Notifications
You must be signed in to change notification settings - Fork 13
/
classic_modbusdecoder.py
executable file
·312 lines (282 loc) · 15.7 KB
/
classic_modbusdecoder.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
#!/usr/bin/env python
# --------------------------------------------------------------------------- #
# Handle the modbus data from the Classic.
# The only methon called out of this is getModbusData
# This opens the client to the Classic, gets the data and closes it. It does not
# keep the link open to the Classic.
# --------------------------------------------------------------------------- #
from pymodbus.constants import Endian
from pymodbus.payload import BinaryPayloadDecoder
try:
from pymodbus.client import ModbusTcpClient as ModbusClient # pymodbus 3
MODBUS_VERSION = 3
except ImportError:
from pymodbus.client.sync import ModbusTcpClient as ModbusClient # pymodbus 2
MODBUS_VERSION = 2
from collections import OrderedDict
import logging
import sys
log = logging.getLogger('classic_mqtt')
# --------------------------------------------------------------------------- #
# Read from the address and return the registers
# --------------------------------------------------------------------------- #
def getRegisters(theClient, addr, count):
try:
if MODBUS_VERSION == 2:
result = theClient.read_holding_registers(addr, count, unit=10)
else:
result = theClient.read_holding_registers(addr, count, slave=10)
if result.function_code >= 0x80:
log.error("error getting {} for {} bytes".format(addr, count))
return {}
except:
log.error("Error getting {} for {} bytes".format(addr, count))
return {}
return result.registers
# --------------------------------------------------------------------------- #
# Return a decoder for the passed in registers
# --------------------------------------------------------------------------- #
def getDataDecoder(registers):
if MODBUS_VERSION == 2:
return BinaryPayloadDecoder.fromRegisters(
registers,
byteorder=Endian.Big,
wordorder=Endian.Little)
else:
return BinaryPayloadDecoder.fromRegisters(
registers,
byteorder=Endian.BIG,
wordorder=Endian.LITTLE)
# --------------------------------------------------------------------------- #
# Based on the address, return the decoded OrderedDict
# --------------------------------------------------------------------------- #
def doDecode(addr, decoder):
if (addr == 4100 ):
decoded = OrderedDict([
('PCB', decoder.decode_8bit_uint()), #4101 MSB
('Type', decoder.decode_8bit_uint()), #4101 LSB
('Year', decoder.decode_16bit_uint()), #4102
('Month', decoder.decode_8bit_uint()), #4103 MSB
('Day', decoder.decode_8bit_uint()), #4103 LSB
('InfoFlagBits3', decoder.decode_16bit_uint()), #4104
('ignore', decoder.skip_bytes(2)), #4105 Reserved
('mac_1', decoder.decode_8bit_uint()), #4106 MSB
('mac_0', decoder.decode_8bit_uint()), #4106 LSB
('mac_3', decoder.decode_8bit_uint()), #4107 MSB
('mac_2', decoder.decode_8bit_uint()), #4107 LSB
('mac_5', decoder.decode_8bit_uint()), #4108 MSB
('mac_4', decoder.decode_8bit_uint()), #4108 LSB
('ignore2', decoder.skip_bytes(4)), #4109, 4110
('unitID', decoder.decode_32bit_uint()), #4111
('StatusRoll', decoder.decode_16bit_uint()), #4113
('RsetTmms', decoder.decode_16bit_uint()), #4114
('BatVoltage', decoder.decode_16bit_int()/10.0), #4115
('PVVoltage', decoder.decode_16bit_uint()/10.0), #4116
('BatCurrent', decoder.decode_16bit_uint()/10.0), #4117
('EnergyToday', decoder.decode_16bit_uint()/10.0), #4118
('Power', decoder.decode_16bit_uint()/1.0), #4119
('ChargeStage', decoder.decode_8bit_uint()), #4120 MSB
('State', decoder.decode_8bit_uint()), #4120 LSB
('PVCurrent', decoder.decode_16bit_uint()/10.0), #4121
('lastVOC', decoder.decode_16bit_uint()/10.0), #4122
('HighestVinputLog', decoder.decode_16bit_uint()), #4123
('MatchPointShadow', decoder.decode_16bit_uint()), #4124
('AmpHours', decoder.decode_16bit_uint()), #4125
('TotalEnergy', decoder.decode_32bit_uint()/10.0), #4126, 4127
('LifetimeAmpHours', decoder.decode_32bit_uint()), #4128, 4129
('InfoFlagsBits', decoder.decode_32bit_uint()), #4130, 31
('BatTemperature', decoder.decode_16bit_int()/10.0), #4132
('FETTemperature', decoder.decode_16bit_int()/10.0), #4133
('PCBTemperature', decoder.decode_16bit_int()/10.0), #4134
