Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Two-temperature-plasma incompatible with third-body notation #1220

Closed
ischoegl opened this issue Mar 15, 2022 · 0 comments · Fixed by #1333
Closed

Two-temperature-plasma incompatible with third-body notation #1220

ischoegl opened this issue Mar 15, 2022 · 0 comments · Fixed by #1333
Labels
Input Input parsing and conversion (for example, ck2yaml) Kinetics

Comments

@ischoegl
Copy link
Member

ischoegl commented Mar 15, 2022

Problem description

Per #967/#1015/#1027 the following reaction in test/data/ET_test.yaml

- equation: E + O2 + O2 => O2^- + O2  # Kossyi (1992) Eq.45
  type: two-temperature-plasma
  rate-constant: {A: 1.523e+27, b: -1.0, Ea_T: -100, Ea_Te: 700}

is a three-body reaction, but is currently not handled as such.

Steps to reproduce

Found in #1219

Behavior

Reaction was found using a generic search for implicitly defined third-body colliders

System information

  • Cantera version: [for example, 2.5.0 or the git commit hash] 2.6.0a4
  • OS: [for example, Windows 10]
  • Python/MATLAB/other software versions:
@ischoegl ischoegl added Input Input parsing and conversion (for example, ck2yaml) Kinetics labels Mar 17, 2022
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Labels
Input Input parsing and conversion (for example, ck2yaml) Kinetics
Projects
No open projects
Development

Successfully merging a pull request may close this issue.

1 participant