You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
We have a thousands of units thats been configured to have an hourly measurement.
But the sensors keeps sending blank payloads 2 times every hour, and the measurement once an hour.
Measurements are sent on Port 85 as described in documentation.
However the blank payloads are sent on application port 0 and is nowhere to be found in documentation.
We are considered that this will cost battery lifetime.
Why is the sensor sending these empty payloads?
Will it cost battery lifetime?
If so, How is that turned off?
We do not see this type of behavior on other provider of sensors or in EM500.
The text was updated successfully, but these errors were encountered:
Blank/empty payloads on port 0 are used by the LoRaWAN protocol itself to send MAC commands in the frame header, such as LinkCheckRequest . I suggest examining the frame header of these uplinks to see what they contain.
I recall that MileSight IoT uses LinkCheckRequest to validate LNS availability when Re-Join mode is enabled. See section 3.2 of the EM-300 user guide:
We have a thousands of units thats been configured to have an hourly measurement.
But the sensors keeps sending blank payloads 2 times every hour, and the measurement once an hour.
Measurements are sent on Port 85 as described in documentation.
However the blank payloads are sent on application port 0 and is nowhere to be found in documentation.
We are considered that this will cost battery lifetime.
We do not see this type of behavior on other provider of sensors or in EM500.
The text was updated successfully, but these errors were encountered: