Hi,
i use multiple humidity sensors all with according adafruit libraries. Obviously HTU21D gives odd values sometimes up to 110%. This graphs shows the values without additional computing.
htu21d

@microbuilder
Copy link
Contributor

This may have been cause by the lack of forcing floats when converting values, and not clearing status bits, both of which are addressed in 0042e4e ... closing this, but if it's still an issue feel free to reopen and we'll dig further into it. Thanks!