GC-TBZ48.xml
257 lines (257 loc) · 10.8 KB
/
GC-TBZ48.xml
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
<Product Revision="3" xmlns="https://github.com/OpenZWave/open-zwave">
<CommandClass id="67">
<Instance index="1"/>
<Value genre="user" index="1" instance="1" label="Heating 1" read_only="false" type="decimal" write_only="false"/>
<Value genre="user" index="2" instance="1" label="Cooling 1" read_only="false" type="decimal" write_only="false"/>
<Compatibility>
<Base>0</Base>
<CreateVars>true</CreateVars>
</Compatibility>
</CommandClass>
<CommandClass id="112">
<Value genre="config" index="1" label="System Type" max="1" min="0" size="1" type="list" units="" value="0">
<Help>
0 = Standard, 1 = Heat Pump
</Help>
<Item label="Standard" value="0"/>
<Item label="Heat Pump" value="1"/>
</Value>
<Value genre="config" index="2" label="Fan Type" max="1" min="0" size="1" type="list" units="fahrenheit" value="0">
<Help>
0 = Gas (no fan w/Heat), 1 = Electric (Fan w/Heat)
</Help>
<Item label="Gas" value="0"/>
<Item label="Electric" value="1"/>
</Value>
<Value genre="config" index="3" label="Change Over Type" max="1" min="0" size="1" type="list" units="" value="0">
<Help>
0 = w/Cool, 1 = w/Heat
</Help>
<Item label="w/Cool" value="0"/>
<Item label="w/Heat" value="1"/>
</Value>
<Value genre="config" index="4" label="2nd Stage Heat Enable" max="1" min="0" size="1" type="list" units="" value="0">
<Help>
0 = no 2nd stage heat, 1 = 2nd stage heat
</Help>
<Item label="w/Cool" value="0"/>
<Item label="w/Heat" value="1"/>
</Value>
<Value genre="config" index="5" label="Aux Heat Enable" max="1" min="0" size="1" type="list" units="" value="0">
<Help>
0 = no aux heat, 1 = aux heat enabled
</Help>
<Item label="Disabled" value="0"/>
<Item label="Enabled" value="1"/>
</Value>
<Value genre="config" index="6" label="2nd Stage Cool Enable" max="1" min="0" size="1" type="list" units="" value="0">
<Help>
0 = no 2nd stage cool, 1 = 2nd stage cool
</Help>
<Item label="Disabled" value="0"/>
<Item label="Enabled" value="1"/>
</Value>
<Value genre="config" index="7" label="Temperature Unit" max="1" min="0" size="1" type="list" units="" value="1">
<Help>
0 = Celsius, 1 = Fahrenheit
</Help>
<Item label="Celsius" value="0"/>
<Item label="Fahrenheit" value="1"/>
</Value>
<Value genre="config" index="8" label="Minimum Off Time" max="9" min="5" size="1" type="byte" units="minutes" value="5">
<Help>
Sets the Minimum Off Time (MOT) delay before another heating/cooling cycle can begin
</Help>
</Value>
<Value genre="config" index="9" label="Minimum Run Time" max="9" min="3" size="1" type="byte" units="minutes" value="3">
<Help>
Sets the Minimum Run Time (MRT) delay before a heating/cooling cycle can turn of
</Help>
</Value>
<Value genre="config" index="10" label="Setpoint H/C Delta" max="15" min="3" size="1" type="byte" units="fahrenheit" value="3">
<Help>
Sets the minimum separation between heating and cooling setpoints
</Help>
</Value>
<Value genre="config" index="11" label="H Delta Stage 1 ON" max="6" min="1" size="1" type="byte" units="fahrenheit" value="1">
<Help>
Sets the delta from setpoint that stage 1 heating starts
</Help>
</Value>
<Value genre="config" index="12" label="H Delta Stage 1 OFF" max="5" min="0" size="1" type="byte" units="fahrenheit" value="0">
<Help>
Sets the delta from setpoint that stage 1 heating stops
</Help>
</Value>
<Value genre="config" index="13" label="H Delta Stage 2 ON" max="7" min="2" size="1" type="byte" units="fahrenheit" value="2">
<Help>
Sets the delta from setpoint that stage 2 heating starts
</Help>
</Value>
<Value genre="config" index="14" label="H Delta Stage 2 OFF" max="6" min="0" size="1" type="byte" units="fahrenheit" value="0">
<Help>
Sets the delay from setpoint that stage 2 heating stops
</Help>
</Value>
<Value genre="config" index="15" label="H Delta Aux ON" max="8" min="3" size="1" type="byte" units="fahrenheit" value="3">
<Help>
Sets the delta from setpoint that stage 3 heating starts
</Help>
</Value>
<Value genre="config" index="16" label="H Delta Stage 2 OFF" max="7" min="0" size="1" type="byte" units="fahrenheit" value="0">
<Help>
Sets the delta from setpoint that stage 3 heating stops
</Help>
</Value>
<Value genre="config" index="17" label="C Delta Stage 1 ON" max="6" min="1" size="1" type="byte" units="fahrenheit" value="1">
<Help>
Sets the delta from setpoint that stage 1 cooling starts
</Help>
</Value>
<Value genre="config" index="18" label="C Delta Stage 1 OFF" max="5" min="0" size="1" type="byte" units="fahrenheit" value="0">
<Help>
Sets the delta from setpoint that stage 1 cooling stops
</Help>
</Value>
<Value genre="config" index="19" label="C Delta Stage 2 ON" max="7" min="2" size="1" type="byte" units="fahrenheit" value="2">
<Help>
Sets the delta from setpoint that stage 2 cooling starts
</Help>
</Value>
<Value genre="config" index="20" label="C Delta Stage 2 OFF" max="6" min="0" size="1" type="byte" units="fahrenheit" value="0">
<Help>
Sets the delta from setpoint that stage 2 cooling stops
</Help>
</Value>
<Value genre="config" index="23" label="Lifeline Association Group Report To Send" max="65535" min="0" size="4" type="int" value="8319">
<Help>
Report to send to the Lifeline Association Group upon change in thermostat state.