('NiteMinutesNoPwr', decoder.decode_16bit_uint()), #4135
('MinuteLogIntervalSec', decoder.decode_16bit_uint()), #4136
('modbus_port_register', decoder.decode_16bit_uint()), #4137
('FloatTimeTodaySeconds', decoder.decode_16bit_uint()), #4138
('AbsorbTime', decoder.decode_16bit_uint()), #4139
('reserved1', decoder.decode_16bit_uint()), #4140
('PWM_ReadOnly', decoder.decode_16bit_uint()), #4141
('Reason_For_Reset', decoder.decode_16bit_uint()), #4142
('EqualizeTime', decoder.decode_16bit_uint()), #4143
])
elif (addr == 4360):
decoded = OrderedDict([
('WbangJrCmdS', decoder.decode_16bit_uint()), #4361
('WizBangJrRawCurrent', decoder.decode_16bit_int()), #4362
('skip', decoder.skip_bytes(4)), #4363,4364
('WbJrAmpHourPOSitive', decoder.decode_32bit_uint()), #4365,4366
('WbJrAmpHourNEGative', decoder.decode_32bit_int()), #4367,4368
('WbJrAmpHourNET', decoder.decode_32bit_int()), #4369,4370
('WhizbangBatCurrent', decoder.decode_16bit_int()/10.0), #4371
('WizBangCRC', decoder.decode_8bit_int()), #4372 MSB
('ShuntTemperature', decoder.decode_8bit_int() - 50.0), #4372 LSB
('SOC', decoder.decode_16bit_uint()), #4373
('skip2', decoder.skip_bytes(6)), #4374,75, 76
('RemainingAmpHours', decoder.decode_16bit_uint()), #4377
('skip3', decoder.skip_bytes(6)), #4378,79,80
('TotalAmpHours', decoder.decode_16bit_uint()), #4381
])
elif (addr == 4163):
decoded = OrderedDict([
('MPPTMode', decoder.decode_16bit_uint()), #4164
('Aux1and2Function', decoder.decode_16bit_int()), #4165
])
elif (addr == 4209):
decoded = OrderedDict([
('Name0', decoder.decode_8bit_uint()), #4210-MSB
('Name1', decoder.decode_8bit_uint()), #4210-LSB
('Name2', decoder.decode_8bit_uint()), #4211-MSB
('Name3', decoder.decode_8bit_uint()), #4211-LSB
('Name4', decoder.decode_8bit_uint()), #4212-MSB
('Name5', decoder.decode_8bit_uint()), #4212-LSB
('Name6', decoder.decode_8bit_uint()), #4213-MSB
('Name7', decoder.decode_8bit_uint()), #4213-LSB
])
elif (addr == 4213):
decoded = OrderedDict([
('CTIME0', decoder.decode_32bit_uint()), #4214+#4215
('CTIME1', decoder.decode_32bit_uint()), #4216+#4217
('CTIME2', decoder.decode_32bit_uint()), #4218+#4219
])
elif (addr == 4243):
decoded = OrderedDict([
('VbattRegSetPTmpComp', decoder.decode_16bit_int()/10.0), #4244
('nominalBatteryVoltage', decoder.decode_16bit_uint()), #4245
('endingAmps', decoder.decode_16bit_int()/10.0), #4246
('skip', decoder.skip_bytes(56)), #4247-4274
('ReasonForResting', decoder.decode_16bit_uint()), #4275
])
elif (addr == 16386):
decoded = OrderedDict([
('app_rev', decoder.decode_32bit_uint()), #16387, 16388
('net_rev', decoder.decode_32bit_uint()), #16387, 16388
])
return decoded
# --------------------------------------------------------------------------- #
# Get the data from the Classic.
# Open the cleint, read in the register, close the client, decode the data,
# combine it and return it
# --------------------------------------------------------------------------- #
modbusClient = None
isConnected = False
def getModbusData(modeAwake, classicHost, classicPort):
global isConnected, modbusClient
try:
if not isConnected:
log.debug("Opening the modbus Connection")
if modbusClient is None:
modbusClient = ModbusClient(host=classicHost, port=classicPort)
#Test for successful connect, if not, log error and mark modbusConnected = False
modbusClient.connect()
if MODBUS_VERSION == 2:
result = modbusClient.read_holding_registers(4163, 2, unit=10)
else:
result = modbusClient.read_holding_registers(4163, 2, slave=10)
if result.isError():
# close the client
log.error("MODBUS isError H:{} P:{}".format(classicHost, classicPort))
modbusClient.close()
isConnected = False
return {}
isConnected = True
theData = {}
#Read in all the registers at one time
theData[4100] = getRegisters(theClient=modbusClient,addr=4100,count=44)
theData[4360] = getRegisters(theClient=modbusClient,addr=4360,count=22)
theData[4163] = getRegisters(theClient=modbusClient,addr=4163,count=2)
theData[4209] = getRegisters(theClient=modbusClient,addr=4209,count=4)
theData[4213] = getRegisters(theClient=modbusClient,addr=4213,count=6)
theData[4243] = getRegisters(theClient=modbusClient,addr=4243,count=32)
theData[16386]= getRegisters(theClient=modbusClient,addr=16386,count=4)
#If we are snoozing, then give up the connection
