Issue #1 : The enthalpy at GT exhaust is imposed as BC : parameter Units.SpecificEnthalpy GT_h_out=1e6;
parameter Units.SpecificEnthalpy GT_h_out=1e6;
However, the TET should be the CL. (since the mml3.0 upgrade, it should be a convergence problem anymore).
Issue #2 : The combustion chamber efficiency is imposed. parameter Real combustionChamber_eta = 0.9999;
parameter Real combustionChamber_eta = 0.9999;
However, it should be calibrated by the flue gases mass flow which is not associated to any parameter on the calibration_diagram.
Need to update the reverse model and calibration Diagram of MetroscopiaCCGT
The text was updated successfully, but these errors were encountered:
J'ai pas du tout compris pourquoi tu mentionnais ces PR @helenev-met mais je suis d'accord avec l'issue
Sorry, something went wrong.
No branches or pull requests
Issue #1 :
The enthalpy at GT exhaust is imposed as BC :
parameter Units.SpecificEnthalpy GT_h_out=1e6;
However, the TET should be the CL. (since the mml3.0 upgrade, it should be a convergence problem anymore).
Issue #2 :
The combustion chamber efficiency is imposed.
parameter Real combustionChamber_eta = 0.9999;
However, it should be calibrated by the flue gases mass flow which is not associated to any parameter on the calibration_diagram.
Need to update the reverse model and calibration Diagram of MetroscopiaCCGT