-
Notifications
You must be signed in to change notification settings - Fork 10
/
SyscallStreamingTraceSourceExtensions.xml
258 lines (258 loc) · 22.4 KB
/
SyscallStreamingTraceSourceExtensions.xml
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
<Type Name="SyscallStreamingTraceSourceExtensions" FullName="Microsoft.Windows.EventTracing.SyscallStreamingTraceSourceExtensions">
<TypeSignature Language="C#" Value="public static class SyscallStreamingTraceSourceExtensions" />
<TypeSignature Language="ILAsm" Value=".class public auto ansi abstract sealed beforefieldinit SyscallStreamingTraceSourceExtensions extends System.Object" />
<TypeSignature Language="DocId" Value="T:Microsoft.Windows.EventTracing.SyscallStreamingTraceSourceExtensions" />
<TypeSignature Language="VB.NET" Value="Public Module SyscallStreamingTraceSourceExtensions" />
<TypeSignature Language="F#" Value="type SyscallStreamingTraceSourceExtensions = class" />
<AssemblyInfo>
<AssemblyName>Microsoft.Windows.EventTracing.Syscalls</AssemblyName>
<AssemblyVersion>1.0.0.0</AssemblyVersion>
</AssemblyInfo>
<Base>
<BaseTypeName>System.Object</BaseTypeName>
</Base>
<Interfaces />
<Docs>
<summary>To be added.</summary>
<remarks>To be added.</remarks>
</Docs>
<Members>
<Member MemberName="UseSyscallEnterEvents">
<MemberSignature Language="C#" Value="public static void UseSyscallEnterEvents (this Microsoft.Windows.EventTracing.IStreamingTraceSource streamingTrace, Microsoft.Windows.EventTracing.Syscalls.ISyscallEnterEventConsumer consumer);" />
<MemberSignature Language="ILAsm" Value=".method public static hidebysig void UseSyscallEnterEvents(class Microsoft.Windows.EventTracing.IStreamingTraceSource streamingTrace, class Microsoft.Windows.EventTracing.Syscalls.ISyscallEnterEventConsumer consumer) cil managed" />
<MemberSignature Language="DocId" Value="M:Microsoft.Windows.EventTracing.SyscallStreamingTraceSourceExtensions.UseSyscallEnterEvents(Microsoft.Windows.EventTracing.IStreamingTraceSource,Microsoft.Windows.EventTracing.Syscalls.ISyscallEnterEventConsumer)" />
<MemberSignature Language="VB.NET" Value="<Extension()>
Public Sub UseSyscallEnterEvents (streamingTrace As IStreamingTraceSource, consumer As ISyscallEnterEventConsumer)" />
<MemberSignature Language="F#" Value="static member UseSyscallEnterEvents : Microsoft.Windows.EventTracing.IStreamingTraceSource * Microsoft.Windows.EventTracing.Syscalls.ISyscallEnterEventConsumer -> unit" Usage="Microsoft.Windows.EventTracing.SyscallStreamingTraceSourceExtensions.UseSyscallEnterEvents (streamingTrace, consumer)" />
<MemberType>Method</MemberType>
<AssemblyInfo>
<AssemblyName>Microsoft.Windows.EventTracing.Syscalls</AssemblyName>
<AssemblyVersion>1.0.0.0</AssemblyVersion>
</AssemblyInfo>
<ReturnValue>
<ReturnType>System.Void</ReturnType>
</ReturnValue>
<Parameters>
<Parameter Name="streamingTrace" Type="Microsoft.Windows.EventTracing.IStreamingTraceSource" RefType="this" />
<Parameter Name="consumer" Type="Microsoft.Windows.EventTracing.Syscalls.ISyscallEnterEventConsumer" />
</Parameters>
<Docs>
<param name="streamingTrace">The trace from which to access the data.</param>
<param name="consumer">The callback to call with the event parsing result.</param>
<summary>Registers a consumer to receive parsed syscall enter events when the trace is processed.</summary>
<remarks>
Event consumers that need to run in a specific pass can inherit from <see cref="T:Microsoft.Windows.EventTracing.IScheduledConsumer" />.
