ABCC SPI Analyzer Plugin Reference

This wiki page is meant to be a mirror copy of the content provided in the release's quick start guide.


Feature List

The ABCC SPI Protocol Analyzer Plugin consists of the following features:

  • Multi-layered framing of ABCC SPI fields
  • 3-wire or 4-wire SPI support
  • Indexed and searchable results (with analyzer filter options) for:
    • Network timestamp (with packet counter)
    • Anybus Status change events
    • Application Status change events
    • Error events (logical or protocol-wise)
      • Error response messages
      • Exception codes and information
      • Application error status events
      • Anybus error status events
      • Fragmented packets or clocking error events
      • CRC32 error events
      • Retransmissions (partial support)
      • Buffer full (warning event)
    • New messages (response, command, error response) with support for indication of SPI message fragmentation protocol and message segmentation.
  • Analyzer export options (uses CSV format with ’,’ delimiter by default)
    • Export of:
      • All frame data
      • All message data
      • All process data
  • Simulation mode
    • Standard simulation
      • Produces a file object communication with various random events including error events.
      • Conveys plugin's version information.
    • ABCC SDK log file simulation
      • Generate a sequence of SPI packets conveying object messaging and Anybus status information.
    • User configurable options for modifying underlying signaling, timing, and messaging characteristics.

System Requirements

Recommended

  • Saleae Logic (software)
    • Recommended Version: 1.2.29
    • Other versions will work so long as it is compatible with Logic SDK version 1.1.32.
    • NOTE: At this time, Saleae Logic V2 is not supported.
  • Saleae Logic analyzer (hardware)
  • Operating system
    • Windows 7 through Windows 10
      • NOTE: At this time Window 11 has compatibility issues with version 1.2.29. Version 1.2.40 resolves this compatibility issue but Saleae dropped support for the decoded protocols subwindow for this version. An alternative solution for using 1.2.29 on Windows 11 would be to use WSLg and attach the Saleae Logic interface via usbpid.exe. See How-To: Connect USB devices.
    • Apple OS X 10.7 Lion+ (or macOS)
    • Ubuntu 12.04.2+
  • Precompiled ABCC SPI Analyzer plugin

Installation

To install this plugin, it is assumed that the user has previously installed the Saleae Logic software using the default installation options. It is also assumed the default installation path is used (where applicable). Copy the corresponding plugin source to the indicated destination path for the operating system being used as indicated in the table below.

OS Plugin source Destination Path
Windows 64-bit .\plugins\Win64\AbccSpiAnalyzer64.dll C:\Program Files\Saleae LLC\Analyzers\
Windows 32-bit .\plugins\Win32\AbccSpiAnalyzer.dll C:\Program Files\Saleae LLC\Analyzers\
Linux 64-bit (Ubuntu) .\plugins\Linux64\AbccSpiAnalyzer64.so .\Analyzers folder of the Logic software installation path
Linux 32-bit (Ubuntu) .\plugins\Linux32\AbccSpiAnalyzer.so .\Analyzers folder of the Logic software installation path
macOS (OSX) .\plugins\OSX\AbccSpiAnalyzer64.dylib .\Analyzers folder of the Logic software installation path

Plugin Overview

Running the Analyzer

If properly installed, the analyzer will appear in the “Analyzers” sub-window’s “add” option (+) as shown in the figure below.

Adding the analyzer

After the analyzer has been selected, the settings window will be displayed as shown in the figure below. The default indexing options provide the most basic and, perhaps, the most commonly used options, but can be changed according to the user’s needs.

Plugin settings

Select the corresponding channels that are associated with the physical MOSI, MISO, Clock (SCLK), and Enable (CS/SS) lines to the ABCC. The enable channel is optional and will function in 3-wire mode if set to ‘None’.

IMPORTANT NOTE: When using the plugin in “3-wire” mode there are minimum “idle gap” and maximum “clock idle high” timing requirements (>10us and <5us respectively). Also, the ABCC’s 3-wire SPI mode only supports “clock idle high” configuration and is enforced in the analyzer logic in such a configuration. See discussion on “Advanced Settings” for details on how to analyze 4-wire without monitoring the enable signal.

Plugin overview


Framing (Bubble-Text)

Each of the bubble-text frames (a term used by the Saleae Logic SDK that refers to the blue bars seen in the software) correspond to fields within an ABCC SPI packet. When applicable, these fields are processed and converted into human readable enumerations of the flags and values that make up the underlying ABCC communication. For instance, the bubble text frame shown in the figure below shows “ANB_STS: (PROCESS_ACTIVE | SUP)”. This indicates that the ABCC is in the process active state and is being supervised.


