"/>
<!-- The location of the analytical spot in the x-axis. (On SHRIMP the x-axis is along the line of the secondary
beam, i.e. the distance of the sample surface from the extraction plate, or, broadly, the ‘focus’).
Does not directly factor into calculations, but may be important for interpretation and
quality control.-->
<xs:enumeration value="stage_x"/>
<!-- The location of the analytical spot in the y-axis. (On SHRIMP the y-axis is the ‘east-west’ direction).
Does not directly factor into calculations, but may be important for interpretation and
quality control.-->
<xs:enumeration value="stage_y"/>
<!-- Description-->
<xs:enumeration value="stage_z"/>
<!-- Description-->
<xs:enumeration value="stage_map_quad_cal"/>
<!-- Description-->
<xs:enumeration value="stage_map_cal"/>
<!-- Description-->
<xs:enumeration value="detector_gains"/>
<!-- Description-->
<xs:enumeration value="detector_zero_cps"/>
<!-- Description-->
<xs:enumeration value="EISIE_measured"/>
<!-- Description-->
<xs:enumeration value="EISIE_sets"/>
<!-- Description-->
<xs:enumeration value="detector1_zero_sub_cps"/>
<!-- Description-->
<xs:enumeration value="detector2_zero_sub_cps"/>
<!-- Description-->
<xs:enumeration value="detector3_zero_sub_cps"/>
<!-- Description-->
<xs:enumeration value="detector4_zero_sub_cps"/>
<!-- Description-->
<xs:enumeration value="detector5_zero_sub_cps"/>
<!-- Description-->
<xs:enumeration value="eisie_1_cps"/>
<!-- Description-->
<xs:enumeration value="eisie_2_cps"/>
<!-- Description-->
<xs:enumeration value="eisie_3_cps"/>
<!-- Description-->
<xs:enumeration value="eisie_1_date_time"/>
<!-- Description-->
<xs:enumeration value="eisie_2_date_time"/>
<!-- Description-->
<xs:enumeration value="eisie_3_date_time"/>
<!-- Description-->
<xs:enumeration value="primary_names"/>
<!-- Description-->
<xs:enumeration value="primary_bits"/>
<!-- Description-->
<xs:enumeration value="primary_volts"/>
<!-- Description-->
<xs:enumeration value="secondary_names"/>
<!-- Description-->
<xs:enumeration value="secondary_names_bits"/>
<!-- The digital bit settings matching the lens and steering components listed above. Does not directly
factor into calculations, but may be important for interpretation and quality control.-->
<xs:enumeration value="secondary_bits"/>
<!-- Names of Secondary beam components (lens and steering). Note that not all secondary beam components
have equivalent voltage readings. Does not directly factor into calculations, but may be
important for interpretation and quality control.-->
<xs:enumeration value="secondary_names_volts"/>
<!-- The equivalent voltage settings matching the lens and steering components listed above.
Does not directly factor into calculations, but may be important for interpretation and
quality control.-->
<xs:enumeration value="secondary_volts"/>
<!-- Description-->
<xs:enumeration value="faraday_configuration"/>
<!-- Description-->
<xs:enumeration value="left_mount_name"/>
<!-- Description-->
<xs:enumeration value="left_mount_owner"/>
<!-- Description-->
<xs:enumeration value="right_mount_name"/>
<!-- Description-->
<xs:enumeration value="right_mount_owner"/>
</xs:restriction>
</xs:simpleType>
<xs:simpleType name="RunTableEntryParameterNames">
<xs:restriction base="xs:string">
<!-- Mass species used as reference peak for 204Pb measurement and for calculating composition-->
<xs:enumeration value="label"/>
<!-- Atomic mass unit setting of the mass species. Not used directly in calculations, but may be useful
for quality control to check offsets.-->
<xs:enumeration value="amu"/>
<!-- Description-->
<xs:enumeration value="trim_amu"/>
<!-- Description-->
<xs:enumeration value="autocenter_offset_amu"/>
<!-- The amount of time in seconds that the collector measures the imcoming secondary beam at this mass species.
Used to calculate counting rate for mass species.-->
<xs:enumeration value="count_time_sec"/>
<!-- Time that data acquistion is delayed when magnet is set for this mass species to allow for settling.
Not used in calculations, but may be useful for quality control.-->
<xs:enumeration value="delay_sec"/>
<!-- The position of the collector. Not used in calculations, but may be useful for quality control.-->
<xs:enumeration value="collector_focus"/>
<!-- Amount of time taken to auto-centre mass species. Zero indicates that no autocentring was done at this
mass species. Not used in calculations, but may be usefulf ro quality control.-->
<xs:enumeration value="centering_time_sec"/>
<!-- Description-->
<xs:enumeration value="centering_frequency"/>
<!-- Description-->
<xs:enumeration value="detector_selection"/>
<!-- Description-->
<xs:enumeration value="mc_lm_pos"/>
<!-- Description-->
<xs:enumeration value="mc_hm_pos"/>
<!-- The purpose for measuring the mass species - to be ratioed against the reference, as a reference,
or as a background to be subtracted from all mass species measurements-->
<xs:enumeration value="sc_reference"/>
<!-- The type of detector used to make the measurement of the mass species.
Can be counter (multiplier) or cup (Faraday).-->
<xs:enumeration value="sc_detector"/>
</xs:restriction>
</xs:simpleType>
<xs:simpleType name="SetParameterNames">
<xs:restriction base="xs:string">
<!-- Description-->
<xs:enumeration value="date"/>
<!-- Description-->
<xs:enumeration value="time"/>
<!-- Description-->
<xs:enumeration value="qt1y"/>
<!-- Description-->
<xs:enumeration value="qt1y_volts"/>
<!-- Description-->
<xs:enumeration value="qt1z"/>
<!-- Description-->
<xs:enumeration value="egy"/>
<!-- Description-->
<xs:enumeration value="egz"/>
<!-- Description-->
<xs:enumeration value="egkY"/>
<!-- Description-->
<xs:enumeration value="egkZ"/>
<!-- Description-->
<xs:enumeration value="egcY"/>
<!-- Description-->
<xs:enumeration value="egcZ"/>
<!-- Description-->
<xs:enumeration value="prealphay"/>
<!-- Description-->
<xs:enumeration value="pbm"/>
<!-- Description-->
<xs:enumeration value="eisie_cps"/>
<!-- Description-->
<xs:enumeration value="eisie_date_time"/>
<!-- Description-->
<xs:enumeration value="lab_temperature_degc"/>
</xs:restriction>
</xs:simpleType>
<xs:simpleType name="MeasurementParameterNames">
<xs:restriction base="xs:string">
<!-- Description-->
<xs:enumeration value="detectors"/>
<!-- Description-->
<xs:enumeration value="trim_mass"/>
<!-- Description-->
<xs:enumeration value="time_stamp_sec"/>
<!-- Description-->
<xs:enumeration value="autocentering_result"/>
<!-- Description-->
<xs:enumeration value="autocentering_detector"/>
<!-- Description-->
<xs:enumeration value="196Zr2O"/>
<xs:enumeration value="CaTi2O4"/>
<xs:enumeration value="204Pb"/>
<xs:enumeration value="Bkgnd"/>
<xs:enumeration value="206Pb"/>
<xs:enumeration value="207Pb"/>
<xs:enumeration value="208Pb"/>
<xs:enumeration value="238U"/>
<xs:enumeration value="248ThO"/>
<xs:enumeration value="254UO"/>
<xs:enumeration value="270UO2"/>
<!-- Description-->
<xs:enumeration value="SBM"/>
</xs:restriction>
</xs:simpleType>
</xs:schema>