Skip to content

collects voltage data from individual cells in multicell battery pack

Notifications You must be signed in to change notification settings

gregsell/arduino-multicell-battery-monitoring

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 

History

6 Commits
 
 
 
 

Repository files navigation

arduino-multicell-battery-monitoring

collects voltage data from individual cells in multi-cell battery pack using the internal 10-bit ADC of the Arduino Uno

description

When analyzing old multi-cell battery packs this tool helps to find malicious cells by monitoring all individual cell voltages simultaneously - also during load. By finding and replacing these cells with a conspicious drop in voltage the battery should become more capable again.

setup

I used an Arduino Uno and its internal ADC. (Not optimal regarding its 10 bit resolution) Apart from that there are no constraints, use an external ADC unit in combination with a noise free power supply - if possible.

As the internal 10-bit 6 channel ADC of the Uno can measure only absolute voltages from 0 - 5V, external voltage dividers have to be used. These should be selected in a way so that as much as possible of the ADC range can be used to not loose 'resolution', i.e. aim for the max voltage to be near 5V. (Applies also to other microcontrollers/external ADCs, although the respective logic voltage might be 3.3V) The factor by which the voltage is reduced has to be carefully measured externally (DMM) and adjusted for afterwards.

how the software works

The code is array-based to be as dynamic as possible. In the current form only cells in series are supported, but using a two-dimensional array this could easily be adapted. The voltages are printed to the serial monitor and can then be copied to excel or similar to be graphed out. (Note that the current Arduino IDE 2.2.1 has this bug where copying everything from the serial monitor is not possible, the legacy version 1.8x works though)

limitations

  • many analog inputs needed
  • Readings can become noisy very fast
  • As the voltages of the 'higher' cells are analytically deduced by subtracting those below, errors sum up.