main.go
136 lines (119 loc) · 3.03 KB
/
main.go
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
package main
import (
"fmt"
"log"
"os"
"os/signal"
"syscall"
"time"
"github.com/allefr/go-sensors/env"
"github.com/allefr/go-sensors/env/hihxxxx_021"
"github.com/allefr/go-sensors/env/mcp9808"
"github.com/allefr/go-sensors/env/shtc3"
"periph.io/x/periph/conn/i2c"
"periph.io/x/periph/conn/i2c/i2creg"
"periph.io/x/periph/host"
)
const interval = 5 // [sec]
const (
thermalTestDevice = false
thermalTestChamber = true
)
func main() {
// Make sure periph is initialized.
if _, err := host.Init(); err != nil {
log.Fatal(err)
}
// open i2c bus
bus, err := i2creg.Open("/dev/i2c-1")
if err != nil {
log.Fatalf("failed to open I2C: %v", err)
}
defer bus.Close()
setupCloseHandler(bus)
var t1, t2, t3, t4 env.TempDriver
var h1, h2 env.HumDriver
if thermalTestDevice {
// mcp9808
t1, err = mcp9808.New(mcp9808.Params{Bus: bus, Addr: 0x18, Name: "bread-board"})
if err != nil {
log.Fatalf("%s: %v\n", t1.String(), err)
}
t2, err = mcp9808.New(mcp9808.Params{Bus: bus, Addr: 0x19, Name: "back-bone-plate"})
if err != nil {
log.Fatalf("%s: %v\n", t2.String(), err)
}
t3, err = mcp9808.New(mcp9808.Params{Bus: bus, Addr: 0x1b, