What steps will reproduce the problem?
1. In Analysis open up Structure --> CING
2. After creating a run, in the Run Settings tab deselect some residues.
3. Submit the Project.
What is the expected output? What do you see instead?
The deselected residues should be ignored
What version of the product are you using? On what operating system?
Analysis 2.2.2
Please provide any additional information below.
A sample project created by Analysis when submitting a project is at:
http:/www2.ccpn.ac.uk/cing/CcpnCourse_Cing.tgz
This has the first seven residues deselected, as you can see in the
ccp/nmr/NmrCalc/auto***.xml file.
The Cing residue output is at:
https://nmr.cmbi.ru.nl/tmp/cing/ccpnAp/HmxzU9/__CcpnCourse3c.cing/GI/HTML/Dihedr
als/DihedralByResidue.html#_top
Original issue reported on code.google.com by wab...@gmail.com on 1 May 2013 at 10:19
The text was updated successfully, but these errors were encountered:
Thanks Wayne for submitting the issue here.
I think we might not have coded for the functionality to take CCPN's residue
selection. I do know it's a parameter in the GUI and in the robot interface you
can give when submitting to iCing though.
So I think you're asking for an enhancement.
Original comment by jurge...@gmail.com on 15 May 2013 at 5:59