#log.debug("modeAwake:{}".format(modeAwake))
if not modeAwake :
log.debug("Closing the modbus Connection, we are in Snooze mode")
modbusClient.close()
isConnected = False
except: # Catch all modbus excpetions
e = sys.exc_info()[0]
log.error("MODBUS Error H:{} P:{} e:{}".format(classicHost, classicPort, e))
try:
modbusClient.close()
isConnected = False
except:
log.error("MODBUS Error on close H:{} P:{}".format(classicHost, classicPort))
return {}
log.debug("Got data from Classic at {}:{}".format(classicHost,classicPort))
#Iterate over them and get the decoded data all into one dict
decoded = {}
for index in theData:
decoded = {**dict(decoded), **dict(doDecode(index, getDataDecoder(theData[index])))}
# Device type 251 is different
if decoded['Type'] == 251:
decoded['Type'] = '250 KS'
# IP number
decoded['IP'] = classicHost
# Charge State icon
decoded['ChargeStateIcon'] = 'mdi:music-rest-whole'
if decoded['ChargeStage'] == 3 or decoded['ChargeStage'] == 4:
decoded['ChargeStateIcon'] = 'mdi:battery-charging'
elif decoded['ChargeStage'] == 5 or decoded['ChargeStage'] == 6:
decoded['ChargeStateIcon'] = 'mdi:format-float-center'
elif decoded['ChargeStage'] >= 7:
decoded['ChargeStateIcon'] = 'mdi:approximately-equal'
#
chrg_stt_txt_arr = {
0: 'Resting',
3: 'Absorb',
4: 'Bulk MPPT',
5: 'Float',
6: 'Float MPPT',
7: 'Equalize',
10: 'HyperVOC',
18: 'Equalize MPPT',
}
decoded['ChargeStateText'] = chrg_stt_txt_arr[decoded['ChargeStage']]
# SOC icon
SOCicon = "mdi:battery-"
if decoded["ChargeStage"] == 3 or decoded["ChargeStage"] == 4:
SOCicon = SOCicon + "charging-"
SOCicon = SOCicon + str( int( int(decoded["SOC"]) / 10 ) ) + "0"
if SOCicon == "mdi:battery-100":
SOCicon = "mdi:battery"
decoded["SOCicon"] = SOCicon
# Rest reason
rest_reason_arr = {
1: "Anti-Click. Not enough power available (Wake Up)",
2: " Insane Ibatt Measurement (Wake Up)",
3: " Negative Current (load on PV input ?) (Wake Up)",
4: " PV Input Voltage lower than Battery V (Vreg state)",
5: " Too low of power out and Vbatt below set point for > 90 seconds",
6: " FET temperature too high (Cover is on maybe?)",
7: " Ground Fault Detected",
8: " Arc Fault Detected",
9: " Too much negative current while operating (backfeed from battery out of PV input)",
10: "Battery is less than 8.0 Volts",
11: "PV input is available but V is rising too slowly. Low Light or bad connection(Solar mode)",
12: "Voc has gone down from last Voc or low light. Re-check (Solar mode)",
13: "Voc has gone up from last Voc enough to be suspicious. Re-check (Solar mode)",
14: "PV input is available but V is rising too slowly. Low Light or bad connection(Solar mode)",
15: "Voc has gone down from last Voc or low light. Re-check (Solar mode)",
16: "Mppt MODE is OFF (Usually because user turned it off)",
17: "PV input is higher than operation range (too high for 150V Classic)",
18: "PV input is higher than operation range (too high for 200V Classic)",
19: "PV input is higher than operation range (too high for 250V or 250KS)",
22: "Average Battery Voltage is too high above set point",
25: "Battery Voltage too high of Overshoot (small battery or bad cable ?)",
26: "Mode changed while running OR Vabsorb raised more than 10.0 Volts at once OR Nominal Vbatt changed by modbus command AND MpptMode was ON when changed",
27: "bridge center == 1023 (R132 might have been stuffed) This turns MPPT Mode to OFF",
28: "NOT Resting but RELAY is not engaged for some reason",
29: "ON/OFF stays off because WIND GRAPH is illegal (current step is set for > 100 amps)",
30: "PkAmpsOverLimit… Software detected too high of PEAK output current",
31: "AD1CH.IbattMinus > 900 Peak negative battery current > 90.0 amps (Classic 250)",
32: "Aux 2 input commanded Classic off. for HI or LO (Aux2Function == 15 or 16)",
33: "OCP in a mode other than Solar or PV-Uset",
34: "AD1CH.IbattMinus > 900 Peak negative battery current > 90.0 amps (Classic 150, 200)",
35: "Battery voltage is less than Low Battery Disconnect (LBD) Typically Vbatt is less than 8.5 volts",
104: "104?=14?: PV input is available but V is rising too slowly. Low Light or bad connection(Solar mode)",
}
try:
decoded["ReasonForRestingText"] = rest_reason_arr[decoded["ReasonForResting"]]
except:
log.error("ReasonForRestingText Error ")
return decoded