</remarks>
</Docs>
</Member>
<Member MemberName="UseSyscallEnterEvents">
<MemberSignature Language="C#" Value="public static void UseSyscallEnterEvents (this Microsoft.Windows.EventTracing.IStreamingTraceSource streamingTrace, Microsoft.Windows.EventTracing.Syscalls.SyscallEnterEventCallback process);" />
<MemberSignature Language="ILAsm" Value=".method public static hidebysig void UseSyscallEnterEvents(class Microsoft.Windows.EventTracing.IStreamingTraceSource streamingTrace, class Microsoft.Windows.EventTracing.Syscalls.SyscallEnterEventCallback process) cil managed" />
<MemberSignature Language="DocId" Value="M:Microsoft.Windows.EventTracing.SyscallStreamingTraceSourceExtensions.UseSyscallEnterEvents(Microsoft.Windows.EventTracing.IStreamingTraceSource,Microsoft.Windows.EventTracing.Syscalls.SyscallEnterEventCallback)" />
<MemberSignature Language="VB.NET" Value="<Extension()>
Public Sub UseSyscallEnterEvents (streamingTrace As IStreamingTraceSource, process As SyscallEnterEventCallback)" />
<MemberSignature Language="F#" Value="static member UseSyscallEnterEvents : Microsoft.Windows.EventTracing.IStreamingTraceSource * Microsoft.Windows.EventTracing.Syscalls.SyscallEnterEventCallback -> unit" Usage="Microsoft.Windows.EventTracing.SyscallStreamingTraceSourceExtensions.UseSyscallEnterEvents (streamingTrace, process)" />
<MemberType>Method</MemberType>
<AssemblyInfo>
<AssemblyName>Microsoft.Windows.EventTracing.Syscalls</AssemblyName>
<AssemblyVersion>1.0.0.0</AssemblyVersion>
</AssemblyInfo>
<ReturnValue>
<ReturnType>System.Void</ReturnType>
</ReturnValue>
<Parameters>
<Parameter Name="streamingTrace" Type="Microsoft.Windows.EventTracing.IStreamingTraceSource" RefType="this" />
<Parameter Name="process" Type="Microsoft.Windows.EventTracing.Syscalls.SyscallEnterEventCallback" />
</Parameters>
<Docs>
<param name="streamingTrace">The trace from which to access the data.</param>
<param name="process">The callback to register.</param>
<summary>Registers a callback to receive parsed syscall enter events when the trace is processed.</summary>
<remarks>To be added.</remarks>
</Docs>
</Member>
<Member MemberName="UseSyscallEnterEvents">
<MemberSignature Language="C#" Value="public static void UseSyscallEnterEvents (this Microsoft.Windows.EventTracing.IStreamingTraceSource streamingTrace, Microsoft.Windows.EventTracing.ConsumerSchedule schedule, Microsoft.Windows.EventTracing.Syscalls.SyscallEnterEventCallback process);" />
<MemberSignature Language="ILAsm" Value=".method public static hidebysig void UseSyscallEnterEvents(class Microsoft.Windows.EventTracing.IStreamingTraceSource streamingTrace, valuetype Microsoft.Windows.EventTracing.ConsumerSchedule schedule, class Microsoft.Windows.EventTracing.Syscalls.SyscallEnterEventCallback process) cil managed" />
<MemberSignature Language="DocId" Value="M:Microsoft.Windows.EventTracing.SyscallStreamingTraceSourceExtensions.UseSyscallEnterEvents(Microsoft.Windows.EventTracing.IStreamingTraceSource,Microsoft.Windows.EventTracing.ConsumerSchedule,Microsoft.Windows.EventTracing.Syscalls.SyscallEnterEventCallback)" />
<MemberSignature Language="VB.NET" Value="<Extension()>
Public Sub UseSyscallEnterEvents (streamingTrace As IStreamingTraceSource, schedule As ConsumerSchedule, process As SyscallEnterEventCallback)" />
