Daikin2MQTT User Guide

Contents

Build from Source

daikin2mqtt is written in Go - you will need Go 1.16 or later installed to build the software.

Having either git cloned the repo, or downloaded and uncompressed a source package, simply...

cd daikin2mqtt                      # or whichever directory you placed the files
go build cmd/daikin2mqtt.go

Configuration

Configuration is performed via a single TOML file, when you start the program you must pass it the name of your configuration file eg.

./daikin2mqtt -conf /home/ha_user/daikin2mqtt.toml

Here is a sample configuration showing all available options...

# All configuration options
# All entries are required unless otherwise specified

[mqtt]
base_topic = "daikin2mqtt"          # MQTT base topic
broker = "localhost"                # MQTT broker
port = 1883                         # MQTT port
username = ""                       # MQTT broker user (use "" for none)
password = ""                       # MQTT broker password (use "" for none)

[daikin]
discovery_timeout = 5               # Seconds to wait for units to respond
rediscovery_minutes = 20            # Minutes between unit discovery attempts
update_period = 60                  # Seconds pause (s) between regular updates from inverters

[[inverter]]
  mac = "C0E434E69F27"              # The unpunctuated MAC address of the unit
  friendly_name = "Steve_Office"    # Will form part of the MQTT topic
  
[[inverter]]
  mac = "C0E434E60BC6"             
  friendly_name = "Spare_Bedroom"  

Add an [[inverter]] section for every unit you want to monitor/control.

A file similar to the above named configuration.toml is in the examples directory.

MQTT Topics

N.B. Henceforth we assume you have set the base_topic to "daikin2mqtt".

There are three main types of message topic:

  1. Device status updates and responses to requests are published to daikin2mqtt/FRIENDLY_NAME/<type>
  2. Requests for inverter state via daikin2mqtt/FRIENDLY_NAME/get
  3. Commands you send to inverters via daikin2mqtt/FRIENDLY_NAME/set

On start-up, the simple string "Started" is sent to the daikin2mqtt/status topic.

Currently, daikin2mqtt does not store live data internally - each time a get request is received the appropriate unit is queried for the data.

Get Subtopics

The subtopics for get are basic, controls, [online ??? - tbd], and sensors

Eg. daikin2mqtt/Steves_Room/get/sensors

Set Subtopics

The only subtopic currently defined for set is controls, you must supply a control message.

Eg. daikin2mqtt/Spare_Bedroom/set/controls

  • The JSON-formatted control message may contain any number of the fields shown below
  • Setting the timestamp is meaningless and will be ignored
  • You can set just one, several, or all of the controls
  • Unset controls will be left as-is

In order to simplify use with dashboards (eg. Node-Red), after a successful set, daikin2mqtt will automatically requery the inverter controls and publish a controls message.

MQTT Messages

Messages (payloads) are all in JSON format.

Basic

{
    "firmware_version": "<string>",
    "power":            true|false,
    "error":            <integer>,
    "adaptor_led":      true|false,
    "holiday_mode":     true|false,
    "group_mode":       true|false,
    "group_name":       "<string>",
    "timestamp":        "<HH:MM:SS>"
}

The timestamp records when the data were collected from the unit.

Controls

Published to subtopic /controls

{
    "power":            true|false,
    "mode":             "<mode-string>",
    "set_temp":         <integer>,
    "set_humidity":     <integer>,
    "fan_rate":         "<fan-rate-string>",
    "fan_sweep":        "<fan-sweep-string>",
    "timestamp":        "<HH:MM:SS>"
}   

Where:

<mode-string> is one of "AUTO", "AUTO 1", "DEHUMIDIFY", "COOL", "HEAT", "MODE 5", "FAN", "AUTO 2"

<fan-rate-string> is one of "AUTO", "SILENT", "LEVEL_1", ... "LEVEL_5"

<fan-sweep-string> is one of "OFF", "VERTICAL", "HORIZONTAL", "BOTH"

In dehumidify mode, some units return a set temperature of "M", daikin2mqtt will return 0 in this case.

In some modes, set temperature and set humidity are reported as "--", daikin2mqtt will return 0 in these cases.

The timestamp records when the data were collected from the unit. Do not include the timestamp field in a set/controls request.

Sensors

Published to subtopic /sensors

{
    "unit_temp":        <float, 1 d.p.>,
    "unit_humidity":    <integer>,
    "ext_temp":         <float, 1 d.p.>,
    "error":            <integer>,
    "timestamp":        "<HH:MM:SS>"
}

Not all units return external temperatures (some only when powered on), daikin2mqtt will return a dummy value of -99.0 when no temperature is reported.

Likewise, not all units report humidity, daikin2mqtt will return a value of 0 if none is reported.

The timestamp records when the data were collected from the unit.