Notifications
You must be signed in to change notification settings - Fork 13
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
Serial support #86
Comments
Hey, I'm currently interested in this feature and I've tried to hack together some edits in a copy of your integration in order to use the modbus RTU over USB serial. However I can't seem to get it to work, lacking experience with asynchronous Python and knowledge about writing custom Home Assistant integrations. Would it be possible for you to help me out with adding this functionality? I changed the TCP client for the RTU one in the following functon (api.py) def modbus_connect(self, config=None):
# client = modbus_client.SunSpecModbusClientDeviceTCP(
# slave_id=use_config.slave_id,
# ipaddr=use_config.host,
# ipport=use_config.port,
# timeout=TIMEOUT,
# )
client = modbus_client.SunSpecModbusClientDeviceRTU(slave_id=use_config.slave_id, name=use_config.host) Reusing the Unfortunately hacking this is not as simple as I thought and I keep getting the following error: I have verified that my hardware is working and I can get Sunspec data from my SolarEdge inverter on my laptop (although using a different module called "solaredge_modbus"): import solaredge_modbus
inverter = solaredge_modbus.Inverter(device="COM6", baud=115200)
inverter.connect()
if inverter.connected():
print(inverter.read_all())
else:
print("not connected")
inverter.disconnect() Returning the following data: {
"c_id": "SunS",
"c_did": 1,
"c_length": 65,
"c_manufacturer": "SolarEdge",
"c_model": "SE6K-RW0TEBEN4",
"c_version": "0004.0014.0228",
"c_serialnumber": "********",
"c_deviceaddress": 1,
"c_sunspec_did": 103,
"c_sunspec_length": 50,
"current": 1751,
"l1_current": 584,
"l2_current": 584,
"l3_current": 582,
"current_scale": -2,
"l1_voltage": 4155,
"l2_voltage": 4109,
"l3_voltage": 4100,
"l1n_voltage": 2367,
"l2n_voltage": 2388,
"l3n_voltage": 2385,
"voltage_scale": -1,
"power_ac": 4163,
"power_ac_scale": 0,
"frequency": 5001,
"frequency_scale": -2,
"power_apparent": 4168,
"power_apparent_scale": 0,
"power_reactive": -20123,
"power_reactive_scale": -2,
"power_factor": -9988,
"power_factor_scale": -2,
"energy_total": 7459710,
"energy_total_scale": 0,
"current_dc": 5629,
"current_dc_scale": -3,
"voltage_dc": 7509,
"voltage_dc_scale": -1,
"power_dc": 4227,
"power_dc_scale": 0,
"temperature": 3465,
"temperature_scale": -2,
"status": 4,
"vendor_status": 0,
"rrcr_state": 0,
"active_power_limit": 100,
"cosphi": 0,
"commit_power_control_settings": 0,
"restore_power_control_default_settings": 0,
"reactive_power_config": 0,
"reactive_power_response_time": 200,
"advanced_power_control_enable": 1,
"export_control_mode": 0,
"export_control_limit_mode": 0,
"export_control_site_limit": 0
} |
User request for support for serial connection in addition to TCP
Add a configuration option for connection type, TCP or serial with an additional step for connection details.
The text was updated successfully, but these errors were encountered: