ZME_WALLC-S.xml
117 lines (113 loc) · 8.57 KB
/
ZME_WALLC-S.xml
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
<?xml version="1.0" encoding="utf-8"?>
<Product xmlns='https://github.com/OpenZWave/open-zwave' Revision="3">
<!-- Z-Wave.Me: ZME_WALLC-S Secure Wall Controller -->
<MetaData>
<MetaDataItem name="OzwInfoPage">http://www.openzwave.com/device-database/0115:0101:0100</MetaDataItem>
<MetaDataItem name="ProductPic">images/zwave.me/zme_wallc_s.png</MetaDataItem>
<MetaDataItem id="0101" name="ZWProductPage" type="0100">https://products.z-wavealliance.org/products/1086/</MetaDataItem>
<MetaDataItem id="0101" name="FrequencyName" type="0100">CEPT (Europe)</MetaDataItem>
<MetaDataItem name="ResetDescription">Use this procedure only if the primary controller is missing or otherwise inoperable.
(1) Turn the device into Management Mode by keeping all four buttons pushed for 5 seconds, (2) click on Button 3, (3) keep button 4 pushed for 4 seconds.</MetaDataItem>
<MetaDataItem name="ExclusionDescription">Re-Inclusion and Exclusion are performed by pushing button 1 in management mode. Pushing all four buttons for 5 sec. turns the device into management mode (indicated by blinking green LED).</MetaDataItem>
<MetaDataItem id="0101" name="Identifier" type="0100">ZME_WALLC-S</MetaDataItem>
<MetaDataItem name="ProductManual">https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/1086/ZME_WALLC-S-Manual.pdf</MetaDataItem>
<MetaDataItem name="WakeupDescription"> (1) Turn the device into Management Mode by keeping all four buttons pushed for 5 seconds, (2) click on Button 2. </MetaDataItem>
<MetaDataItem name="InclusionDescription">Place your primary controller in inclusion mode by following the manufacturer's instructions, then activate inclusion on the wall controller by pressing any one of the four buttons for one second. Inclusion mode is indicated by the red/green blinking of the LEDs until the timeout occurs after 10 seconds.</MetaDataItem>
<MetaDataItem name="Description">The Z-Wave.Me Wall Controller is a Z-Wave device that can both control other Z-Wave devices and activate scenes. Although it is controlling other devices, the Wall Controller cannot act as Z-Wave network controller (primary or secondary) and will always need a Z-Wave network controller to be included into a Z-Wave network. The device can be used in different modes that are selected by configuration parameters:
Control of groups of other Z-Wave devices using 'ON', 'OFF' and Dim commands.
Activation of predefined scenes in Gateways or other Z-Wave devices.
This device support secure communication when included by a controller that also supports secure communication. </MetaDataItem>
<MetaDataItem name="Name">ZME_WALLC-S Secure Wall Controller</MetaDataItem>
<ChangeLog>
<Entry author="Nouknouk - nouknouk@gmail.com" date="08 Dec 2020" revision="3">Initial Metadata</Entry>
</ChangeLog>
</MetaData>
<!-- Configuration Parameters -->
<CommandClass id="112">
<Value type="list" index="1" genre="config" label="Button 1 and 3 pair mode" units="" min="0" max="2" size="1" value="1">
<Help>In separate mode button 1 works with group A, button 3 with groups C. Click is On, Hold is dimming Up, Double click is Off, Click-Hold is dimming Down. In pair button 1/3 are Up/Down correspondingly. Click is On/Off, Hold is dimming Up/Down. Single clicks works with group A, double click with group C.</Help>
<Item label="Separately" value="0" />
<Item label="In pair without double clicks (Default)" value="1" />
<Item label="In pair with double clicks" value="2" />
</Value>
<Value type="list" index="2" genre="config" label="Button 2 and 4 pair mode" units="" min="0" max="2" size="1" value="1">
<Help>In separate mode button 2 works with control group B, button 4 with control group D. Click is On, Hold is dimming Up, Double click is Off, Click-Hold is dimming Down. In pair button B/D are Up/Down correspondingly. Click is On/Off, Hold is dimming Up/Down. Single clicks works with group B, double click with group D.</Help>
<Item label="Separately" value="0" />
<Item label="In pair without double clicks (Default)" value="1" />
<Item label="In pair with double clicks" value="2" />
</Value>
<Value type="list" index="11" genre="config" label="Command to Control Group A" units="" min="0" max="8" size="1" value="8">