Multi-Layer Bubble Text

The figure below illustrates the multi-layered bubble text that the plugin supports. This example shows how the SPI Control field looks when zoomed out, and how it may look when sufficiently zoomed-in, revealing more verbose information about the state of the field. Additionally, when sufficiently zoomed-in, the logic signal will be drawn with ‘0’ and ‘1’ indicators over the exact sample point in the corresponding channel which reflect the state of the signal during that sample period.

Multi-layered bubble text

To determine if the last, most detailed, bubble-text is currently being displayed the user can make the following observations:

  • All frames will contain a single-character bubble-text entry
    • This character will either be the first character of the “tag” or an “alert” represented by ‘!’.
    • The currently used tag names are defined in the following section.
  • All frames will contain a “tag” bubble-text entry
    • This entry is meant to be short but readable enough for the user to determine its meaning when sufficiently familiar with the ABCC SPI telegram fields.
    • In the case of an “alert”, the tag will be prefixed by “!ALERT -“.
  • All frames will contain a “value”
    • This value will use an appropriate “display radix” option for a given field. Fields that are naturally numeric values will not be permitted to display as a ”character” value and will restrict to using hex-format when the user sets the ”display radix” option as ASCII from the Logic software.
  • Optionally, frames may contain a descriptive/enumerated bubble-text entry
    • A user can reasonably determine if there are deeper levels of bubble-text available by the presence of parenthesis or square brackets encapsulating the information following the “tag”. A “tag” and the information that follows is always separated by a colon ‘:’.

Tag Descriptions

Tag Name Additional Details
!ALERT Alert Indicator Prepended to another tag as indicator of important events (commonly to signal an error of some kind)
FRAG Fragmented Packet Indication of an incomplete ABCC SPI packet detected.
SPI_CTL SPI Control Field (MOSI) SPI control byte
RES Reserved Field -
MSG_LEN Message Data Length Field (MOSI) Length in WORDs (16-bit) of the "Message Data Field"
PD_LEN Process Data Length Field (MOSI) Length in WORDs (16-bit) of the "Process Data Field"
LED_STS LED Status Field (MISO) LED status
ANB_STS Anybus Status Field (MISO) Anybus status
SPI_STS SPI Status Field (MISO) SPI status
APP_STS Application Status Field (MOSI) Application status
INT_MSK Interrupt Mask Field (MOSI) Mask specifies which interrupt events are generated by the module.
TIME Network Time Field (MISO) Network time reported from the module
MSG_SIZE Message Size Field Size of the message data in bytes. This corresponds to the actual payload of the message which may exceed MSG_LEN, in which case message fragmentation is used.
SRC_ID Message Source ID Source ID for a message transaction
OBJ Object Host/Module object being accessed
INST Instance Instance of the object being accessed
CMD Command Message Message contains a command.
RSP Response Message Message contains a response.
ERR_RSP Error Response Message Message contains an error response. Error code is present in message data.
EXT Command Extension 16-bit Command extension data.
MD Message Data Valid message data (message data byte offset < message size)
EXC_INFO Exception Information Network-specific exception information
EXC_CODE Exception Code Exception code (Reported by Anybus or functional safety module object)
ERR_CODE Error Response Code Indication of an Error Response Code (first byte)
OBJ_ERR Object-Specific Error Code Indication of an Object-Specific Error Response Code (second byte)
NW_ERR Network-Specific Error Code Indication of a Network-Specific Error Response Code (third byte)
-- Data Not Valid Indication of "data not valid". Used in leftover message data.
PD Process Data Indicates either read/write process data
CRC32 CRC32 Checksum 32-Bit CRC of the channel's SPI data
PAD Pad Field (MOSI) Dummy Data

Markers

Each analyzer plugin is responsible for drawing their own markers onto channels; this is an optional feature of a plugin which can be used in a variety of ways to provide higher-level/at-a-glance understanding of a capture or finely detailed indication of events. This plugin uses markers in both ways; the usage of each marker is described below.

