description | external help file | Module Name | ms.date | online version | schema | title |
---|---|---|---|---|---|---|
Use this topic to help manage Windows and Windows Server technologies with Windows PowerShell. |
MSFT_EtwTraceProvider_v1.0.cdxml-help.xml |
EventTracingManagement |
01/05/2017 |
2.0.0 |
Remove-EtwTraceProvider |
Removes an ETW provider from the ETW or AutoLogger session.
Remove-EtwTraceProvider [[-Guid] <String[]>] [-AutologgerName <String[]>] [-CimSession <CimSession[]>]
[-ThrottleLimit <Int32>] [-AsJob] [-PassThru] [-WhatIf] [-Confirm] [<CommonParameters>]
Remove-EtwTraceProvider [[-Guid] <String[]>] [-SessionName <String[]>] [-CimSession <CimSession[]>]
[-ThrottleLimit <Int32>] [-AsJob] [-PassThru] [-WhatIf] [-Confirm] [<CommonParameters>]
Remove-EtwTraceProvider -InputObject <CimInstance[]> [-CimSession <CimSession[]>] [-ThrottleLimit <Int32>]
[-AsJob] [-PassThru] [-WhatIf] [-Confirm] [<CommonParameters>]
The Remove-EtwTraceProvider cmdlet removes an ETW provider from the ETW or AutoLogger session.
PS C:\> Remove-EtwTraceProvider -Guid "{9C88041D-349D-4647-8BFD-2C0A167BFE58}" -SessionName "TestSession17"
SessionName : TestSession
AutologgerName :
Guid : {5EEFEBDB-E90C-423A-8ABF-0241E7C5B87D }
Level : 2
MatchAnyKeyword : 0xFFFFFFFF
MatchAllKeyword : 0x00000000
Property :
This command removes the ETW Trace Provider that has the specified GUID from the session named TestSession17.
Runs the cmdlet as a background job. Use this parameter to run commands that take a long time to complete.
The cmdlet immediately returns an object that represents the job and then displays the command prompt.
You can continue to work in the session while the job completes.
To manage the job, use the *-Job
cmdlets.
To get the job results, use the Receive-Job cmdlet.
For more information about Windows PowerShell background jobs, see about_Jobs.
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
Specifies the name of the target AutoLogger session.
Type: String[]
Parameter Sets: ByAutologger
Aliases:
Required: False
Position: Named
Default value: None
Accept pipeline input: True (ByPropertyName)
Accept wildcard characters: False
Runs the cmdlet in a remote session or on a remote computer. Enter a computer name or a session object, such as the output of a New-CimSession or Get-CimSession cmdlet. The default is the current session on the local computer.
Type: CimSession[]
Parameter Sets: (All)
Aliases: Session
Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
Prompts you for confirmation before running the cmdlet.
Type: SwitchParameter
Parameter Sets: (All)
Aliases: cf
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
Specifies the provider ID.
Type: String[]
Parameter Sets: ByAutologger, BySession
Aliases:
Required: False
Position: 0
Default value: None
Accept pipeline input: True (ByPropertyName)
Accept wildcard characters: False
Specifies the input to this cmdlet. You can use this parameter, or you can pipe the input to this cmdlet.
Type: CimInstance[]
Parameter Sets: InputObject (cdxml)
Aliases:
Required: True
Position: Named
Default value: None
Accept pipeline input: True (ByValue)
Accept wildcard characters: False
Indicates that this cmdlet returns an object that represents the item on which it operates. By default, this cmdlet does not generate any output.
Type: SwitchParameter
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
Specifies the name of the target ETW session.
Type: String[]
Parameter Sets: BySession
Aliases:
Required: False
Position: Named
Default value: None
Accept pipeline input: True (ByPropertyName)
Accept wildcard characters: False
Specifies the maximum number of concurrent operations that can be established to run the cmdlet.
If this parameter is omitted or a value of 0
is entered, then Windows PowerShell® calculates an optimum throttle limit for the cmdlet based on the number of CIM cmdlets that are running on the computer.
The throttle limit applies only to the current cmdlet, not to the session or to the computer.
Type: Int32
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
Shows what would happen if the cmdlet runs. The cmdlet is not run.
Type: SwitchParameter
Parameter Sets: (All)
Aliases: wi
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
This cmdlet supports the common parameters: -Debug, -ErrorAction, -ErrorVariable, -InformationAction, -InformationVariable, -OutVariable, -OutBuffer, -PipelineVariable, -Verbose, -WarningAction, and -WarningVariable. For more information, see about_CommonParameters.
Configuring and Starting an AutoLogger Session