title | description | addedAt | pageClass |
---|---|---|---|
TuYa TS0601_air_quality_sensor control via MQTT |
Integrate your TuYa TS0601_air_quality_sensor via Zigbee2MQTT with whatever smart home infrastructure you are using without the vendor's bridge or gateway. |
2021-10-30 05:58:50 -0700 |
device-page |
Model | TS0601_air_quality_sensor |
Vendor | TuYa |
Description | Air quality sensor |
Exposes | temperature, humidity, co2, voc, formaldehyd, linkquality |
Picture |
How to use device type specific configuration
-
temperature_calibration
: Calibrates the temperature value (absolute offset), takes into effect on next report of device. The value must be a number. -
temperature_precision
: Number of digits after decimal point for temperature, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
humidity_calibration
: Calibrates the humidity value (absolute offset), takes into effect on next report of device. The value must be a number. -
humidity_precision
: Number of digits after decimal point for humidity, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
co2_calibration
: Calibrates the co2 value (absolute offset), takes into effect on next report of device. The value must be a number. -
voc_calibration
: Calibrates the voc value (absolute offset), takes into effect on next report of device. The value must be a number. -
formaldehyd_calibration
: Calibrates the formaldehyd value (absolute offset), takes into effect on next report of device. The value must be a number.
Measured temperature value.
Value can be found in the published state on the temperature
property.
It's not possible to read (/get
) or write (/set
) this value.
The unit of this value is 掳C
.
Measured relative humidity.
Value can be found in the published state on the humidity
property.
It's not possible to read (/get
) or write (/set
) this value.
The unit of this value is %
.
The measured CO2 (carbon dioxide) value.
Value can be found in the published state on the co2
property.
It's not possible to read (/get
) or write (/set
) this value.
The unit of this value is ppm
.
Measured VOC value.
Value can be found in the published state on the voc
property.
It's not possible to read (/get
) or write (/set
) this value.
The unit of this value is ppm
.
The measured formaldehyd value.
Value can be found in the published state on the formaldehyd
property.
It's not possible to read (/get
) or write (/set
) this value.
The unit of this value is mg/m鲁
.
Link quality (signal strength).
Value can be found in the published state on the linkquality
property.
It's not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.
The unit of this value is lqi
.