Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Insufficient Calibrations Found; arc darks #10

Open
Nat1405 opened this issue May 22, 2020 · 0 comments
Open

Insufficient Calibrations Found; arc darks #10

Nat1405 opened this issue May 22, 2020 · 0 comments

Comments

@Nat1405
Copy link
Owner

Nat1405 commented May 22, 2020

This bug was found when trying to reduce GN-2006B-Q-107. Arc darks for 20060102 don't exist for that particular program (or any program), but they do exist for a different program on the day before and the day after. Nifty should probably be able to look for missing calibrations in all nifs programs one day before and after the observation in question. After that it should error out and let a user try to find appropriate calibrations.
Essentially, the pipeline should:

  • Query a data source for $calibration_types, matching $observation_day, $type=dayCal where $observation_day is the original observation date +- 1 day, and
  • Download this data into the appropriate rawData directory
  • .... Restart the sort? Hopefully sort is fully idempotent.