Ventilation in respiratorycare #48

Open
DuHao10086 opened this issue Aug 21, 2018 · 1 comment
Open

Ventilation in respiratorycare #48

DuHao10086 opened this issue Aug 21, 2018 · 1 comment

Comments

@DuHao10086
Copy link

DuHao10086 commented Aug 21, 2018

Hi guys,

When I tried to extract ventilation from respiratorycare, there are some cases that ventstartoffset is larger than ventendoffset (e.g. patientunitstayid= 141168). Should we refer to respcarestatusoffset for these cases or exclude? In addition, for cases that ventendoffset=0, are they removed from ventilation when admitted to ICU unit? Thanks.

@alistairewj
Copy link
Member

Please see #49 - just re-raised it from a separate repository that we have deprecated, but haven't fully migrated the issues over yet. This doesn't answer your question but it's important that you consider ventendoffset = 0 as a NULL, and not as an actual time of 0.