Marker SDK Name Applicable Channels Usage
start marker Start Enable Used to indicate an ABCC message command
stop marker Stop Enable Used to indicate an ABCC message response (no error)
dot marker Dot Enable Used to indicate ABCC message fragmentation
square marker Square Enable Used to indicate that multiple events have occurred (no errors)
x marker X Enable Used to indicate one of the following protocol events occurred: Anybus status change (including error and exception states), message buffer full, application status change, SPI packet retransmission
error dot marker Error Dot Enable Used to signal an ABCC error response message.
error square marker Error Square SCLK, Enable On SCLK: Used to indicate a clocking/protocol violation. On Enable: Used to indicate that multiple events have occurred with at least one error event.
error x marker Error X Enable Used primarily to indicate an error in the CRC32 field or to signal that a packet has been ”cancelled” from further processing due to a byte acquisition error.
up arrow marker Up Arrow SCLK Used to indicate the clock sample phase.
one marker One MOSI, MISO Used to indicate the sample point fed into the byte acquisition logic. In this case a logic ’1’ was read.
zero marker Zero MOSI, MISO Used to indicate the sample point fed into the byte acquisition logic. In this case a logic ’0’ was read.

Note: To help with locating the actual error event, “error markers” (dots, squares, or x’s are placed on the Slave Select signal where the beginning of the bubble-text frame associated with the error event occurred. The current version of Saleae Logic software has some issues with resolving markers that are drawn in close proximity to each other. To mitigate this issue as much as possible, such markers are relocated to the slave select line to help maximize the likelihood that the marker will be drawn on the screen. Ideally, a future update of the Logic software would remove this limitation. In such an event, these markers may be relocated to reside on the physical channel where the error event was detected.


Analyzer Settings Window

The figure below shows the default state of the analyzer settings.

Plugin settings

Network Type

This option allows the plugin to have an awareness of the network type which makes it possible to report network specific details. For example, this feature is used to provide the instance name of each instance in the Network Configuration object. The default state of this option is “Unspecified”.

Index - Errors

When enabled, this option will index each “error” event. The default state of this option is “enabled”. To make searching for issues as easy as possible, all error events are prefixed with “!”. An error is classified as any of the following:

  • Protocol Fragmentation
    • Not to be confused with ABCC SPI fragmentation protocol. This error is indicated when Slave-Select de-asserts before a complete ABCC transaction completes.
  • SPI Clocking Errors
  • Error Response Messages
  • Application Status is in an “error state”
  • Anybus Status is in an “error state”

Index – Network Timestamp

When enabled, this option will index each “network timestamp” received from the MISO ABCC message. The default state of this option is “disabled”.

Index - Anybus Status

When enabled, this option will index each “Anybus status event” received from the MISO ABCC message. The default state of this option is “disabled”. Even when disabled, if error indexing is enabled, any Anybus state related to an error/exception will be indexed.

Index - Application Status

When enabled, this option will index each “Application status event” received from the MISO ABCC message. The default state of this option is “disabled”. Even when disabled, if error indexing is enabled, any application state related to an error/exception will be indexed.

Index - Message

When enabled, this option will index each “New message” in the “Decoded Protocols” sub-window. Retransmissions, commands, and (error) responses all fall into this category. This setting can be set to “compact”, “verbose”, or “disabled”. The default state of this option is “verbose”.

Verbose

Verbose decoding

Compact
Entry MOSI-Obj {03:0001h}, Cmd {01:0003h}
Meaning A new message for object 0x03 (Network object) instance 0x0001 with command byte 0x01 (Get_Attribute) for attribute 0x03 (Data format). To keep things compact (since the Saleae Logic software does not have a resizable decodes window) the message fields are represented in the decoded section as raw hexadecimal format.
Entry MISO-Obj {03:0001h}, Rsp {01:0003h}
Meaning This message is identical to the previous example except that it represents a response message. Notice that the bit-field (within the command byte) responsible for indication of whether a message contains a command or a (error) response is filtered from the raw value here. This is done to improve the flexibility of searching the decoded results.
Entry MOSI-Obj {F8:0001h}, Cmd {01:0006h}++
Meaning Like the previous example this indicates a new message. The presence of “++” at the end of the entry indicates that this is message is using the ABCC’s SPI fragmentation protocol.
Entry MOSI-{Message Fragment}++
Meaning Indicates the corresponding message data is a continuation of the ABCC’s SPI fragmentation protocol. The presence of “++” at the end of the entry indicates that this is message is not the “Last Fragment”. An example of this is shown in the figure below.

Compact decoding

Message Data Priority

This option allows the user to prioritize either the “tag” or the “data” for each message data bubble-text entry.

  • “Prioritize Tag”
    • Use this option when only interested in knowing where the message data begins and ends within the telegram.
  • “Prioritize Data”
    • Use this option when interested in seeing each adjacent message data byte.

