When you configure multiple APU's on a single FPGA, the analog replay's on APU's other than the first one may not work. However if you configure all of the Analog Replay's onto the main APU page, then everything works correctly. This works because the APU's are linked to their specific modules on the FPGA, so even if analog replay "4" is configured on the page for APU "1", it is still wired to the register bus for APU "4" so it will look up it's current position using the proper APU.
The text was updated successfully, but these errors were encountered:
When you configure multiple APU's on a single FPGA, the analog replay's on APU's other than the first one may not work. However if you configure all of the Analog Replay's onto the main APU page, then everything works correctly. This works because the APU's are linked to their specific modules on the FPGA, so even if analog replay "4" is configured on the page for APU "1", it is still wired to the register bus for APU "4" so it will look up it's current position using the proper APU.