<MemberSignature Language="F#" Value="static member UseSyscallEnterEvents : Microsoft.Windows.EventTracing.IStreamingTraceSource * Microsoft.Windows.EventTracing.ConsumerSchedule * Microsoft.Windows.EventTracing.Syscalls.SyscallEnterEventCallback -> unit" Usage="Microsoft.Windows.EventTracing.SyscallStreamingTraceSourceExtensions.UseSyscallEnterEvents (streamingTrace, schedule, process)" />
<MemberType>Method</MemberType>
<AssemblyInfo>
<AssemblyName>Microsoft.Windows.EventTracing.Syscalls</AssemblyName>
<AssemblyVersion>1.0.0.0</AssemblyVersion>
</AssemblyInfo>
<ReturnValue>
<ReturnType>System.Void</ReturnType>
</ReturnValue>
<Parameters>
<Parameter Name="streamingTrace" Type="Microsoft.Windows.EventTracing.IStreamingTraceSource" RefType="this" />
<Parameter Name="schedule" Type="Microsoft.Windows.EventTracing.ConsumerSchedule" />
<Parameter Name="process" Type="Microsoft.Windows.EventTracing.Syscalls.SyscallEnterEventCallback" />
</Parameters>
<Docs>
<param name="streamingTrace">The trace from which to access the data.</param>
<param name="schedule">The schedule indicating when to parse the events.</param>
<param name="process">The callback to register.</param>
<summary>Registers a callback to receive parsed syscall enter events when the trace is processed.</summary>
<remarks>To be added.</remarks>
</Docs>
</Member>
<Member MemberName="UseSyscallExitEvents">
<MemberSignature Language="C#" Value="public static void UseSyscallExitEvents (this Microsoft.Windows.EventTracing.IStreamingTraceSource streamingTrace, Microsoft.Windows.EventTracing.Syscalls.ISyscallExitEventConsumer consumer);" />
<MemberSignature Language="ILAsm" Value=".method public static hidebysig void UseSyscallExitEvents(class Microsoft.Windows.EventTracing.IStreamingTraceSource streamingTrace, class Microsoft.Windows.EventTracing.Syscalls.ISyscallExitEventConsumer consumer) cil managed" />
<MemberSignature Language="DocId" Value="M:Microsoft.Windows.EventTracing.SyscallStreamingTraceSourceExtensions.UseSyscallExitEvents(Microsoft.Windows.EventTracing.IStreamingTraceSource,Microsoft.Windows.EventTracing.Syscalls.ISyscallExitEventConsumer)" />
<MemberSignature Language="VB.NET" Value="<Extension()>
Public Sub UseSyscallExitEvents (streamingTrace As IStreamingTraceSource, consumer As ISyscallExitEventConsumer)" />
<MemberSignature Language="F#" Value="static member UseSyscallExitEvents : Microsoft.Windows.EventTracing.IStreamingTraceSource * Microsoft.Windows.EventTracing.Syscalls.ISyscallExitEventConsumer -> unit" Usage="Microsoft.Windows.EventTracing.SyscallStreamingTraceSourceExtensions.UseSyscallExitEvents (streamingTrace, consumer)" />
<MemberType>Method</MemberType>
<AssemblyInfo>
<AssemblyName>Microsoft.Windows.EventTracing.Syscalls</AssemblyName>
<AssemblyVersion>1.0.0.0</AssemblyVersion>
</AssemblyInfo>
<ReturnValue>
<ReturnType>System.Void</ReturnType>
</ReturnValue>
<Parameters>
<Parameter Name="streamingTrace" Type="Microsoft.Windows.EventTracing.IStreamingTraceSource" RefType="this" />
<Parameter Name="consumer" Type="Microsoft.Windows.EventTracing.Syscalls.ISyscallExitEventConsumer" />
</Parameters>
<Docs>
<param name="streamingTrace">The trace from which to access the data.</param>
<param name="consumer">The callback to call with the event parsing result.</param>
<summary>Registers a consumer to receive parsed syscall exit events when the trace is processed.</summary>
<remarks>
Event consumers that need to run in a specific pass can inherit from <see cref="T:Microsoft.Windows.EventTracing.IScheduledConsumer" />.
