Diagnosing pymodbus connection issues #514
Comments
configuration.yaml
|
Firstly, I apologise for being so lazy. I thought that might work, but I'm so stressed talking to SolarEdge and trying to resolve things I panicked. As promised, I got the following logs:
Which are illuminating. They confirm my telnet test that the port is open but there's nothing coming back. I found this line interesting:
But it only occurred once. Is there any other illumination you can provide before I pass on my interpretation to SolarEdge. Again, I'm conscious this is not formally supported by them so the more insight I can pass on to them the more likely there are to be able to help rectify the issue. To be clear, the communications were working fine until SolarEdge made some parameter changes to my inverters, so I strongly suspect the issue is at their end (particular as the time the communication stopped coincides with the time they made the changes). |
I would try giving the inverter a cold boot if you haven't already done that. Turn the red switch to 0, wait for it to shut down, then open the DC disconnect, then open the AC disconnect. The three light tower should turn off. Wait 30 seconds then turn it back on starting with the AC disconnect. |
Yeah, we tried resetting the new mode flag followed by a comms board reboot; and I previously tried a cold boot whilst in the new mode. I've suggested the next step is to try changing the new mode back and doing a cold boot - but they have to make the change first and will want to watch what happens. I'll bounce the log back to them now. |
This might also be a connection race from an uncaught exception during setup; I've corrected that in PR #515 and I'll push a pre release shortly for you to try. |
Release v2.4.9-pre.4 contains the change. |
OK, I'll hold on to try that first. I don't want it to be our issue as I've got a really good line to their engineers right now, and they're interested in helping resolve issues, so I don't want to lose that goodwill. I'll keep you informed of any info I get as I'm quite a complex site for them, and they're interested in debugging some of their new functionality that is currently being extended to multi-inverter sites. That includes proper HomeBackup support for multi-inverter multi-battery sites, that I tested today and allowed both my inverters to power the home in a full backup scenario (grid off), I was running ~9kW of load with no grid connection. |
Basically what wasn't happening is when an IO error occurred during setup it wasn't calling disconnect. It would then loop back around holding onto a possibly dead connection. What's supposed to happen if we get an IO error is force a disconnect and open a new connection on the next retry. Of course the inverter could still not be responding, but at least I can say for sure it's not because an old connection is being held onto. If they happen to tell you about any modbus registers that aren't documented, let me know and I can add them to the integration. |
OK, I ran using that and I didn't see any
As you can see, you are now correctly catching the error and reconnecting. I recommend you dump the error to the log as an error as well as raising the However, I'm still not getting a response. The only new register may be the |
During setup when the configuration is first loaded (or reloaded), Home Assistant will turn all errors into Older versions of Home Assistant would show this error more prominently in the integration panel, but at some point it was decided to hide it the hover tooltip. I don't remember if it would also log or not, but it was a decision from the HA core team to make setup errors more hidden. |
I checked the core code, they are disabling failure logging at that stage: https://github.com/home-assistant/core/blob/dev/homeassistant/helpers/update_coordinator.py#L279 |
Yeah, it doesn't also log it. I appreciate that is the HA Devs choice. Is it considered anti-pattern to also put the error in the log? Personally, I'd put the full error in the log and put a friendly error in the Hub like 'A modbus communication error occurred'. However it's whatever you prefer. If you want to put a feature branch with an option for the new mode, rather than a beta that would affect everyone, I can patch my code locally? |
I would need to know the modbus register address, size, and type. 1404 is way outside the holding register range that starts at 40000. |
Yeah I’m just starting to read up on the Sun Spec. I’ll see if I can get more info, but I’m not hugely optimistic. Ofc I’ll share it if I do. |
