TomasDJo commented Nov 30, 2022

What happened?

I seem to be unable to set hysteresis lower than 5 degrees.
Zigbee2mqtt shows "Hysterersis setting, range is 5-50, unit is 0.1oC, Default: 5.", this indicate that the adjustment is in 0.1° increments, and the lowest allowed hysteresis value is 0.5°.

The interface indicates that the lowest value of the hysteresis is 5° celcius, and it is increased in 1° increments. This seems to end up in the oven overshooting the setpoint by several degrees. The oven also starts heating way to early (example: temperature sensor reports 17.74° celcius, the oven starts heating as soon as I set the temperature setpoint to 15.5° celcius or above)

What did you expect to happen?

With the lowest hysteresis setting of 0.5°. The oven turns on when it is 0.25° below the setpoint. It turns off when 0.25° above the setpoint.

How to reproduce it (minimal and precise)

Set the temperature to 2.5 degrees below the room temperature with the lowest hysteresis setting. This turns on the oven.

Zigbee2MQTT version

1.28.2

Adapter firmware version

20210120

Adapter

Slaesh CC2652RB

Debug log

No response

@TomasDJo TomasDJo added the problem Something isn't working label Nov 30, 2022
@owangen
Copy link

owangen commented Dec 5, 2022

Is this still an issue with latest z2m release? It should have been fixed with this PR Koenkk/zigbee-herdsman-converters#4918

@TomasDJo
Copy link
Author

TomasDJo commented Dec 5, 2022

It looks to have been fixed in 1.28.4 (the hysteresis setting output in z2m is now showing correctly, and adjustable between 0.5 and 2 degrees). Unfortunately the temperature setting is way off. This is not related to the hysteresis setting according to auduny at #14412 (comment)

@owangen
Copy link

owangen commented Dec 5, 2022

It looks to have been fixed in 1.28.4 (the hysteresis setting output in z2m is now showing correctly, and adjustable between 0.5 and 2 degrees).

Great. Could you close this issue since hysteresis problem is fixed?
The other problem you mentions looks to be from the device it self and cannot be fixed from z2m.

@TomasDJo TomasDJo closed this as completed Dec 5, 2022
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Labels
problem Something isn't working
Projects
None yet
Development

No branches or pull requests

2 participants