Verify status bits are correct for the one channel power supply #7

Closed
Nicoretti opened this issue Jul 21, 2020 · 2 comments
Closed
Labels
bug Something isn't working

Comments

@Nicoretti
Copy link
Owner

Verifiy that all flags are match the ones documented in the ka3005p documentation

@Nicoretti Nicoretti added the bug Something isn't working label Jul 21, 2020
@JackNewman12
Copy link
Contributor

They seem perfect to me on all the devices I have used. (multiple brands too).

However I see that some other online libraries seem to use some undocumented (as far as I can tell) bitfields in the status command to see if OCP or OVP is enabled. Might we worth a look at this.

@Nicoretti
Copy link
Owner Author

Hi Jack,

sounds reasonable, I will close this ticket and I also created a ticket where we can track the investigation of the undocumented status bitflags you mentioned.

best
Nico