The plot thickens, I sent raw data to the port and could see that it responded with zero-length data. I changed the unit identifier to '02' and voila, I got data back. Checking the SetApp, sure enough their engineers have changed the device ID from 1 to 2. However, I can't find how to easily change the Device ID/IP Address/Port of the existing hub? I've seen a repair ticket appear after many hours which allows you do that, but there's nowhere I can find to do it now. The configuration menu does not expose those settings, and I can't temporarily disable the existing hub and add a new one to test. I have a large system and am loathe to delete the existing hub and have to go through and ensure all the entity ids are correct later if I can just change the Device ID somewhere. Possibly I'm being blind, but if you can point me in the right direction that would be great. |
OK, I just deleted the hub and added a new one with Device ID 2. The setup still fails, but I'm getting a lot more logs now:
I can see it interrogates the primary inverter and then tries to talk to Device ID 3 but gets no response. This reminds me of the previous issues relating to non-consecutive modbus device IDs... Sadly, everytime SEDG muck around with my system they force these IDs back to defaults which may not be non-consecutive. (see #368). It might be worth changing the hub failure error to suggest checking the DeviceID when it gets no response from an open connection? Also, I'm wondering if it would be possible to auto scan the device IDs, given that sending the wrong ID results in an immediate empty response? |
Great news! It turns out that they set the Device ID for both the master and slave inverters to '2'!!! I've queried why they did that - I hope it was just engineers messing around with things they didn't understand. Setting the master back to 1 has allowed me to re-add the hub. I had previously renamed all the second In the meantime, I've changed all my references to use the default naming so it isn't so difficult to remove and re-add a hub. This has been a very informative issue, as it's forced me to finally dig into the Modbus specs and understand them better. When I finish all my renovations and get my head above water, I'll try to contribute more time to helping with this fantastic project. Thank you for your help. |
I did try naming like that, but reverted it for reasons I can't remember now. It might be in the history. The repair isn't raised during setup, but its easy to change that. |
Scanning all possible modbus addresses isn't really practical. With minimum timeouts would take at least 12 minutes, and nobody is going to wait that long for HA to finish startup or add an entry and not think something is broken (if HA would even allow that before forcing a timeout). Modbus protocol doesn't provide a way to detect duplicate ID. You can't assume that no response means duplicate ID, it can just mean no response too. I monitor my inverters and occasionally they will do the same non-response thing for a cycle. |
For what it's worth when my system was installed the installers left unit ID settings set to '1', so it's possible that in general it's not well understood why that setting would need to be unique per inverter. Duplicate unit ID does not appear to affect Solaredge's proprietary leader/follower protocol or their monitoring platform. |
It is true there are 247 possible device IDs (1->247) and at 3s timeout that would be just over 12 minutes in the worst case. However, SolarEdge runs on RS485 which I believe has a limit of 32 connected devices - though there's no guarantee that those IDs are consecutive, they are almost always clumped in the first 32 id spaces. Further, in my testing, when I pinged a missing device ID, I got an instant zero-length response - sensing this would allow immediate moving on to the next ID in a 'Fast Scan'. A timeout would usually indicate a comms failure and the scan could optionally abort immediately. As it is unlikely that most devices would have an ID set above > 32, and, most of the time, and unassigned IP will immediately respond with an empty packet we can do an initial fast scan extremely quickly for the vast majority of scenarios. If the scan reports progress as it goes, the user can click stop when all the devices are found. Alternatively, they can enter the target device count before commencing a scan. It's also not a requirement that people use the 'fast scan' if we provide a UI for manually entering Device IDs (which the fast scan populates automatically), they can have a Scan button to optionally perform a scan. We can also have a slower scan that rigorously checks from 1->247 with full timeouts if necessary, and that would take 12mins. The point is that such a function would probably work very quickly for the vast majority of installs. SolarEdge has told me that the vast majority of sites are one inverter and one battery max, and the Device ID is likely to be < 4. Scanning automatically for device IDs and supporting non-consecutive IDs will make it much easier for less technical users. Anyway, this is a suggestion, and I may be able to have a crack at implementing and testing it in the future if you're interested. If you think it's worth it I can write up a clean feature request for garnering interest?
