Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Change backup Frequency in config-panel is not applied #119

Open
xoddark opened this issue Jan 18, 2022 · 2 comments
Open

Change backup Frequency in config-panel is not applied #119

xoddark opened this issue Jan 18, 2022 · 2 comments

Comments

@xoddark
Copy link

xoddark commented Jan 18, 2022

Describe the bug

When change of the backup Frequency (OnCalendar) in config-panel, the change is not applied to system.

Context

  • Hardware: Dedicated server ...
  • YunoHost version: 4.3.6
  • I have access to my server: Through SSH | through the webadmin
  • Are you in a special context or did you perform some particular tweaking on your YunoHost instance?: no
  • Using, or trying to install package version/branch: borg 1.1.16~ynh28

Steps to reproduce

  • Installing borg with :
  • with just ynh conf backup (enough to test)
  • backup every fifteen minutes (for example) / set Frequency to : *:0/15
  • Always mail (to know when backup is finished)
  • Wait and see than a backup is done every hours
  • Change borg backup Frequency to Daily
    1. Go to 'app borg' option
    2. Click on 'Config Panel' button
    3. Change Frequency to 'Frequency'
    4. Click on save
  • Observe than backup is always done every fifteen minutes

And If you launch the command systemctl stop borg.timer on server, you have this message :
Warning: The unit file, source configuration file or drop-ins of borg.timer changed on disk. Run 'systemctl daemon-reload' to reload units.

Expected behavior

When change in config-panel is saved, we expect than the change was applied.
Yunohost should probably run the command (or equivalent) :
systemctl daemon-reload

@olberger
Copy link

olberger commented May 3, 2022

Just to add my +1
Before:

# systemctl status borg.timer
Warning: The unit file, source configuration file or drop-ins of borg.timer changed on disk. Run 'systemctl daemon-reload' to reload units.
● borg.timer - Run backup borg regularly
     Loaded: loaded (/etc/systemd/system/borg.timer; enabled; vendor preset: enabled)
     Active: active (waiting) since Tue 2022-05-03 14:23:26 CEST; 24min ago
    Trigger: Wed 2022-05-04 00:00:00 CEST; 9h left
   Triggers: ● borg.service

May 03 14:23:26 ynh.cgt-imt.org systemd[1]: Started Run backup borg regularly.

After:

root@ynh:~# systemctl daemon-reload
root@ynh:~# systemctl status borg.timer
● borg.timer - Run backup borg regularly
     Loaded: loaded (/etc/systemd/system/borg.timer; enabled; vendor preset: enabled)
     Active: active (waiting) since Tue 2022-05-03 14:23:26 CEST; 24min ago
    Trigger: Tue 2022-05-03 15:00:00 CEST; 11min left
   Triggers: ● borg.service

May 03 14:23:26 ynh.cgt-imt.org systemd[1]: Started Run backup borg regularly.

@rochacbruno
Copy link

+1 I just had this same issue, adding daemon-reload and restart borg.timer worked for me.

Can we adjust it on the package somewhere?

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment