zv9040.xml
147 lines (146 loc) · 7.38 KB
/
zv9040.xml
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
<?xml version="1.0" encoding="utf-8"?>
<Product xmlns='http://code.google.com/p/open-zwave/'>
<!--
Tronika ZV9040
Manual: https://www.robbshop.nl/amfilerating/file/download/file_id/833/
-->
<!-- Configuration -->
<CommandClass id="112">
<Value type="list" genre="config" instance="1" index="2" label="Saving state before power failure" size="1" value="1">
<Help>
Saving state before power failure.
Default Not saved.
</Help>
<Item label="State NOT saved at power failure, all outputs are set to OFF upon power restore" value="0"/>
<Item label="State NOT saved at power failure, all outputs are set to ON upon power restore" value="1"/>
<Item label="State saved at power failure, all outputs are set to previous state upon power restore" value="2"/>
</Value>
<Value type="list" genre="config" instance="1" index="3" label="Send the basic report" size="1" value="1">
<Help>Enable/disable to send the basic report to the Lifeline when the load state changed.
When value set as 1, re-power on the dimmer, it will send Basic report automatically.
Default Enabled.
</Help>
<Item label="Disable" value="0"/>
<Item label="Enable" value="1"/>
</Value>
<Value type="byte" genre="config" instance="1" index="4" label="Fade time" min="0" max="255" value="1">
<Help>Fade time (units between 1-127 represent 1-127 seconds.
Units Betwen 128-244 represent minutes, 128 = 1 minute, 129 = 2 minutes.
This value has the same function as Duration of Multilevel).
Default 1.
</Help>
</Value>
<Value type="byte" genre="config" instance="1" index="5" label="Setting minimum brightness value" min="0" max="50" value="0">
<Help>Setting minimum brightness value.
Valid value: 0 - 50, the bigger the value is, the higher the loads minimum brightness is.
Note: when configure this value, the value of Multilevel will be configured as 1 automatically so that users can preview the corresponding effect of minimum brightness value
</Help>
</Value>
<Value type="byte" genre="config" instance="1" index="6" label="Setting maximum brightness value" min="0" max="100" value="100">
<Help>Setting maximum brightness value.
Valid value: 0 - 100, the bigger the value is, the higher the load maximum brightness is.
</Help>
</Value>
<Value type="list" genre="config" instance="1" index="7" label="Choose MOSFET driving type" size="1" value="1">
<Help>
Choose MOSFET driving type".
Default trailing edge.
</Help>
<Item label="Trailing edge" value="0"/>
<Item label="Leading edge" value="1"/>
</Value>
<Value type="list" genre="config" instance="1" index="8" label="External switch type" size="1" value="1">
<Help>
Choose external switch type.
Default normal on/off switch.
</Help>
<Item label="Push button switch" value="0"/>
<Item label="normal on/off switch" value="1"/>
<Item label="3-way switch" value="2"/>
</Value>
<Value type="list" genre="config" instance="1" index="9" label="External switch to be added to and removed from a network" size="1" value="1">
<Help>Enable/disable external switch to be added to and removed from a network.
When enables this function, triple press the external switch within 1.5 seconds to be added to or removed from a net-work.
Default Enabled.
</Help>
<Item label="Disable" value="0"/>
<Item label="Enable" value="1"/>
</Value>
<Value type="list" genre="config" instance="1" index="10" label="Detect load after re-power on" size="1" value="0">
<Help>
Enable/disable to detect load after re-power on (detect load type, minimum brightness, maximum brightness)
</Help>
<Item label="Disable" value="0"/>
<Item label="Enable to detect every time after re-power on" value="1"/>
<Item label="Enable to detect only after first re-power on" value="2"/>
</Value>
<Value type="list" genre="config" instance="1" index="11" label="Wiring type" size="1" read_only="true" value="0">
<Help>
Wiring type
</Help>
<Item label="Unknown" value="0"/>
<Item label="2 Wire With No Neutral" value="1"/>
<Item label="3 Wire With Neutral" value="2"/>
</Value>
<Value type="list" genre="config" instance="1" index="12" label="Load type" size="1" read_only="true" value="0">
<Help>
Load type
</Help>
<Item label="Unknown" value="0"/>
<Item label="Resistive" value="1"/>
<Item label="Inductive" value="2"/>
<Item label="Capacitive" value="3"/>
</Value>
<Value type="list" genre="config" instance="1" index="13" label="Over current protection" size="1" value="1">
<Help>
Enable/disable over current protection (over 1.5A for 20 seconds continuously)
</Help>
<Item label="Disable" value="0"/>
<Item label="Enable" value="1"/>
</Value>
<Value type="short" genre="config" instance="1" index="14" label="Power automatic report absolute threshold" size="2" units="W" value="10">
<Help>
Power automatic report absolute threshold, unit is W.
When power changes above the absolute threshold, immediately report current power value
</Help>
</Value>
<Value type="byte" genre="config" instance="1" index="15" label="Power automatic report percentage threshold" size="1" units="%" value="20">
<Help>
Power automatic report percentage threshold, unit is %.
When power changes above the percentage threshold, immediately report current power value
</Help>
</Value>
<Value type="int" genre="config" instance="1" index="21" label="Power metering automatich report time cycle" size="4" units="second" value="600">
<Help>
Power metering automatic report time cycle, unit is second.
Valid time cycle value: 5-2678400, when set as 0 report function is disabled
</Help>
</Value>
<Value type="int" genre="config" instance="1" index="22" label="Energy metering automatich report time cycle" size="4" value="1800">
<Help>
Energy metering automatic report time cycle, unit is second.
Valid time cycle value: 5-2678400, when set as 0 report function is disabled
</Help>
</Value>
<Value type="int" genre="config" instance="1" index="23" label="Energy metering automatich report time cycle" size="4" value="0">
<Help>
Voltage metering automatic report time cycle, unit is second.
Valid time cycle value: 5-2678400, when set as 0 report function is disabled
</Help>
</Value>
<Value type="int" genre="config" instance="1" index="24" label="Current metering automatich report time cycle" size="4" value="0">
<Help>
Current metering automatic report time cycle, unit is second.
Valid time cycle value: 5-2678400, when set as 0 report function is disabled
</Help>
</Value>
</CommandClass>
<!-- Association Groups -->
<CommandClass id="133">
<Associations num_groups="3">
<Group index="1" max_associations="1" label="Lifeline"/>
<Group index="2" max_associations="8" label="On/Off"/>
<Group index="3" max_associations="8" label="Dimmer"/>
</Associations>
</CommandClass>
</Product>