Get-NetQosFlowControl |
Gets the priority-based flow control (PFC) settings.
Get-NetQosFlowControl [[-Priority] <Byte[]>] [-CimSession <CimSession[]>] [-ThrottleLimit <Int32>] [-AsJob]
[<CommonParameters>]
The Get-NetQosFlowControl cmdlet gets the priority-based flow control (PFC) settings programmed in Windows Server® 2012 and later.
For more information on PFC, see the Enable-NetQosFlowControl cmdlet.
PFC is part of the IEEE data center bridging (DCB) standard.
PS C:\> Get-NetQosFlowControl
Priority Enabled
-------- -------
0 False
1 False
2 False
3 True
4 False
5 False
6 False
7 False
This example displays flow control settings.
ps_cimcommon_asjob
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
Runs the cmdlet in a remote session or on a remote computer. Enter a computer name or a session object, such as the output of a New-CimSessionhttp://go.microsoft.com/fwlink/p/?LinkId=227967 or Get-CimSessionhttp://go.microsoft.com/fwlink/p/?LinkId=227966 cmdlet. The default is the current session on the local computer.
Type: CimSession[]
Parameter Sets: (All)
Aliases: Session
Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
Specifies the IEEE 802.1p priority value.
Type: Byte[]
Parameter Sets: (All)
Aliases:
Required: False
Position: 0
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
Specifies the maximum number of concurrent operations that can be established to run the cmdlet.
If this parameter is omitted or a value of 0
is entered, then Windows PowerShell® calculates an optimum throttle limit for the cmdlet based on the number of CIM cmdlets that are running on the computer.
The throttle limit applies only to the current cmdlet, not to the session or to the computer.
Type: Int32
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
This cmdlet supports the common parameters: -Debug, -ErrorAction, -ErrorVariable, -InformationAction, -InformationVariable, -OutVariable, -OutBuffer, -PipelineVariable, -Verbose, -WarningAction, and -WarningVariable. For more information, see about_CommonParameters (http://go.microsoft.com/fwlink/?LinkID=113216).
Microsoft.Management.Infrastructure.CimInstance#ROOT/StandardCimv2/MSFT_NetQosFlowControlSettingData
The Microsoft.Management.Infrastructure.CimInstance
object is a wrapper class that displays Windows Management Instrumentation (WMI) objects.
The path after the pound sign (#
) provides the namespace and class name for the underlying WMI object.
The MSFT_NetQosFlowControlSettingData object contains the flow control settings per priority.