</remarks>
</Docs>
</Member>
<Member MemberName="UseSyscallExitEvents">
<MemberSignature Language="C#" Value="public static void UseSyscallExitEvents (this Microsoft.Windows.EventTracing.IStreamingTraceSource streamingTrace, Microsoft.Windows.EventTracing.Syscalls.SyscallExitEventCallback process);" />
<MemberSignature Language="ILAsm" Value=".method public static hidebysig void UseSyscallExitEvents(class Microsoft.Windows.EventTracing.IStreamingTraceSource streamingTrace, class Microsoft.Windows.EventTracing.Syscalls.SyscallExitEventCallback process) cil managed" />
<MemberSignature Language="DocId" Value="M:Microsoft.Windows.EventTracing.SyscallStreamingTraceSourceExtensions.UseSyscallExitEvents(Microsoft.Windows.EventTracing.IStreamingTraceSource,Microsoft.Windows.EventTracing.Syscalls.SyscallExitEventCallback)" />
<MemberSignature Language="VB.NET" Value="<Extension()>
Public Sub UseSyscallExitEvents (streamingTrace As IStreamingTraceSource, process As SyscallExitEventCallback)" />
<MemberSignature Language="F#" Value="static member UseSyscallExitEvents : Microsoft.Windows.EventTracing.IStreamingTraceSource * Microsoft.Windows.EventTracing.Syscalls.SyscallExitEventCallback -> unit" Usage="Microsoft.Windows.EventTracing.SyscallStreamingTraceSourceExtensions.UseSyscallExitEvents (streamingTrace, process)" />
<MemberType>Method</MemberType>
<AssemblyInfo>
<AssemblyName>Microsoft.Windows.EventTracing.Syscalls</AssemblyName>
<AssemblyVersion>1.0.0.0</AssemblyVersion>
</AssemblyInfo>
<ReturnValue>
<ReturnType>System.Void</ReturnType>
</ReturnValue>
<Parameters>
<Parameter Name="streamingTrace" Type="Microsoft.Windows.EventTracing.IStreamingTraceSource" RefType="this" />
<Parameter Name="process" Type="Microsoft.Windows.EventTracing.Syscalls.SyscallExitEventCallback" />
</Parameters>
<Docs>
<param name="streamingTrace">The trace from which to access the data.</param>
<param name="process">The callback to register.</param>
<summary>Registers a callback to receive parsed syscall exit events when the trace is processed.</summary>
<remarks>To be added.</remarks>
</Docs>
</Member>
<Member MemberName="UseSyscallExitEvents">
<MemberSignature Language="C#" Value="public static void UseSyscallExitEvents (this Microsoft.Windows.EventTracing.IStreamingTraceSource streamingTrace, Microsoft.Windows.EventTracing.ConsumerSchedule schedule, Microsoft.Windows.EventTracing.Syscalls.SyscallExitEventCallback process);" />
<MemberSignature Language="ILAsm" Value=".method public static hidebysig void UseSyscallExitEvents(class Microsoft.Windows.EventTracing.IStreamingTraceSource streamingTrace, valuetype Microsoft.Windows.EventTracing.ConsumerSchedule schedule, class Microsoft.Windows.EventTracing.Syscalls.SyscallExitEventCallback process) cil managed" />
<MemberSignature Language="DocId" Value="M:Microsoft.Windows.EventTracing.SyscallStreamingTraceSourceExtensions.UseSyscallExitEvents(Microsoft.Windows.EventTracing.IStreamingTraceSource,Microsoft.Windows.EventTracing.ConsumerSchedule,Microsoft.Windows.EventTracing.Syscalls.SyscallExitEventCallback)" />
<MemberSignature Language="VB.NET" Value="<Extension()>
Public Sub UseSyscallExitEvents (streamingTrace As IStreamingTraceSource, schedule As ConsumerSchedule, process As SyscallExitEventCallback)" />
<MemberSignature Language="F#" Value="static member UseSyscallExitEvents : Microsoft.Windows.EventTracing.IStreamingTraceSource * Microsoft.Windows.EventTracing.ConsumerSchedule * Microsoft.Windows.EventTracing.Syscalls.SyscallExitEventCallback -> unit" Usage="Microsoft.Windows.EventTracing.SyscallStreamingTraceSourceExtensions.UseSyscallExitEvents (streamingTrace, schedule, process)" />
<MemberType>Method</MemberType>
<AssemblyInfo>
<AssemblyName>Microsoft.Windows.EventTracing.Syscalls</AssemblyName>
<AssemblyVersion>1.0.0.0</AssemblyVersion>
</AssemblyInfo>
<ReturnValue>
<ReturnType>System.Void</ReturnType>
</ReturnValue>
<Parameters>
<Parameter Name="streamingTrace" Type="Microsoft.Windows.EventTracing.IStreamingTraceSource" RefType="this" />
<Parameter Name="schedule" Type="Microsoft.Windows.EventTracing.ConsumerSchedule" />
<Parameter Name="process" Type="Microsoft.Windows.EventTracing.Syscalls.SyscallExitEventCallback" />
</Parameters>
<Docs>
<param name="streamingTrace">The trace from which to access the data.</param>
<param name="schedule">The schedule indicating when to parse the events.</param>
<param name="process">The callback to register.</param>
<summary>Registers a callback to receive parsed syscall exit events when the trace is processed.</summary>
<remarks>To be added.</remarks>
</Docs>
</Member>
<Member MemberName="UseSyscalls">
<MemberSignature Language="C#" Value="public static void UseSyscalls (this Microsoft.Windows.EventTracing.IStreamingTraceSource streamingTrace, Microsoft.Windows.EventTracing.Syscalls.ISyscallConsumer consumer);" />
<MemberSignature Language="ILAsm" Value=".method public static hidebysig void UseSyscalls(class Microsoft.Windows.EventTracing.IStreamingTraceSource streamingTrace, class Microsoft.Windows.EventTracing.Syscalls.ISyscallConsumer consumer) cil managed" />
<MemberSignature Language="DocId" Value="M:Microsoft.Windows.EventTracing.SyscallStreamingTraceSourceExtensions.UseSyscalls(Microsoft.Windows.EventTracing.IStreamingTraceSource,Microsoft.Windows.EventTracing.Syscalls.ISyscallConsumer)" />
<MemberSignature Language="VB.NET" Value="<Extension()>
Public Sub UseSyscalls (streamingTrace As IStreamingTraceSource, consumer As ISyscallConsumer)" />
<MemberSignature Language="F#" Value="static member UseSyscalls : Microsoft.Windows.EventTracing.IStreamingTraceSource * Microsoft.Windows.EventTracing.Syscalls.ISyscallConsumer -> unit" Usage="Microsoft.Windows.EventTracing.SyscallStreamingTraceSourceExtensions.UseSyscalls (streamingTrace, consumer)" />
<MemberType>Method</MemberType>
<AssemblyInfo>
<AssemblyName>Microsoft.Windows.EventTracing.Syscalls</AssemblyName>
<AssemblyVersion>1.0.0.0</AssemblyVersion>
</AssemblyInfo>
<ReturnValue>
<ReturnType>System.Void</ReturnType>
</ReturnValue>
<Parameters>
<Parameter Name="streamingTrace" Type="Microsoft.Windows.EventTracing.IStreamingTraceSource" RefType="this" />
<Parameter Name="consumer" Type="Microsoft.Windows.EventTracing.Syscalls.ISyscallConsumer" />
</Parameters>
<Docs>
<param name="streamingTrace">The trace from which to access the data.</param>
<param name="consumer">The callback to call with the result.</param>
<summary>Registers a consumer to receive system call data when the trace is processed.</summary>
<remarks>
Event consumers that need to run in a specific pass can inherit from <see cref="T:Microsoft.Windows.EventTracing.IScheduledConsumer" />.