<Help>This parameter defines the command to be sent to devices of control group A when the related button is pressed</Help>
<Item label="Disabled" value="0" />
<Item label="Switch On/Off and Dim (send Basic Set and Switch Multilevel)" value="1" />
<Item label="Switch On/Off only (send Basic Set)" value="2" />
<Item label="Switch All" value="3" />
<Item label="Send Scenes" value="4" />
<Item label="Send Preconfigured Scenes" value="5" />
<Item label="Control DoorLock" value="7" />
<Item label="Central Scene to Gateway (Default)" value="8" />
</Value>
<Value type="list" index="12" genre="config" label="Command to Control Group B" units="" min="0" max="8" size="1" value="8">
<Help>This parameter defines the command to be sent to devices of control group B when the related button is pressed</Help>
<Item label="Disabled" value="0" />
<Item label="Switch On/Off and Dim (send Basic Set and Switch Multilevel)" value="1" />
<Item label="Switch On/Off only (send Basic Set)" value="2" />
<Item label="Switch All" value="3" />
<Item label="Send Scenes" value="4" />
<Item label="Send Preconfigured Scenes" value="5" />
<Item label="Control DoorLock" value="7" />
<Item label="Central Scene to Gateway (Default)" value="8" />
</Value>
<Value type="list" index="13" genre="config" label="Command to Control Group C" units="" min="0" max="8" size="1" value="8">
<Help>This parameter defines the command to be sent to devices of control group C when the related button is pressed</Help>
<Item label="Disabled" value="0" />
<Item label="Switch On/Off and Dim (send Basic Set and Switch Multilevel)" value="1" />
<Item label="Switch On/Off only (send Basic Set)" value="2" />
<Item label="Switch All" value="3" />
<Item label="Send Scenes" value="4" />
<Item label="Send Preconfigured Scenes" value="5" />
<Item label="Control DoorLock" value="7" />
<Item label="Central Scene to Gateway (Default)" value="8" />
</Value>
<Value type="list" index="14" genre="config" label="Command to Control Group D" units="" min="0" max="8" size="1" value="8">
<Help>This parameter defines the command to be sent to devices of control group D when the related button is pressed</Help>
<Item label="Disabled" value="0" />
<Item label="Switch On/Off and Dim (send Basic Set and Switch Multilevel)" value="1" />
<Item label="Switch On/Off only (send Basic Set)" value="2" />
<Item label="Switch All" value="3" />
<Item label="Send Scenes" value="4" />
<Item label="Send Preconfigured Scenes" value="5" />
<Item label="Control DoorLock" value="7" />
<Item label="Central Scene to Gateway (Default)" value="8" />
</Value>
<Value type="list" index="21" genre="config" label="Send the following Switch All commands" units="" min="1" max="255" size="1">
<Item label="Switch off only (Default)" value="1" />
<Item label="Switch on only" value="2" />
<Item label="Switch all on and off" value="255" />
</Value>
<Value type="list" index="22" genre="config" label="Invert buttons" units="" min="0" max="1" size="1">
<Item label="No (default)" value="0" />
<Item label="Yes" value="1" />
</Value>
<Value type="list" index="25" genre="config" label="Blocks wakeup even when wakeup interval is set" units="" min="0" max="1" size="1" value="1">
<Help>If the KFOB wakes up and there is no controller nearby, several unsuccessful communication attempts will drain battery</Help>
<Item label="Wakeup is blocked" value="0" />
<Item label="Wakeup is possible if configured accordingly. (Default)" value="1" />
</Value>
<Value type="list" index="30" genre="config" label="Send unsolicited Battery Report on Wake Up" units="" min="0" max="1" size="1" value="1">
<Item label="No" value="0" />
<Item label="To same node as wake up notification (Default)" value="1" />
<Item label="Broadcast to neighbours" value="2" />
</Value>
</CommandClass>
<!-- Association Groups -->
<CommandClass id="133">
<Associations num_groups="5">
<Group index="1" max_associations="10" label="Life line"/>
<Group index="2" max_associations="10" label="Group A"/>
<Group index="3" max_associations="10" label="Group B"/>
<Group index="4" max_associations="10" label="Group C"/>
<Group index="5" max_associations="10" label="Group D"/>
</Associations>
</CommandClass>