Ansys Lumerical 2022 R2.3 Variational FDTD Solver Version 7.20.3191 (Windows 64bit)
expires (month/day/year): Permanent
using config file: Ansys Licensing set with ANSYSLMD_LICENSE_FILE
license host: 1055@132.64.56.90
current time: Mon Nov 21 11:30:02 2022
Running on host: labnum11
All processes are communicating and ready to proceed to simulation...
Running lms file: C:\Program Files\Lumerical\v222\bin\varfdtd-engine.exe -t 32 -remote G:/My Drive/matlab_prog/LumericalAPI/Example.lms
Starting meshing
Simulation size in gridpoints: 1 x 44 x 1
Refined 0 mesh cells (0%)
Completed meshing!
Meshing complete in 0 seconds of CPU time
Starting meshing
Simulation size in gridpoints: 1 x 44 x 1
Refined 0 mesh cells (0%)
Completed meshing!
Meshing complete in 0 seconds of CPU time
Starting meshing
Simulation size in gridpoints: 1 x 44 x 1
Refined 0 mesh cells (0%)
Completed meshing!
Meshing complete in 0 seconds of CPU time
number of processors is 16
processors are distributed as: 8x2x1
Running TE Simulation
Starting meshing
Simulation size in gridpoints: 32 x 54 x 1
Refined 0 mesh cells (0%)
Completed meshing!
Meshing complete in 0 seconds of CPU time
0 0
Starting meshing
Simulation size in gridpoints: 32 x 54 x 1
Refined 0 mesh cells (0%)
Completed meshing!
Meshing complete in 0 seconds of CPU time
0 0
finished material properties
Selected kernel with optimization level: 0 and split-field propagation direction: 0
-----------------------------------------
Beginning initialization of TE Simulation
Starting to add sources to simulation
Adding TE Mode Source propagating in X
Starting to add boundary conditions to simulation
Adding TE PML BC
Adding TE parallel BC
Adding TE PML BC
Adding TE parallel BC
Starting to add monitors to Simulation
Adding analysis monitor
Adding TE DFT monitor
Adding TE DFT monitor
Finished initialization of TE Simulation
-----------------------------------------
All processes are communicating and ready to proceed to simulation...
Starting 1352 total iterations
4% complete. Max time remaining: 1 secs. Auto Shutoff: 1
8% complete. Max time remaining: 1 secs. Auto Shutoff: 1
18% complete. Max time remaining: 1 secs. Auto Shutoff: 1
37% complete. Max time remaining: 1 secs. Auto Shutoff: 1
75% complete. Max time remaining: 0 secs. Auto Shutoff: 1
100% complete. Max time remaining: 0 secs. Auto Shutoff: 1
Completed 1352 iterations, or 1.33474e-13s of Simulation Time
Process 0 starting to collect data
collecting monitor data
collecting source data
Finished collecting data
1728
1352
0.867547
Simulation completed successfully at: Mon Nov 21 11:30:04 2022
Overall wall time measurements in seconds: 3.75523
time to mesh and initialize: 0.011863
time to run FDTD simulation: 0.867547
time to finalize data and save to files: 0.0376497
miscellaneous time: 2.83814
FDTD solver speed on process 0: 2.69295 Mnodes/s
total FDTD solver speed on 16 processes: 43.0871 Mnodes/s