-
Notifications
You must be signed in to change notification settings - Fork 298
/
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump1.mos
95 lines (90 loc) · 11.8 KB
/
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump1.mos
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
// name: ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump1
// keywords: simulation commonSubExp
// status: correct
//
loadModel(Modelica, {"3.2.1"}); getErrorString();
loadModel(ThermoSysPro); getErrorString();
simulate(ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump1, stopTime=1000); getErrorString();
system("xz --keep --decompress --force ./ReferenceFiles/ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump1.mat.xz");
(success, failVars) := OpenModelica.Scripting.diffSimulationResults(
"ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump1_res.mat",
"ReferenceFiles/ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump1.mat",
"ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump1_diff.csv",
vars={"centrifugalPump.w"}); getErrorString();
if success then
print("Files equal!\n");
else
print("Files not equal!\n");
for v in failVars loop
curFile := "ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump1." + v + ".html";
success := writeFile(curFile, OpenModelica.Scripting.diffSimulationResultsHtml(v, "ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump1_res.mat", "./ReferenceFiles/ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump1.mat", 0.01)); getErrorString();
if success then
print("Created diff file " + curFile + "\n");
else
print("Creating diff file " + curFile + " failed\n");
end if;
end for; getErrorString();
end if;
system("rm -f ./ReferenceFiles/ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump1.mat");
// Result:
// true
// ""
// true
// "Warning: Requested package Modelica of version 3.2.3, but this package was already loaded with version 3.2.1. There are no conversion annotations for this version but 3.2.3 is newer than 3.2.1. There is a possibility that 3.2.1 remains backwards compatible, but it is not loaded so OpenModelica cannot verify this.
// "
// record SimulationResult
// resultFile = "ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump1_res.mat",
// simulationOptions = "startTime = 0.0, stopTime = 1000.0, numberOfIntervals = 500, tolerance = 1e-06, method = 'dassl', fileNamePrefix = 'ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump1', options = '', outputFormat = 'mat', variableFilter = '.*', cflags = '', simflags = ''",
// messages = "LOG_SUCCESS | info | The initialization finished successfully without homotopy method.
// LOG_SUCCESS | info | The simulation finished successfully.
// "
// end SimulationResult;
// "Warning: Requested package Modelica of version 3.2.3, but this package was already loaded with version 3.2.1. You might experience problems if these versions are incompatible.
// [ThermoSysPro 3.2.0/WaterSteam/Connectors.mo:3:3-43:17:writable] Warning: Connector .ThermoSysPro.WaterSteam.Connectors.FluidInlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
// [ThermoSysPro 3.2.0/WaterSteam/Connectors.mo:87:3-127:18:writable] Warning: Connector .ThermoSysPro.WaterSteam.Connectors.FluidOutlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
// [ThermoSysPro 3.2.0/ElectroMechanics/Connectors.mo:3:3-36:24:writable] Warning: Connector .ThermoSysPro.ElectroMechanics.Connectors.MechanichalTorque is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0).
// [ThermoSysPro 3.2.0/Properties/WaterSteam/Common.mo:1494:3-1528:30:writable] Warning: sat.T was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
// [ThermoSysPro 3.2.0/Properties/WaterSteam/Common.mo:1494:3-1528:30:writable] Warning: sat.dpT was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
// [ThermoSysPro 3.2.0/Properties/WaterSteam/Common.mo:1552:3-1581:34:writable] Warning: sat.T was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
// [ThermoSysPro 3.2.0/Properties/WaterSteam/Common.mo:1552:3-1581:34:writable] Warning: sat.dpT was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
// [ThermoSysPro 3.2.0/Properties/WaterSteam/Common.mo:1552:3-1581:34:writable] Warning: sat.cpt was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
// [ThermoSysPro 3.2.0/Properties/WaterSteam/Common.mo:1552:3-1581:34:writable] Warning: sat.vt was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
// [ThermoSysPro 3.2.0/Properties/WaterSteam/Common.mo:1552:3-1581:34:writable] Warning: sat.vp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
// [ThermoSysPro 3.2.0/Properties/WaterSteam/Common.mo:1552:3-1581:34:writable] Warning: sat.vtt was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
// [ThermoSysPro 3.2.0/Properties/WaterSteam/Common.mo:1552:3-1581:34:writable] Warning: sat.vpp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
// [ThermoSysPro 3.2.0/Properties/WaterSteam/Common.mo:1552:3-1581:34:writable] Warning: sat.vtp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
// [ThermoSysPro 3.2.0/Properties/WaterSteam/IF97_packages.mo:1089:9-1089:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
// [ThermoSysPro 3.2.0/Properties/WaterSteam/IF97_packages.mo:851:9-851:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
// [ThermoSysPro 3.2.0/Properties/WaterSteam/IF97_packages.mo:784:9-784:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
// [ThermoSysPro 3.2.0/Properties/WaterSteam/Common.mo:162:3-214:22:writable] Warning: pro.x was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
// [ThermoSysPro 3.2.0/Properties/WaterSteam/Common.mo:252:3-295:26:writable] Warning: pro.duph was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
// [ThermoSysPro 3.2.0/Properties/WaterSteam/Common.mo:252:3-295:26:writable] Warning: pro.duhp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
// [ThermoSysPro 3.2.0/Properties/WaterSteam/Common.mo:252:3-295:26:writable] Warning: pro.x was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
// [ThermoSysPro 3.2.0/Properties/WaterSteam/Common.mo:1270:3-1340:18:writable] Warning: pro.duph was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
// [ThermoSysPro 3.2.0/Properties/WaterSteam/Common.mo:1270:3-1340:18:writable] Warning: pro.duhp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
// [ThermoSysPro 3.2.0/Properties/C3H3F5/C3H3F5_Ph.mo:2:1-131:14:writable] Warning: pro.u was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
// [ThermoSysPro 3.2.0/Properties/C3H3F5/C3H3F5_Ph.mo:2:1-131:14:writable] Warning: pro.cp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
// [ThermoSysPro 3.2.0/Properties/C3H3F5/C3H3F5_Ph.mo:2:1-131:14:writable] Warning: pro.ddhp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
// [ThermoSysPro 3.2.0/Properties/C3H3F5/C3H3F5_Ph.mo:2:1-131:14:writable] Warning: pro.ddph was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
// [ThermoSysPro 3.2.0/Properties/C3H3F5/C3H3F5_Ph.mo:2:1-131:14:writable] Warning: pro.duph was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
// [ThermoSysPro 3.2.0/Properties/C3H3F5/C3H3F5_Ph.mo:2:1-131:14:writable] Warning: pro.duhp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
// [ThermoSysPro 3.2.0/Properties/WaterSteamSimple/prop4_Ph_der.mo:179:3-182:49:writable] Warning: du1satp_der was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
// [ThermoSysPro 3.2.0/Properties/WaterSteamSimple/prop4_Ph_der.mo:179:3-182:49:writable] Warning: du2satp_der was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
// [ThermoSysPro 3.2.0/Properties/WaterSteamSimple/prop4_Ph.mo:76:3-76:60:writable] Warning: dh1satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
// [ThermoSysPro 3.2.0/Properties/WaterSteamSimple/prop4_Ph.mo:76:3-76:60:writable] Warning: dh2satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed.
// [ThermoSysPro 3.2.0/WaterSteam/Connectors.mo:87:3-127:18:writable] Warning: Connector .ThermoSysPro.WaterSteam.Connectors.FluidOutlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
// [ThermoSysPro 3.2.0/WaterSteam/Connectors.mo:3:3-43:17:writable] Warning: Connector .ThermoSysPro.WaterSteam.Connectors.FluidInlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
// [ThermoSysPro 3.2.0/ElectroMechanics/Connectors.mo:3:3-36:24:writable] Warning: Connector .ThermoSysPro.ElectroMechanics.Connectors.MechanichalTorque is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0).
// [ThermoSysPro 3.2.0/WaterSteam/Connectors.mo:87:3-127:18:writable] Warning: Connector .ThermoSysPro.WaterSteam.Connectors.FluidOutlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
// [ThermoSysPro 3.2.0/WaterSteam/Connectors.mo:3:3-43:17:writable] Warning: Connector .ThermoSysPro.WaterSteam.Connectors.FluidInlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
// [ThermoSysPro 3.2.0/WaterSteam/Connectors.mo:87:3-127:18:writable] Warning: Connector .ThermoSysPro.WaterSteam.Connectors.FluidOutlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
// [ThermoSysPro 3.2.0/ElectroMechanics/Connectors.mo:3:3-36:24:writable] Warning: Connector .ThermoSysPro.ElectroMechanics.Connectors.MechanichalTorque is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0).
// [ThermoSysPro 3.2.0/WaterSteam/Connectors.mo:3:3-43:17:writable] Warning: Connector .ThermoSysPro.WaterSteam.Connectors.FluidInlet is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0).
// "
// 0
//
// ""
// Files equal!
//
// 0
// endResult