forked from cmcgerty/Sofar2mqtt
/
configuration.yaml
218 lines (194 loc) · 6.8 KB
/
configuration.yaml
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
#Sofar ME3000SP Sofar2mqtt sensors
#Updated to now include the new MQTT sensors required for 2022.12 release of Home Assistant onwards
sensor:
- platform: integration
name: Energy_from_battery
source: sensor.inverter_battery_discharge
unit_prefix: k
unit_time: h
method: left
- platform: integration
name: Energy_to_battery
source: sensor.inverter_battery_charge
unit_prefix: k
unit_time: h
method: left
mqtt:
sensor:
- name: "inverter_running_state"
state_topic: "Sofar2mqtt/state"
value_template: >-
{% if value_json.running_state == 0 %}
{{ "0-Standby" }}
{% elif value_json.running_state == 1 %}
{{ "1-Check charge" }}
{% elif value_json.running_state == 2 %}
{{ "2-Charging" }}
{% elif value_json.running_state == 3 %}
{{ "3-Check discharge" }}
{% elif value_json.running_state == 4 %}
{{ "4-Discharging" }}
{% elif value_json.running_state == 5 %}
{{ "5-EPSState" }}
{% elif value_json.running_state == 6 %}
{{ "6-Fault" }}
{% elif value_json.running_state == 7 %}
{{ "7-Perminant Fault" }}
{% else %}
{{ "Undeterminated" }}
{% endif %}
- name: "grid_voltage"
state_topic: "Sofar2mqtt/state"
unit_of_measurement: "V"
device_class: voltage
state_class: measurement
value_template: "{{ value_json.grid_voltage / 10}}"
- name: "grid_current"
state_topic: "Sofar2mqtt/state"
unit_of_measurement: "A"
device_class: current
state_class: measurement
value_template: "{{ value_json.grid_current /100 }}"
- name: "grid_frequency"
state_topic: "Sofar2mqtt/state"
unit_of_measurement: "Hz"
device_class: frequency
state_class: measurement
value_template: "{{ value_json.grid_freq /100 }}"
- name: "grid_power"
state_topic: "Sofar2mqtt/state"
unit_of_measurement: "W"
device_class: power
state_class: measurement
value_template: >-
{% if value_json.grid_power > (65535 / 2) %}
{{ (65535 - value_json.grid_power) * 10 }}
{% else %}
{{ -(value_json.grid_power) * 10 }}
{% endif %}
- name: "inverter_battery_power"
state_topic: "Sofar2mqtt/state"
unit_of_measurement: "W"
device_class: power
state_class: measurement
value_template: >
{% if value_json.battery_power > (65535 / 2) %}
{{ -(65535 - value_json.battery_power) * 10 }}
{% else %}
{{ (value_json.battery_power) * 10 }}
{% endif %}
- name: "inverter_system_power"
state_topic: "Sofar2mqtt/state"
unit_of_measurement: "W"
device_class: power
state_class: measurement
value_template: >
{% if value_json.systemIO_power > (65535 / 2) %}
{{ (65535 - value_json.systemIO_power) * 10 }}
{% else %}
{{ -(value_json.systemIO_power) * 10 }}
{% endif %}
- name: "inverter_battery_discharge"
state_topic: "Sofar2mqtt/state"
unit_of_measurement: "W"
device_class: power
state_class: measurement
value_template: >
{% if (value_json.battery_power > 32767) %}
{{ (65535 - value_json.battery_power) * 10 }}
{% else %}
{{ 0 }}
{% endif %}
- name: "inverter_battery_charge"
state_topic: "Sofar2mqtt/state"
unit_of_measurement: "W"
device_class: power
state_class: measurement
value_template: >
{% if (value_json.battery_power < 32767) %}
{{ (value_json.battery_power) * 10 }}
{% else %}
{{ 0 }}
{% endif %}
- name: "inverter_battery_voltage"
state_topic: "Sofar2mqtt/state"
unit_of_measurement: "V"
device_class: voltage
state_class: measurement
value_template: "{{ value_json.battery_voltage / 100}}"
- name: "inverter_battery_current"
state_topic: "Sofar2mqtt/state"
unit_of_measurement: "A"
device_class: current
state_class: measurement
value_template: "{{ value_json.battery_current /100}}"
- name: "inverter_battery_SOC"
state_topic: "Sofar2mqtt/state"
unit_of_measurement: "%"
device_class: battery
state_class: measurement
value_template: "{{ value_json.batterySOC }}"
- name: "inverter_battery_temp"
state_topic: "Sofar2mqtt/state"
unit_of_measurement: "°C"
device_class: temperature
state_class: measurement
value_template: "{{ value_json.battery_temp }}"
- name: "inverter_battery_cycles"
state_topic: "Sofar2mqtt/state"
state_class: total_increasing
value_template: "{{ value_json.battery_cycles }}"
- name: "house_consumption_power"
state_topic: "Sofar2mqtt/state"
unit_of_measurement: "W"
device_class: power
state_class: measurement
value_template: "{{ value_json.consumption *10 }}"
- name: "solar_power"
state_topic: "Sofar2mqtt/state"
unit_of_measurement: "W"
device_class: power
state_class: measurement
value_template: "{{ value_json.solarPV *10 }}"
- name: "solar_current"
state_topic: "Sofar2mqtt/state"
unit_of_measurement: "A"
device_class: current
state_class: measurement
value_template: "{{ value_json.solarPVAmps }}"
- name: "energy_today_exported"
state_topic: "Sofar2mqtt/state"
unit_of_measurement: "kWh"
device_class: energy
state_class: total_increasing
value_template: "{{ value_json.today_exported /100 }}"
- name: "energy_today_purchase"
state_topic: "Sofar2mqtt/state"
unit_of_measurement: "kWh"
device_class: energy
state_class: total_increasing
value_template: "{{ value_json.today_purchase /100 }}"
- name: "energy_today_consumption"
state_topic: "Sofar2mqtt/state"
unit_of_measurement: "kWh"
device_class: energy
state_class: total_increasing
value_template: "{{ value_json.today_consumption /100 }}"
- name: "energy_today_generation"
state_topic: "Sofar2mqtt/state"
unit_of_measurement: "kWh"
device_class: energy
state_class: total_increasing
value_template: "{{ value_json.today_generation /100 }}"
- name: "inverter_heatsink_temp"
state_topic: "Sofar2mqtt/state"
unit_of_measurement: "°C"
device_class: temperature
state_class: measurement
value_template: "{{ value_json.inverter_HStemp }}"
- name: "inverter_inner_temp"
state_topic: "Sofar2mqtt/state"
unit_of_measurement: "°C"
device_class: temperature
state_class: measurement
value_template: "{{ value_json.inverter_temp }}"