Bug Report

What happened

Paired Thermostat
Vendor
Eurotronic
Model
SPZB0001
2 works 2 get Mac error while changing Temperatur via hassio

What did you expect to happen

The thermostat sets the given temperature

How to reproduce it (minimal and precise)

Via Hassio Webfrontend set the Temperatur in Lovelace or via zigbee2mqtt webui change the occupied_heating_setpoint
The following error shows up in logs:

Zigbee2MQTT:error 2020-12-12 08:01:00: Publish 'set' 'occupied_heating_setpoint' to '0x00158d00053d2dd3' failed: 'Error: Write 0x00158d00053d2dd3/1 hvacThermostat({"occupiedHeatingSetpoint":2450}, {"timeout":10000,"disableResponse":false,"disableRecovery":false,"disableDefaultResponse":true,"direction":0,"srcEndpoint":null,"reservedBits":0,"manufacturerCode":null,"transactionSequenceNumber":null}) failed (Data request failed with error: 'MAC no ack' (233))'

ERROR: Publish 'set' 'occupied_heating_setpoint' to 'Badtemperatur' failed: 'Error: Write 0x00158d000369786e/1 hvacThermostat({"occupiedHeatingSetpoint":2400}, {"timeout":10000,"disableResponse":false,"disableRecovery":false,"disableDefaultResponse":true,"direction":0,"srcEndpoint":null,"reservedBits":0,"manufacturerCode":null,"transactionSequenceNumber":null}) failed (Data request failed with error: 'MAC transaction expired' (240))'

The issue describes my problem with different coordinator Hardware
#2500
The given solution isn’t working so I opened a new ticket.

Debug Info

Zigbee2MQTT version: 1.16.2.2
Adapter hardware: CC2652
https://electrolama.com/projects/zig-a-zig-ah/
Adapter firmware version:
{"disable_led":false,"port":"/dev/serial/by-id/usb-1a86_USB2.0-Serial-if00-port0"},"whitelist":[]},"coordinator":{"meta":{"maintrel":1,"majorrel":2,"minorrel":7,"product":1,"revision":20200417,"transportrev":2},"type":"zStack3x0"},

@TIMSCHMITZ TIMSCHMITZ changed the title CC2652, Eurotronic SPZB0001 'MAC no ack' (233))' CC2652, Eurotronic SPZB0001 'MAC no ack' (233))' or MAC transaction expired' (240))' Dec 15, 2020
@jo930
Copy link

jo930 commented Dec 19, 2020

Interesting, I am experiencing what seems to be the same issue: I have 2 Eurotronic SPZB0001, both worked for some time, then one stopped working and when I want to adjust the temperature, I see this error in the log:

ERROR: Publish 'set' 'occupied_heating_setpoint' to 'heater_livingRoom' failed: 'Error: Write 0x00158d00053d3797/1 hvacThermostat({"occupiedHeatingSetpoint":2000}, {"timeout":10000,"disableResponse":false,"disableRecovery":false,"disableDefaultResponse":true,"direction":0,"srcEndpoint":null,"reservedBits":0,"manufacturerCode":null,"transactionSequenceNumber":null}) failed (Data request failed with error: 'MAC transaction expired' (240))'

Also, if I adjust the temperature at the device, it is not reported back to HomeAssistant (it remains unchanged).
I am running Home Assistant 2020.12.0 on a Pi4, Zigbee2mqtt version 1.16.2.2, adapter hardware CC2652 (from slaesh).

@github-actions
Copy link
Contributor

This issue is stale because it has been open 30 days with no activity. Remove stale label or comment or this will be closed in 7 days

@github-actions github-actions bot added the stale Stale issues label Jan 19, 2021
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Labels
stale Stale issues
Projects
None yet
Development

No branches or pull requests

2 participants