Bitmask values:
1 = Temperature
2 = Heat Setpoint
4 = Cool Setpoint
8 = Thermostat Heat/Cooling Mode
16 = Fan Mode
32 = Fan State
64 = Operating State
128 = Schedule (send CC parameter 38)
256 = Setback (send CC parameter 40)
512 = Run Hold (send CC parameter 39)
1024 = Display Lock (send CC parameter 24)
8192 = Battery Level
16834 = Mechanical Relay State (send CC parameter 21)
32768 = Thermostat State Config (send CC parameter 22)
</Help>
</Value>
<Value genre="config" index="24" label="Display Lock" max="1" min="1" size="1" type="list" units="" value="0">
<Help>
Display Lock
</Help>
<Item label="Unlocked" value="0"/>
<Item label="Locked" value="1"/>
</Value>
<Value genre="config" index="26" label="Backlight Timer" max="30" min="10" size="1" type="byte" units="seconds" value="20">
<Help>
Sets the time from last button press that the backlight will turn OFF
</Help>
</Value>
<Value genre="config" index="33" label="Max Heat Setpoint" max="109" min="30" size="1" type="byte" units="degrees" value="90">
<Help>
Sets the maximum heating setpoint value
</Help>
</Value>
<Value genre="config" index="34" label="Min Cool Setpoint" max="112" min="33" size="1" type="byte" units="degrees" value="61">
<Help>
Sets the minimum cooling setpoint value
</Help>
</Value>
<Value genre="config" index="38" label="Schedule Enable" max="1" min="0" size="1" type="list" units="" value="0">
<Help>
Enable or disable thermostat's local scheduler
</Help>
<Item label="Disabled" value="0"/>
<Item label="Enabled" value="1"/>
</Value>
<Value genre="config" index="39" label="Run/Hold Mode" max="1" min="0" size="1" type="list" units="" value="0">
<Help>
0 = Hold, 1 = Run
</Help>
<Item label="Hold" value="0"/>
<Item label="Run" value="1"/>
</Value>
<Value genre="config" index="40" label="Setback Mode" max="2" min="0" size="1" type="list" units="" value="0">
<Help>
0 = No setback, 2 = Un-occupied mode
</Help>
<Item label="No Setback" value="0"/>
<Item label="Unoccupied Mode" value="2"/>
</Value>
<Value genre="config" index="41" label="Un-Occupied HSP" max="109" min="30" size="1" type="byte" units="degrees" value="62">
<Help>
Heat Setpoint for Unoccupied mode
</Help>
</Value>
<Value genre="config" index="42" label="Un-Occupied CSP" max="112" min="33" size="1" type="byte" units="degrees" value="80">
<Help>
Cool Setpoint for Unoccupied mode
</Help>
</Value>
<Value genre="config" index="43" label="Remote Sensor 1 Node Number" max="252" min="0" size="1" type="byte" units="">
<Help>
Node number for Remote Sensor 1
</Help>
</Value>
<Value genre="config" index="46" label="Remote Sensor 1 Temperature" max="112" min="0" size="1" type="byte" units="degrees">
<Help>
Temperature of Remote Sensor 1
</Help>
</Value>
<Value genre="config" index="48" label="Internal Sensor Temp Offset" max="7" min="-7" size="1" type="byte" units="degrees" value="0">
<Help>
Internal Sensor Temperature Offset
</Help>
</Value>
<Value genre="config" index="49" label="R1 Sensor Temp Offset" max="7" min="-7" size="1" type="byte" units="degrees" value="0">
<Help>
R1 Sensor Temperature Offset
</Help>
</Value>
<Value genre="config" index="52" label="Filter Timer" max="4000" min="0" size="2" type="short" units="hours" value="4000">
<Help>
Timer to let know when to change or clean the filter
</Help>
</Value>
<Value genre="config" index="53" label="Max Filter Timer" max="4000" min="0" size="2" type="short" units="hours" value="44">
<Help>
Maximum allowed value for filter timer
</Help>
</Value>
<Value genre="config" index="54" label="Heat Timer" max="4000" min="0" size="2" type="short" units="hours" value="0">
<Help>
Heat Timer in hours
</Help>
</Value>
<Value genre="config" index="55" label="Cool Timer" max="4000" min="0" size="2" type="short" units="hours" value="0">
<Help>
Cool Timer in hours
</Help>
</Value>
<Value genre="config" index="61" label="Fan Purge Heat" max="90" min="0" size="1" type="byte" units="seconds" value="0">
<Help>
Fan purge period for Heat mode
</Help>
</Value>
<Value genre="config" index="62" label="Fan Purge Cool" max="90" min="0" size="1" type="byte" units="hours" value="0">
<Help>
Fan purge period for Cool mode
</Help>
</Value>
</CommandClass>
<CommandClass id="133">
<Associations num_groups="3">
<Group index="1" label="Lifeline" max_associations="5"/>
<Group index="2" label="Cool" max_associations="5"/>
<Group index="3" label="Heat" max_associations="5"/>
</Associations>
</CommandClass>
</Product>