Yes, in fact the primary inverter was responding fine on the ID, and the follower was hidden, there was no way to see there was actually a duplicate ID. A duplicate ID did not cause a non-response; the empty response was on ID '1', which was empty (as it had been moved to collide on '2'). As you can see from the logs, the primary inverter is the one responding on '2' whilst the duplication was in effect. A scan whilst a duplicate ID is set would result in only the master inverter being found, and the follower being unavailable - in such a scenario the UI could suggest using the SetApp to check that there are different Device IDs and provide a link to the wiki. It is my suspicion that distinguishing between an empty response and a lack of response will prove very fruitful in detecting an empty device ID. I suspect that when you fail to get a response on occasion on a valid ID, it is a non-response not an empty response, but that's harder to confirm as the current pymodbus doesn't log an empty response and waits for the timeout instead. A brief scan of pymodbus docs seems to indicate it can detect an empty response though, but I would need to investigate further. |
There are commercial size installations using this integration, so we can't make any assumptions about small sites. |
My inverters don't have that behavior, so that's probably dependent on the firmware version if yours do that and mine don't. |
Agreed, but I'm not. As stated above, the 32-device limit is the same on large installations, so they must use separate mod busses to exceed that. Even if that limit isn't there, the Modbus spec uses one byte and only supports 247 values. My proposal has the following non-breaking mitigations for your scenario:
As such the proposal only adds a convenience feature, it doesn't create a breaking change. If users on large sites don't want to perform a scan, or wait up to 12 minutes, they are free to not do so. I suspect for the vast majority of users a scan will be quicker, more robust and more convenient. However, this is just a proposal for discussion.
Just to confirm, the pymodbus logs do not show any empty response. I only saw that by using Packet Sender and manually sending the binary data to the TCP port. I could not see a near instant empty response come back, whereas pymodbus reported nothing and waited for the full 3s timeout. I need to check the pymodbus code to see how it handles a truly zero length packet to see if we can detect it. Have you tried hitting the TCP Modbus directly rather than through pymodbus? |
I've already been working on stuff in regards to invalid IDs from #460 and the wish list has non-consecutive IDs on it, but I've not uploaded anything yet since it's not a high priority. Modbus at its heart is broadcast-response and I have seen data from inverters where their "normal" is 1-2 seconds to respond, so 3 seconds is necessary (already on the edge of being too short). I've also seen inverters with an escalating response delay. I can't tell you the exact issue/pr but if you look through all of the closed ones it's in there somewhere. There's not much difference between Modbus TCP and RTU: you still broadcast and either you get a response or you don't. I also calculate timeouts based on number of requests and device types based on past observations, which you can see the total calculated timeout if you turn on debugging. There are four possibilities when sending a modbus request:
So for the case of auto detecting IDs for setup, scanning the first 32 addresses with a 3 second delay and 3 retry attempts would be up to about 5 minutes. In reality it would probably be faster but it's not guaranteed. I work with modbus outside of this (power meters, generators, transfer switches, pumps, air handlers, etc.), but I use libmodbus in C. I have modbus simulators that I've built up over time to work with this integration especially for devices I don't have like batteries. Other connection methods are academic at best, since HA is using Python and the Pymodbus library. About the only thing external tools are useful for in my experience are scanning registers looking for undocumented stuff. Even my simulators aren't ideal because they don't have the weird problems SE stuff can randomly have. It's also on my wish list to support a serial option, so anything that's done ideally should consider the possibility for modbus RTU (the original form). It's at the bottom of the priority list though. |
I should add that I don't really care if some auto-detect takes 5 minutes to run, but I don't know how HA reacts to long running setups and end users generally want things to be instant or they complain. |
PR #518 will raise the repair issue if setup fails, previously it would just raise on connection issues post-setup. |
Thanks for the great detail! Looking through your 4 responses you don’t list an empty response though - have you not seen an empty packet in your testing. Like I said, my system gave back a near instant empty packet for unassigned IDs, which is not the same as no response. In terms of malformed responses it always a choice whether to retry (until a count or timeout) or log and move on. I can see the argument for the former - there being a bad response is a hint there is at least a device at that id so worth a retry. I appreciate that an empty response is a TCP thing though, and wouldn’t work with RTU. The 5-12 minute thing may cause a HA setup fail, that would need investigating. If they do timeout for setup there’s a strong case for a keep-alive feature request, but I acknowledge your concern. I have seen other setups that warn that it can take several minutes though, so I suspect it’s doable. It’s easy to find out with a nice long sleep anyway! As for user experience that’s pretty resolvable with good UI. I think scan functionality should be an opt in, rather than requirement, e.g. a button you press when setting a list of device IDs that warns before starting. If you know your IDs you can just enter them manually. It’s highly likely most scans would complete fairly quickly after scanning 2-5 IDs, and if the user is warned that a scan may take up to 12 minutes they’ll accept that. They can always be passed to a wiki explaining why it takes so long. I saw the PR and think that’s a great addition. Ultimately this is a great tool, and has allowed me to do some really cool smart home stuff, so thanks for all the hard work and effort. I will obviously update you if I manage to get the register number out of SEDG. I currently have some really good access so it is possible. I’ve made a strong argument for getting it, though they’re understandably going to be reluctant given the beta nature of the mode. |
A modbus frame always has its headers, id, function code, and data bytes. TCP only differs from RTU in that modbus TCP doesn't include a checksum after the data bytes because it's relying on the lower levels of TCP/IP to handle that aspect. If something send an "empty" response that would just be an I/O error as far as I understand the modbus protocol, maybe some attempts to resend the request, ultimately timing out due to no response. |
Yes.
What I saw was an empty TCP packet, (basically just a 64 byte header) which is a totally valid TCP packet - but as you say not a valid Modbus frame. It is quite distinct from no response at all, but I believe is treated like no response by pymodbus - as there is no data to decode. I didn't see it treated as an error by pymodbus, which is not surprising as it's not really part of the modbus design itself as the idea of zero length only becomes possible when the modbus protocol is embedded in a different transport protocol as with Modbus TCP. The distinction between no response and empty occurs at the TCP layer not the Modbus protocol layer. Hence I acknowledged it wouldn't help when using Modbus RTU. Technically, it is possible to distinguish such an empty TCP packet from no response, but I'm not sure if pymodbus supports that natively or just swallows the empty packet entirely (quite possible). In my testing that empty packet comes back instantly and may be a reliable indicator that the device id is unassigned, as opposed to a communication error or unresponsive slave. However, that would need careful testing and investigation. I am encouraged that the receipt of a tcp packet, albeit empty, requires the modbus server/slave to process the request and respond - unlike when it's just busy. It is not unlikely that the empty response is a result of SEDG's implementation recognising there is no device at that ID, and so having nothing to include in a response payload. An empty response would be equivalent to 'we know nothing came back' as opposed to no response being 'we're still waiting for a response'. |
The ACK is an empty packet. It's just a flag in the header and you can include response data. If you hit a known device ID I believe you get the response data in the ACK - especially if it's the first message of the connection. I will do some wireshark tests, as the tool I used wasn't as detailed. My suspicion is that you only get an empty ACK if it's the first message, which would mean opening a new connection for each query. I'll whip up some prototype scan code using the raw TCP connection to see if it works and report back. I don't want to waste your time, I've just been really busy with renovations and builders, but it's on me to proof the idea. |
I had a spare hour before the builders arrived this morning and re-learnt python as I only use it to help the nephews with their coursework normally! I created a quick scan routine here and set a timeout of 0.5s, it ran reliably on my network and found the two inverters without any issues. It didn't get a response from my meter though so I probably need a different query, which I'll look into. Obviously, a timeout of 3s would be slower. Sure enough, the ACK is only detectable in the kernel, not the sockets library. However, I found Scapy, which looks like it will give me what I want for a prototype. I'm out of time now, but I'll look at it again as soon as I can, and try a Scapy-based implementation. |
