Basic frame structure

Offset Function
1 - 2 Frame header
3 Address
4 - 5 Data
6 Checksum

Checksums

The checksum is calculated as the byte sum (mod 256) of the frame address and data (see: AtyMain.java#L365-L379)

byte checksum = (byte)((address + data[0]) + data[1]); 

Frame headers

Header Function
A5A5 Write data/params to BMS
5A5A Read data/params from BMS
DBDB Write data to the screen/main (?) board

Live data

Used in AtyParam2.java.

Bluetooth: Send 0xDBDB00000000 - Returns 140 bytes of data
BMS serial port: Send 0x5A5A00000000

Offset Function Type Unit
0 - 3 Frame Header 0xAA 0x55 0xAA 0xFF
4 - 69 Voltage data 0.000 V
70 - 73 Current int 0.0 A
74 Percentage of remaining battery u8
75 - 78 Battery physical capacity u32 .000000 AH
79 - 82 The remaining battery capacity u32 .000000 AH
83 - 86 Total battery cycle capacity u32 .000AH
87 - 90 Accumulated from boot time seconds u32 S
91 - 102 Actual temperature short degree
103 Charge mos tube status flag u8 (after analysis)
104 Discharge mos tube status flag u8 (after analysis)
105 Balanced status flag u8 (resolved below)
106 - 107 Tire length u16 MM
108 - 109 The number of pulses per week u16 N
110 Relay switch u8 does not show
111 - 114 Current Power int W
115 Maximum number of monomer strings u8 None
116 - 117 The highest monomer u16 0.000V
118 Lowest monomer string u8 None
119 - 120 Lowest monomer u16 0.000V
121 - 122 Average u16 0.000V
123 The number of effective batteries u8 S
124 - 125 Detected discharge tube Voltage between D-S poles u16 0.0V not to be displayed
126 - 127 Discharge MOS transistor driving voltage u16 0.0V not display
128 - 129 Charging MOS tube driving voltage u16 0.0V not display
130 - 131 When the detected current is 0, the comparator initial value
Control equalization corresponds to 1 equalization
u16 is not displayed
132 - 135 (1 - 32 bits corresponds to 1 - 32 string equalization)
corresponds to bit 1 displays the color at the corresponding voltage
u32
136 - 137 The system log is sent to the serial port data
0 - 4: Status
5 - 9: Battery number
10 - 14: Sequential order
15: Charge and discharge (1 discharge, 0 charge)
u16
136 - 137 System logs
138 - 139 Sum check 2 bytes

Checksum

The checksum is calculated as the sum of all data bytes at offsets 4 to 137 and will be verified as follows (see: BcService.java#L277-L286):

int expected = 0;
for (i = 4; i < 138; i++) {
    expected += data[i];
}

int checksum = (data[138] << 8) + data[139]; // big endian
if (checksum == expected) {
    // checksum valid
} else {
    // checksum invalid
}

Charge MOSFET status flag

Value Type
0 Off
1 Open
2 Overvoltage protection
3 Over current protection
4 battery full
5 total overpressure
6 battery over temperature
7 power over temperature
8 Abnormal current
9 Balanced line dropped string
10 motherboard over temperature
13 Discharge tube abnormality
15 Manually closed

Discharge MOSFET status flag

Value Type
0 Off
1 Open
2 Over-discharge protection
3 Over current protection
5 Total pressure undervoltage
6 Battery over temperature
7 Power over temperature
8 Abnormal current
9 Balanced line dropped string
10 Motherboard over temperature
11 Charge on
12 Short circuit protection
13 Discharge tube abnormality
14 Start exception
15 Manually closed

Balancing status flag

Value Type
0 Off
1 Exceeds the limit equilibrium
2 Charge differential pressure balance
3 Balanced over temperature
4 Automatic equalization
10 Motherboard over temperature

Control addresses

Address Type Notes
247 Close BMS power
248 Current zeroing
249 Discharge MOS tube switch
Forced to close the discharge tube
Data is 0
250 Charge MOS tube switch
Forced shutdown charge officer
Data is 0
251 Change the parameter to iron lithium
252 The battery is automatically balanced
253 Factory Settings button
254 Reboot button
255 Apply button

Parameter addresses

AtyParam.java uses this parsing

Address Type
1 Monomer over-voltage alarm voltage
2 Single undervoltage warning voltage
3 Single overvoltage protection voltage
4 Single undervoltage protection voltage
5 Monomer overvoltage recovery
6 Monomer undervoltage recovery
7 Total voltage overvoltage protection voltage
8 Total voltage undervoltage protection voltage
9 Charge Overcurrent Protection 000.0A
10 Charging Overcurrent Protection Delay Seconds
11 Discharge Overcurrent Protection
12 Discharge Overcurrent Protection Delay Seconds
13 Equilibrium voltage limit
14 Equilibrium starting voltage during charging
15 Equal pressure difference
16 Equilibrium current value (1-20)
17 System Voltage Reference
18 Current sensor range
19 Start Current (A)
20 Short Circuit Protection Current (A)
21 Short circuit protection delay (us)
22 No current automatic standby time (seconds)
23 Total voltage AD value is 0000 (4-digit integer)
(is converted into the actual voltage value parameter)
24 Set the number of battery strings
25 Battery high temperature charge protection
26 Battery High Temperature Charge Recovery
27 Battery High Temperature Discharge Protection
28 Battery High Temperature Discharge Recovery
29 Power tube high temperature protection
30 Power tube high temperature recovery
31 - 32 Battery Physical Capacity .000 000AH (2 Spaces) (76 Low, 77 High)
33 - 34 remaining capacity .000 000AH (2 spaces) (78 low, 79 high)
35 - 36 Total circulation capacity .000AH (2 spaces) (80 low, 81 high)
41 Tire length
42 Number of pulses per week
51 - 74 Battery internal resistances
100 Runtime (70 - 71 two spaces)