The initial calibration shows counter values of each clocks with large offset. #33

Open
changtengfei opened this issue Jun 29, 2022 · 0 comments

Comments

@changtengfei
Copy link
Contributor

changtengfei commented Jun 29, 2022

In the attached image, it shows the printed out counter value with a large offset.

I.e.

HF = 783192 2M=80369 LC=97714 IF counter = 637749
(should be 2000000) (should be 200000) (should be 250260) (should be 1600000)

image (1)