No, you do not. ACK is ACK. It's not empty it's just ACK. https://en.wikipedia.org/wiki/Transmission_Control_Protocol#Reliable_transmission This is a request and response sequence: ![]() Pymodbus in HA generates a request. We sent request to inverter, inverter's TCP/IP stack sends ACK saying hey I got your message. Modbus stack in inverter generates a response. Inverter sent a response us, so our TCP/IP stack sends ACK saying hey we got your message. ACKs are the difference between TCP and UDP. ACKs are why there's no CRC segment vs. RTU frames. The TCP/IP stack is doing that work that so modbus doesn't need to. If you're looking for ACKs you're detecting if a working TCP/IP stack exists, but that has nothing to do with modbus. |
I apologise if I'm upsetting you. I'm autistic and struggle with misunderstanding when communicating via the written word. I really hope I am not frustrating you, and I genuinely apologise if I am. It is not my intent. Feel free to close the issue if you feel its gone too far off topic. What I said was:
See TCP delayed acknowledgement For example, Linux implementations have a 'Delayed ACK' setting. This is usually set around 200ms, when a request is received, the kernel will not immediately respond with an ACK (which is just an empty TCP packet with the ACK flag set in the header, as I mentioned), but wait to see if a response is provided from the user application or higher layers (e.g. HTTP). In the vast majority of real-world cases, that response comes back in less than 200ms, so by waiting for it, it can combine the ACK + response data into a single Layer 2 packet. If the timeout is hit (or you are in 'Quick ACK' mode), it will send the empty packet with an ACK. This approach can effectively reduce network traffic by up to 50%. Windows also uses delayed ack (see this StackOverflow as an example). All that stuff is academic and will prove irrelevant (see below) except to explain my reasoning. It's been 20-30 years since I last worked on lower-layer protocols like TCP. These days, it's very much a solved problem left to kernel authors, so I fully acknowledge my memory is a little rusty on these things. When responses I got from my inverter (when using a valid Device ID) seemed to take <200ms, it reminded me of delayed ACK. The software I used made it look like they were in the same packet as the ACK, which is what I'd expect. Further, I quickly saw an empty ACK when the Device ID was unused. Based on that, I theorised that we might get away with moving on in a scan when we receive the ACK. I had an SSD fail recently, so I still needed to reinstall Wireshark. With everything else going on, I didn't have time. So, this morning, I took the time to install it and confirmed similar results to yours1 which shows me scanning device ids
In contrast, Device ID Keeping a single connection, sped things up, but the Devlice ID What this shows is:
My biggest logic error was - if I was happy to accept an empty ACK at 200ms as an acknowledgement that no device ID was found 2 then that is not practically different from us applying a 200ms3 timeout to the request! So the real question is, what is the shortest acceptable timeout to spot a potential inverter? In my testing, 0.5s has been pretty reliable - especially if I didn't care about responses from meters/non-inverters, which usually took much longer. If it wasn't ready to respond, I usually got a connection close/fail attempt, from which I could attempt a retry. Reusing the same connection tended to help the algorithm run quicker (as it didn't have to tear down and reinitiate connections each time). The following algorithm would generally find inverters very quickly:
This takes advantage of 2 observations:
In my own testing such an approach found my inverters almost all the time, and within a few seconds. You can see my script at https://github.com/thargy/modbus-scanner, that implements this chunking approach. If you want to try it for yourself. It's only a prototype (and I've not written python in ages), but it's fully functional and allows you to muck around with settings (use Anyway, sorry for the wall of text. Footnotes
|
It looks like you're using Python 3.12 specific things and my dev systems are Python 3.11 since that's what the integration requires, so I wasn't able to try it. |
Sorry, just had to learn about |
Running against my inverters total time was |
