Is your feature request related to a problem? Please describe.

Following #99 discussions, we decided that it was relevant to add a turbopump component in WaterSteam.Machines.TurboPump, because it is a specific component, hard to model, with a complex causality, and handling power connectors caused issues.

Describe the solution you'd like
We could have a component with SteamInlet, SteamOutlet, FeedWaterInlet, FeedWaterOutlet, that way we can always add any sensor or component we want around, and it will give a causality hint too :)