Process Data Priority

This option allows the user to prioritize either the “tag” or the “data” for each process data bubble-text entry.

  • “Prioritize Tag”
    • Use this option when only interested in knowing where the process data begins and ends within the telegram.
  • “Prioritize Data”
    • Use this option when interested in seeing each adjacent message data byte.

Advanced Settings

This option can specify an external XML configuration file that contains extra options that may be useful in certain situations. Below is the "Advanced Settings" XML template which provides a full description of each available option.

The default state of this setting is an empty file path string (this means the default state of the advanced settings will be used). The default state of each setting is summarized in the tables found below.

<?xml version="1.0" encoding="utf-8"?>
<AdvancedSettings>

   <!-- "4-wire-on-3-channels" is useful when a 4-wire SPI configuration is used to interface with
   the ABCC but only MOSI, MISO, and SCLK are connected to the Logic analyzer. This mode will
   ignore timing and CPOL/CPHA requirements that the ABCC's 3-wire mode enforces. -->
   <Setting name="4-wire-on-3-channels">0</Setting>

   <!-- "3-wire-on-4-channels" is useful when a 3-wire SPI configuration is used to interface with
   the ABCC but the user has a spare Logic channel that can be used as a dummy place holder for
   placing the markers that the plugin normally applied to the SPI Enable channel. -->
   <Setting name="3-wire-on-4-channels">0</Setting>

   <!-- "export-delimiter" allows the user to define a delimiter to use when using one of the
   plugin's supported export options. Any single (visible) character is accepted as a delimiter.
   A tab-delimiter can be specified by using "\t" without the quotes. -->
   <Setting name="export-delimiter">,</Setting>

   <!-- "clocking-alert-limit" provides the user with a way to restrict how many times a
   "clocking alert" event will be reported by the plugin. This can be useful in cases where a
   device's SPI chipselect line may "appear" to toggle at the same time the SPI clock transitions
   high after receiving the last bit in the SPI transaction. This event results in a
   "clocking alert" notification. This type of event is more of an informational warning/error
   event, and as long as the user understands the reason and deems the behavior acceptable, then
   this setting may be set to a value >=0. Setting the value to 0 disables the notification
   entirely. While any value above zero (datatype is S32) will set a maximum count for producing
   the notification in the processed results. An invalid value or value <0 indicates that there is
   no limit. Users of the ABCC StarterKit may encounter this scenario since the chipselect line is
   deasserted close in time (~8ns) with the SPI clock returning to the "clock idle high" state.
   This results in a higher than normal sampling time requirement to resolve the two events
   occurring at different points in time. Sampling more than 125MSamples/second is necessary to
   avoid this issue; thus, a general recommendation for this scenario is to use sampling rates of
   250MS/s or higher. If this is not possible due to hardware limitations of the PC/analyzer then
   it is recommended to set this parameter to a value >= 0 to limit how many times the error is
   reported. -->
   <Setting name="clocking-alert-limit">-1</Setting>

   <!-- "expand-bit-frames" provides a workaround for a limitation found in Saleae Logic software
   version 1.2.x. Specifically, the software does not properly navigate to the associated bubble
   text entry when clicking on a "Decoded Protocols" entry for a frame less than 8 samples.
   Currently, this workaround is only applicable for error frames; any error frame less than 8
   samples will be expanded to 8 samples to restore the linkage. This feature could have
   undesirable side effects in rare circumstances. In case of abnormal behavior it may be necessary
   to disable this feature. -->
   <Setting name="expand-bit-frames">1</Setting>

   <!-- "simulation" provides various options for generating simulated ABCC SPI communication.
   There are two primary modes supported: "standard simulation" and "log file simulation".
   "Standard simulation" involves a general hardcoded procedure for file object communication. This
   simulation functions on various pseudorandom number generators for randomly creating different
   events including various error events. This mode also conveys the plugin's version information.
   "Log file simulation" involves parsing a standard ABCC SDK log file and generating ABCC
   SPI packets that convey these messages. The SDK message logging is activated via
   ABCC_CFG_DEBUG_MESSAGING in abcc_drv_cfg.h. The target platform must have support for
   ABCC_PORT_DebugPrint() in abcc_sw_port.h. -->
   <Setting name="simulation">
      <!-- Path to the log file to simulate. No quotes, backslash/forward slashes are acceptable.
      Empty or invalid paths will disable "log file simulation" and instead "standard simulation"
      mode will be executed. -->
      <LogFilePath></LogFilePath>

