Issue description:
I'm trying to show my RF storage with energy screen module from an Induction Matrix from Mekanism and I can't even set the energy module block. It shows 'Energy Module is cleared.'

Steps to reproduce:

  • Have an Induction Matrix, sneak-rightclick energy module.

Versions:

  • Minecraft: 1.12.2
  • Forge: 14.23.5.2846
  • CompatLayer (only if on Minecraft 1.10 or 1.11):
  • McJtyLib: 3.5.4
  • RFTools: 7.73
    Mekanism: 9.8.3.390

Possibly incompatible mods and versions: Optifine(?)

@McJty
Copy link
Collaborator

McJty commented Jan 24, 2020

Does the inducation matrix support RF/FE? Can you (for example) pipe power into it using energy pipes?

@crafian
Copy link
Author

crafian commented Jan 24, 2020

Yes, I tested ThermalExp and EnderIO cables, and a ComputerCraft program all working with RF/FE... There's an image: https://i.imgur.com/woI3Y4f.png

@McJty
Copy link
Collaborator

McJty commented Jan 24, 2020

Well that's weird. You tested if the energy module works with other things?

@crafian
Copy link
Author

crafian commented Jan 24, 2020

Yes, actually working with EnergyCell from ThermalExpansion... I'm very confused

@StefanTT
Copy link

StefanTT commented Jul 12, 2020

You have to shift-rightclick an io port of the induction matrix.
Works for me without issues in 1.12.2

@robertm1771
Copy link

While shift-right click will show you the RF of the IO port max it doesn't show the induction matrix total power. One probe shows total induction matrix power max and current. But if you bind screen to a induction port you are limited by the induction matrix limit per your configuration of the matrix. While working am not sure it is working as you intend it to function.
image1
image2

@Nidaelie
Copy link

Nidaelie commented Dec 4, 2021

still an issue....

@McJty
Copy link
Collaborator

McJty commented Dec 4, 2021

And it will remain an issue. FE/RF is limited to 32-bit integer (2 billion). There is not much I can do about this