Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Polyphonic recording sends wrong gates and too many notes when monitoring. #43

Closed
jsmonzani opened this issue May 23, 2020 · 3 comments
Closed

Comments

@jsmonzani
Copy link

Melody and Timeling sends wrong polyphonic gates on output while recording (i.e. : recorded gates / notes + gates / notes from the timeline).

Please check the included patch.
https://drive.google.com/file/d/1tkcMsj3mBm69XwVa6bT0x4GrhpUIvjaV/view?usp=sharing

While recording multiple notes, whenever a gate is on/off, it is sent to all hold notes. So it's a problem when recording and monitoring it.

The top Melody is the player. If you listen to the melody, it works fine: C, then E, then G

Now, try to hit Record on the bottom Melody: whenever a note is triggered or released, ALL other notes are retriggered. You can check the channels and notice that more than 3 channels become active. So you get C, then C+E as if they were hit together, then C+E+G as hit together.

Thank you

@jsmonzani jsmonzani changed the title Polyphonic recording sends wrong gates when monitoring. Polyphonic recording sends wrong gates and too many notes when monitoring. May 23, 2020
@RichieHindle
Copy link

Thanks for the detailed bug report! This bug is fixed, and the fix will be in the next release of Entrian Sequencers, due in the next week or so.

@jsmonzani
Copy link
Author

Wonderful! Thank you!

@EntrianAudio
Copy link
Owner

Now in the VCV Library, version 1.1.16.

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Labels
None yet
Projects
None yet
Development

No branches or pull requests

3 participants