Notifications
You must be signed in to change notification settings - Fork 96
/
dpt_2byte_float.py
295 lines (214 loc) · 6.44 KB
/
dpt_2byte_float.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
"""
Implementation of KNX 2 byte Float-values.
They correspond to the the following KDN DPT 9 class.
"""
from xknx.exceptions import ConversionError
from .dpt import DPTBase
class DPT2ByteFloat(DPTBase):
"""
Abstraction for KNX 2 Octet Floating Point Numbers.
DPT 9.***
"""
value_min = -671088.64
value_max = 670760.96
dpt_main_number = 9
dpt_sub_number = None
value_type = "2byte_float"
unit = ""
resolution = 0.01
payload_length = 2
@classmethod
def from_knx(cls, raw):
"""Parse/deserialize from KNX/IP raw data."""
cls.test_bytesarray(raw)
data = (raw[0] * 256) + raw[1]
exponent = (data >> 11) & 0x0F
significand = data & 0x7FF
sign = data >> 15
if sign == 1:
significand = significand - 2048
value = float(significand << exponent) / 100
if not cls._test_boundaries(value):
raise ConversionError("Could not parse %s" % cls.__name__, value=value)
return value
@classmethod
def to_knx(cls, value):
"""Serialize to KNX/IP raw data."""
def calc_exponent(float_value, sign):
"""Return float exponent."""
exponent = 0
significand = abs(int(float_value * 100))
while significand < -2048 or significand > 2048:
exponent += 1
significand >>= 1
if sign:
significand ^= 0x7FF # invert
significand += 1 # and add 1
return exponent, significand
try:
knx_value = float(value)
if not cls._test_boundaries(knx_value):
raise ValueError
sign = 1 if knx_value < 0 else 0
exponent, significand = calc_exponent(knx_value, sign)
return (sign << 7) | (exponent << 3) | (
significand >> 8
), significand & 0xFF
except ValueError:
raise ConversionError("Could not serialize %s" % cls.__name__, value=value)
@classmethod
def _test_boundaries(cls, value):
"""Test if value is within defined range for this object."""
return cls.value_min <= value <= cls.value_max
class DPTTemperature(DPT2ByteFloat):
"""DPT 9.001 DPT_Value_Temp."""
value_min = -273
value_max = 670760
dpt_main_number = 9
dpt_sub_number = 1
value_type = "temperature"
unit = "°C"
ha_device_class = "temperature"
class DPTTemperatureDifference2Byte(DPT2ByteFloat):
"""DPT 9.002 DPT_Value_Tempd."""
value_min = -670760
value_max = 670760
dpt_main_number = 9
dpt_sub_number = 2
value_type = "temperature_difference_2byte"
unit = "K"
ha_device_class = "temperature"
class DPTTemperatureA(DPT2ByteFloat):
"""DPT 9.003 DPT_Value_Tempa."""
value_min = -670760
value_max = 670760
dpt_main_number = 9
dpt_sub_number = 3
value_type = "temperature_a"
unit = "K/h"
class DPTLux(DPT2ByteFloat):
"""DPT 9.004 DPT_Value_Lux."""
value_min = 0
value_max = 670760
dpt_main_number = 9
dpt_sub_number = 4
value_type = "illuminance"
unit = "lx"
ha_device_class = "illuminance"
class DPTWsp(DPT2ByteFloat):
"""DPT 9.005 DPT_Value_Ws Speed (m/s)."""
value_min = 0
value_max = 670760
dpt_main_number = 9
dpt_sub_number = 5
value_type = "wind_speed_ms"
unit = "m/s"
class DPTPressure2Byte(DPT2ByteFloat):
"""DPT 9.006 DPT_Value_Pres (Pa)."""
value_min = 0
value_max = 670760
dpt_main_number = 9
dpt_sub_number = 6
value_type = "pressure_2byte"
unit = "Pa"
ha_device_class = "pressure"
class DPTHumidity(DPT2ByteFloat):
"""DPT 9.007 DPT_Value_Humidity."""
value_min = 0
value_max = 670760
dpt_main_number = 9
dpt_sub_number = 7
value_type = "humidity"
unit = "%"
ha_device_class = "humidity"
class DPTPartsPerMillion(DPT2ByteFloat):
"""DPT 9.008 DPT_Value_parts/million."""
dpt_main_number = 9
dpt_sub_number = 8
value_type = "ppm"
unit = "ppm"
class DPTTime1(DPT2ByteFloat):
"""DPT 9.010 DPT_Value_Time1 (s)."""
value_min = -670760
value_max = 670760
dpt_main_number = 9
dpt_sub_number = 10
value_type = "time_1"
unit = "s"
class DPTTime2(DPT2ByteFloat):
"""DPT 9.011 DPT_Value_Time2 (ms)."""
value_min = -670760
value_max = 670760
dpt_main_number = 9
dpt_sub_number = 11
value_type = "time_2"
unit = "ms"
class DPTVoltage(DPT2ByteFloat):
"""DPT 9.020 DPT_Value_Voltage."""
dpt_main_number = 9
dpt_sub_number = 20
value_type = "voltage"
unit = "mV"
class DPTCurrent(DPT2ByteFloat):
"""DPT 9.021 DPT_Value_Curr (mA)."""
dpt_main_number = 9
dpt_sub_number = 21
value_type = "curr"
unit = "mA"
class DPTPowerDensity(DPT2ByteFloat):
"""DPT 9.022 DPT_PowerDensity (W/m²)."""
dpt_main_number = 9
dpt_sub_number = 22
value_type = "power_density"
unit = "W/m²"
class DPTKelvinPerPercent(DPT2ByteFloat):
"""DPT 9.023 DPT_KelvinPerPercent (K/%)."""
dpt_main_number = 9
dpt_sub_number = 23
value_type = "kelvin_per_percent"
unit = "K/%"
class DPTPower2Byte(DPT2ByteFloat):
"""DPT 9.024 DPT_Power (kW)."""
dpt_main_number = 9
dpt_sub_number = 24
value_type = "power_2byte"
unit = "kW"
ha_device_class = "power"
class DPTVolumeFlow(DPT2ByteFloat):
"""DPT 9.025 DPT_Value_Volume_Flow (l/h)."""
dpt_main_number = 9
dpt_sub_number = 25
value_type = "volume_flow"
unit = "l/h"
class DPTRainAmount(DPT2ByteFloat):
"""DPT 9.026 DPT_Rain_Amount (l/m²)."""
value_min = -671088.64
value_max = 670760.96
dpt_main_number = 9
dpt_sub_number = 26
value_type = "rain_amount"
unit = "l/m²"
class DPTTemperatureF(DPT2ByteFloat):
"""DPT 9.027 DPT_Value_Temp_F."""
value_min = -459.6
value_max = 670760
dpt_main_number = 9
dpt_sub_number = 27
value_type = "temperature_f"
unit = "°F"
ha_device_class = "temperature"
class DPTWspKmh(DPT2ByteFloat):
"""DPT 9.028 DPT_Value_Wsp_kmh Speed (km/h)."""
value_min = 0
value_max = 670760
dpt_main_number = 9
dpt_sub_number = 28
value_type = "wind_speed_kmh"
unit = "km/h"
class DPTEnthalpy(DPT2ByteFloat):
"""DPT 9.* 2-byte float value (with unit)."""
dpt_main_number = 9
# this is here for backwards compatibility
dpt_sub_number = 999
value_type = "enthalpy"
unit = "H"