      <!-- Default ABCC state (integer) for "log file simulation". Use one of the raw values
      specified in ABP_AnbStateType. Invalid values will default to SETUP state. -->
      <LogFileDefaultAnbState>0</LogFileDefaultAnbState>

      <!-- SPI clock polarity setting (integer). 0 = Clock Idles Low, 1 = Clock Idles High,
      Else = "Auto-mode". "Auto-mode" changes behavior depending on simulation mode. When running
      "log file simulation", auto-mode will use clock-idle-high for 3-wire mode, and clock-idle-low
      for 4-wire mode. When running "standard simulation" mode, auto-mode will use a pseudorandom
      number generator to toggle between clock-idle-high and clock-idle-low to illustrate both modes
      in one simulation run. NOTE: The ABCC's 3-wire mode only supports clock-idle-high, while in
      3-wire mode clock-idle-high will be enforced. -->
      <SpiClockIdleHigh>-1</SpiClockIdleHigh>

      <!-- SPI clock frequency (integer, in Hertz). Values <= 0 or parsing errors will default to
      auto-frequency (this is a mode where the SPI clock frequency is set, when possible, to
      1/10th the sampling frequency). Values > 20MHz will be limited to 20MHz. 3-wire mode will
      enforce a minimum of 100KHz. Please keep in mind the analyzer's configured sample rate, this
      mode of simulation requires the user to consider Nyquist rate just like in real world logic
      analyzer usage. -->
      <SpiClockFrequency>0</SpiClockFrequency>

      <!-- SPI inter-packet gap (integer, in nanoseconds). Values <= 0 or parsing errors will
      default to 15000ns. -->
      <SpiPacketGapNs>0</SpiPacketGapNs>

      <!-- SPI inter-byte gap (integer, in nanoseconds). Values < half the SPI clock period or
      parsing errors will default to half the SPI clock period. -->
      <SpiByteGapNs>0</SpiByteGapNs>

      <!-- SPI spacing between chip-select going active-low and the first clock edge and the
      spacing after the last clock edge before chip-select returns high (integer, in nanoseconds).
      Note, depending on SPI configuration the spacing on one side will have an additional 1/2
      clock period delay. Values <= 0 or parsing errors will default to 1000ns. -->
      <SpiChipSelectDelayNs>0</SpiChipSelectDelayNs>

      <!-- SPI register data size (in bits). This parameter represents the underlying SPI
      controller register data size and is used to determine when to apply "SpiByteGapNs".
      This value must be 8 or 16 bits; other values or parsing errors will default to 8 bits. -->
      <SpiDataSize>0</SpiDataSize>

      <!-- Configures the message data length field (in words). {size} = 0: 8 words (default),
      0 < {size} <= 762: fixed message data length, {size} < 0: dynamic mode. When in SETUP,
      NW_INIT, or WAIT_PROCESS, "dynamic mode" will adapt the message field length based on the
      number of message data bytes the host is requesting to send effectively avoiding
      SPI message fragmentation. If the host is not trying to send a message then the message
      channel will default to the absolute value of {size}. While in IDLE or PROCESS_ACTIVE the
      message data length will be set to the absolute value of {size}. When receiving a
      message from the module, the message will be adjusted, if necessary to limit SPI
      message fragmentation. -->
      <SpiMessageDataLength>0</SpiMessageDataLength>
   </Setting>

</AdvancedSettings>

The default state of each setting/sub-setting is indicated in the XML template provided above and also explicitly stated below for convenience. Non-existent XML settings or parsing errors will use the default value.

Setting Datatype Default state Default State Meaning
"4-wire-on-3-channels" BOOL (0/1) 0 Disabled, 3-wire mode will be assumed when omitting the plugin's ENABLE channel
"3-wire-on-4-channels" BOOL (0/1) 0 Disabled, 4-wire mode will be assumed when assigning the plugin's ENABLE channel
"export-delimiter" STRING "," Comma Delimited CSV-files (quotes are not to be included). Only single-character values are accepted. Delimiter must be a visible character. The exception to these two rules is that the user can specify a tab-delimiter via "\t" without the quotes
"clocking-alert-limit" SINT32 -1 Unlimited clocking alert limits
"expand-bit-frames" BOOL (0/1) 1 Error frames < 8 samples will be expanded to 8 samples to restore linkage between "Decoded Protocols" and "Bubble Text".
"simulation" STRUCTURE N/A Contains multiple sub-settings. See "Simulation sub-setting" section below.