If you force it to do a comprehensive scan, it will take at least 3.5s per device ID (by default, you can change every timeout with the Command Line Options) - which is exactly what you're getting. Every time it gets a valid response in less than 3.5s it will shorten the total duration from the 865s maximum. As your time was 24.5s faster than the maximum, it must have seen some things. Of course, doing a full scan is only necessary if you don't know how many inverters you have, as the idea is to find a set number of inverters before exiting; or, if the last inverter has been perversely set as 247. So, the command line supports specifying the number of inverters (according to the algorithm I proposed). Most users will only have up to 3 inverters (e.g. one per phase), and the routine will terminate in seconds. It's reasonable to propose that anyone with >3 inverters would probably be a more advanced user anyway, and more than able to discover their IDs manually. I would propose having a comma-separated list of inverter IDs as the setup option and an adjacent button to scan for them. That button would ask for the number of inverters to find (and potentially whether to look for batteries), and have a warning that a full scan could take up to 15 minutes. Clicking the scan would show progress with a cancel option allowing them to cancel it wherever they got up. On completion/cancellation, it would populate the inverter IDs into the setup box. Most users would click the scan button, select 1-3 inverters, and it would complete in <20s. Advanced users may enter the comma-separated list of inverter IDs (or take advantage of the simple device ID parser I made, which allows syntaxes such as "1,3, 4-7") and ignore the scan functionality entirely. Even in the worst case, which I really don't think would happen in real use, the scan would take <15minutes. I hope you found this a useful contribution. Ultimately, such a system would just be a quality of life improvement for novice users. The more useful change would be the ability to support non-contiguous device IDs, which would be a precursor requirement to implementing a scan routine anyway. |
Changing the field to allow a list of addresses is relatively easy. Making it user-proof and HA config entry schema conversion for upgrades is the part that takes time. It would be considered a breaking change since changing the config schema prevents downgrades to a previous version, so it needs planning for the right time to introduce it. |
I'm not au fait with the schema or the upgrade/downgrade. In other systems, we'd handle this by adding a new configuration option and hiding the old one but keeping it in sync, so in the case of a downgrade, the old setting would still be there and be 'valid'. For example, we add a new When upgrading, we take the existing inverter count and start ID and set the new |
The most common is |
That was my configuration until I persuaded my installer to stick the meter on 3. The above algorithm handles that scenario perfectly. Two inverters chunk the device ID in chunk sizes of 3 (1.5x2), so it will fast scan 1-3 and then slow scan 1-3. Most of the time, it will find Devices 1 and 3 in less than 1.5 seconds (the fast scan) or in less than 10.5 seconds (worst case, Device ID 3 needs a slow scan). |
How does that help making 1,3 a schema downgrade? |
Because you don't support non-consecutive IDs in the current version anyway. Anyone successfully using the addon at this current version has to have set up consecutive IDs already - otherwise it won't work. A downgrade is only of benefit to such users. Those users can only set, for example '2 inverters start ID 2', which would mean IDs '2-3' if they upgrade their setup would become '2-3' and still work, and if they downgrade it will revert to start ID '2' and still work. If someone upgrades and then changes their inverter IDs then they cannot downgrade without changing those IDs back. However, most users cannot change their IDs (unless they have SetApp and understand how to use it). If they can change their IDs, they can return them to the original settings when they downgrade, to restore their original system. i.e. a downgrade only needs to restore the functionality available in that version. Does that make sense? |
That is my entire point saying this is a breaking change. |
Oh, OK, this looks like a semantic thing. That's different from what we'd usually define as a breaking change. A breaking change could potentially break an existing working system when upgrading. This doesn't, as it can upgrade all existing working systems without them stopping working. More accurately, if you change an existing module, it should be able to be placed in the wider system without breaking any existing functionality. Again, this doesn't meet that criteria. Some companies would define a breaking change to also include changes that, once applied, cannot be reversed. That view is less common but is out there. Again this wouldn't meet that loose criteria either, as we have a fully viable downgrade path for systems that can work in the downgraded version. When downgrading to today's version, you can't expect a system that doesn't work today to work. This is purely adding a new feature (IMHO), as you can upgrade from working to working and downgrade from working & not working back to working. If you upgrade a working system to take advantage of non-consecutive IDs, you must change your setup to use that. However, non-consecutive IDs are only supported from the upgraded version, so downgrading would never work. That's not a breaking change. You can't use new functionality in an old version of software, that's never been possible. I apologise my explanations are always overly verbose, but I'm trying hard to be clear and to understand your objection. |