</remarks>
</Docs>
</Member>
<Member MemberName="UseSyscalls">
<MemberSignature Language="C#" Value="public static void UseSyscalls (this Microsoft.Windows.EventTracing.IStreamingTraceSource streamingTrace, Microsoft.Windows.EventTracing.Syscalls.SyscallCallback process);" />
<MemberSignature Language="ILAsm" Value=".method public static hidebysig void UseSyscalls(class Microsoft.Windows.EventTracing.IStreamingTraceSource streamingTrace, class Microsoft.Windows.EventTracing.Syscalls.SyscallCallback process) cil managed" />
<MemberSignature Language="DocId" Value="M:Microsoft.Windows.EventTracing.SyscallStreamingTraceSourceExtensions.UseSyscalls(Microsoft.Windows.EventTracing.IStreamingTraceSource,Microsoft.Windows.EventTracing.Syscalls.SyscallCallback)" />
<MemberSignature Language="VB.NET" Value="<Extension()>
Public Sub UseSyscalls (streamingTrace As IStreamingTraceSource, process As SyscallCallback)" />
<MemberSignature Language="F#" Value="static member UseSyscalls : Microsoft.Windows.EventTracing.IStreamingTraceSource * Microsoft.Windows.EventTracing.Syscalls.SyscallCallback -> unit" Usage="Microsoft.Windows.EventTracing.SyscallStreamingTraceSourceExtensions.UseSyscalls (streamingTrace, process)" />
<MemberType>Method</MemberType>
<AssemblyInfo>
<AssemblyName>Microsoft.Windows.EventTracing.Syscalls</AssemblyName>
<AssemblyVersion>1.0.0.0</AssemblyVersion>
</AssemblyInfo>
<ReturnValue>
<ReturnType>System.Void</ReturnType>
</ReturnValue>
<Parameters>
<Parameter Name="streamingTrace" Type="Microsoft.Windows.EventTracing.IStreamingTraceSource" RefType="this" />
<Parameter Name="process" Type="Microsoft.Windows.EventTracing.Syscalls.SyscallCallback" />
</Parameters>
<Docs>
<param name="streamingTrace">The trace from which to access the data.</param>
<param name="process">The callback to register.</param>
<summary>Registers a callback to receive system call data when the trace is processed.</summary>
<remarks>To be added.</remarks>
</Docs>
</Member>
<Member MemberName="UseSyscalls">
<MemberSignature Language="C#" Value="public static void UseSyscalls (this Microsoft.Windows.EventTracing.IStreamingTraceSource streamingTrace, Microsoft.Windows.EventTracing.ConsumerSchedule schedule, Microsoft.Windows.EventTracing.Syscalls.SyscallCallback process);" />
<MemberSignature Language="ILAsm" Value=".method public static hidebysig void UseSyscalls(class Microsoft.Windows.EventTracing.IStreamingTraceSource streamingTrace, valuetype Microsoft.Windows.EventTracing.ConsumerSchedule schedule, class Microsoft.Windows.EventTracing.Syscalls.SyscallCallback process) cil managed" />
<MemberSignature Language="DocId" Value="M:Microsoft.Windows.EventTracing.SyscallStreamingTraceSourceExtensions.UseSyscalls(Microsoft.Windows.EventTracing.IStreamingTraceSource,Microsoft.Windows.EventTracing.ConsumerSchedule,Microsoft.Windows.EventTracing.Syscalls.SyscallCallback)" />
<MemberSignature Language="VB.NET" Value="<Extension()>
Public Sub UseSyscalls (streamingTrace As IStreamingTraceSource, schedule As ConsumerSchedule, process As SyscallCallback)" />
<MemberSignature Language="F#" Value="static member UseSyscalls : Microsoft.Windows.EventTracing.IStreamingTraceSource * Microsoft.Windows.EventTracing.ConsumerSchedule * Microsoft.Windows.EventTracing.Syscalls.SyscallCallback -> unit" Usage="Microsoft.Windows.EventTracing.SyscallStreamingTraceSourceExtensions.UseSyscalls (streamingTrace, schedule, process)" />
<MemberType>Method</MemberType>
<AssemblyInfo>
<AssemblyName>Microsoft.Windows.EventTracing.Syscalls</AssemblyName>
<AssemblyVersion>1.0.0.0</AssemblyVersion>
</AssemblyInfo>
<ReturnValue>
<ReturnType>System.Void</ReturnType>
</ReturnValue>
<Parameters>
<Parameter Name="streamingTrace" Type="Microsoft.Windows.EventTracing.IStreamingTraceSource" RefType="this" />
<Parameter Name="schedule" Type="Microsoft.Windows.EventTracing.ConsumerSchedule" />
<Parameter Name="process" Type="Microsoft.Windows.EventTracing.Syscalls.SyscallCallback" />
</Parameters>
<Docs>
<param name="streamingTrace">The trace from which to access the data.</param>
<param name="schedule">The schedule indicating when to parse the events.</param>
<param name="process">The callback to register.</param>
<summary>Registers a callback to receive system call data when the trace is processed.</summary>
<remarks>To be added.</remarks>
</Docs>
</Member>
</Members>
</Type>