Simulation Sub-Setting Datatype Default state Default State Meaning
LogFilePath File Path empty string Invalid or empty log file paths will default to standard simulation mode.
LogFileDefaultAnbState SINT32 0 Invalid values (any value not part of ABP_AnbStateType) will default to 0 (SETUP state).
SpiClockIdleHigh SINT32 -1 Values not equal to 0 or 1 or parsing errors will default to auto-mode.
SpiClockFrequency SINT32 (Hertz) 0 Values <= 0 or parsing errors will default to auto-frequency.
SpiPacketGapNs SINT32 (nanoseconds) 0 Values <= 0 or parsing errors will default to 15000ns.
SpiByteGapNs SINT32 (nanoseconds) 0 Values < half the SPI clock period will default to half the SPI clock period.
SpiChipSelectDelayNs SINT32 (nanoseconds) 0 Values <= 0 or parsing errors will default to 1000ns.
SpiMessageDataLength SINT32 (words) 0 Invalid values or value == 0 will default to 8 words.

Export Options

This plugin supports several options for exporting the captured/processed data. With minimal effort these options make it possible to:

  • Generate process data graphs
    • For instance, the trend of an analog input/output signal could be plotted versus the network time.
    • Analyze jitter characteristics related to the signalling of valid/new input data or receiving new output data.
  • Collect and assemble message data that was sent using SPI fragmentation

Export options

Export All Frame Data

This option will individually export each bubble-text/frame as its own line in a CSV file. This option may be useful to perform additional postprocessing of results in cases where the other two export options may omit desired information.

Export Process Data

This option will export information that is most relevant when considering the SPI process data field. Only SPI packets containing new or valid process data, as indicated by the control/status bytes, will be exported.

Export Message Data

This option will export information that is most relevant when considering the SPI message data field. Only SPI packets containing a message, as indicated by the control/status bytes, will be exported. This option is the ideal choice when the user wants to view a series of object messaging transactions exchanged between the host and module. For instance, a file transfer to/from a File System Interface instance could be captured and easily reassembled into a matching file using the exported capture data for verification purposes. Below is an example of exporting message data during the startup process of the ABCC SDK.

Exported message data


Measurement

The current generation of Saleae Logic hardware adds analog input functionality and can perform basic analog measurements. This helps in spot-checking signal quality when troubleshooting a new hardware design. When using this functionality, keep in mind that the analyzer has anti-aliasing filters which will smooth out the signal and remove out-of-band high frequency content. Sampling around 10x the signal’s frequency is recommended if any precise measurements are required. For more serious analog measurement, a traditional oscilloscope is recommended; however having digitally decoded SPI communication along side of time-correlated analog waveforms can be invaluable when debugging certain signal quality issues.

Measurement of SPI signalling


Troubleshooting

USB Ports

In certain cases, the Logic software may report that it cannot keep up using the current sample rate.

To avoid this scenario, try the following:

  • Reduce the pre-trigger buffer size (found in Options->Preferences->Capture)
  • Reduce the sample rate (as requested by the software)
  • Reduce the capture size
  • Remove/disable unnecessary channels from capture
  • Remove unnecessary USB peripherals from the USB controller that the Logic is connected to.
  • Move the Logic hardware to another USB controller
  • Replace the USB cable with a shorter and/or higher quality cable. Poor signal quality may introduce bit errors across the USB bus and will require retransmission. Such events may fill up the Logic’s buffer which could result in a buffer overrun.
  • Check Saleae Q&A links below for details regarding USB3 host drivers and controllers

System Memory

For the logic to maintain high sampling rates and large capture sizes, the Logic offloads samples into system memory. This means the Logic software increases in RAM utilization with higher sample rates and larger capture sizes. With the current version of the Logic software, the handling of an “out-of-memory” event is less than graceful. When the Logic software runs out of memory, it will simply cash and all unsaved settings or captures will be lost.

To avoid this scenario, try one or more of the following:

  • Reduce capture size
  • Reduce sample rate
  • Remove/disable unnecessary channels from capture
  • Save/Close other capture tabs
  • Close down unnecessary applications that are consuming system memory (see operating system’s task manager for details on utilizations)
  • Upgrade system memory

As a rough estimate, 3 seconds of 4-channel capture data at 50MSamples/second with a host using 10Mbps SPI (4-wire) and approximately 3000 SPI packets per second that is fully processed through the plugin could consume around 1.2GB of RAM. The more logic transitions there are the more memory will be utilized due to the way the analyzer compresses logic data.