If you're referring to
i.e. this relies on the start ID remaining in the new version and being set to the lowest ID ( |
Someone with a 1,3 setup downgrading because there's some unforeseen issue that takes time to figure out will complain about only 1 working. That's not the experience I want people to have with my integration. I don't want to see that issue report nor have to explain they need to go into setapp to change unit IDs to get something working again. The ideas are fine but there are a other things I want to do first before creating a hard line like that. That's why #460 is still open. If I'm going to add validation for one ID then naturally that can extend to checks that would allow non-consecutive IDs. It will be in 2.5.0 but not the current 2.4.x series. See this project board for the list of ideas: https://github.com/WillCodeForCats/solaredge-modbus-multi/projects/2 |
This is where I'm getting confused. Anyone with a 1,3 setup cannot be helped by downgrading, as their system cannot work on the downgraded version, and the downgraded version cannot work with a 1,3 setup (as it doesn't support non-consecutive IDs). As the system works now, anyone with a 1,3 setup will raise the issues you rightly don't want to deal with (as I did last July, as I was one of them). If you add the upgraded functionality, they will stop raising such issues as it will now work. You would not advise them to downgrade to an earlier version that doesn't support their system, and if they did it off their own back the 'make sure you're using the latest version' response is the correct one. If you advise anyone to downgrade beyond the "non-consecutive ID support" version (e.g. because of an unrelated bug in the latest version), it would be important to emphasise that versions before that don't support "non-consecutive IDs". But that's the same for any new piece of functionality. The good news it will be obvious to users what their pre-downgrade IDs are - as they'll now be populated fully in the settings. You can even add a warning in the setup that non-consecutive IDs are not supported in version > 2.5.0 (or whatever), whenever non-consecutive IDs are detected...
Prioritisation is entirely your call, and I'm not pushing for it to be added for me. SEDG has committed that they won't change my IDs without telling me again (which might prove difficult as they don't log that change anywhere accessible, even for them! At least they've put a note on my account), so I have consecutive IDs now anyway. I'm waiting to hear back, but they were meeting on Friday with their Tier 1 engineers to discuss how support handles IDs as some wacky advice was being given out and strange actions were taken, which demonstrated that their Tier 3's might not fully understand the Modbus Device ID stuff. Sadly they haven't yet bitten on giving me the holding register number for the new mode - they keep ignoring that question. Not that surprised tbh. As it's a relatively big new feature, I agree that leaving it for a minor version bump is eminently sensible. Thank you for being patient with me, and again, I apologise for any misunderstandings. |
Closing to aggregate into #604 |
Describe the feature
Allow easy access to pymodbus debug logs in HAOS. The documentation notes a 'download diagnostics' option that no longer appears.
Home Assistant (please complete the following information):
Additional context
I am talking to SolarEdge to diagnose issues with multi-inverter site's new home backup functionality - which isn't currently working or supported. (Apparently it's setting parameter 1404 which can be changed from
1
to2
to indicateMulti-Inverter Backup Mode
).However, when they made that change on my system this TCP modbus integration failed. Here is the current logging with debug enabled:
I would like an easy way to enable debug logging on
pymodbus
and download logs so that I can see what communications are occurring to hopefully help SolarEdge diagnose the issue. Obviously they don't officially support Pymodbus or this integration so I would like to provide as much useful information to them to hopefully get this working again.I looked up pymodbus and the debug logs show raw frame data which I feel could be invaluable - i.e. it would be great to show SolarEdge what data is sent on the modbus and to see if there's some kind of unexpected response. Obviously, I'd share the logs here too.
Appreciate your help.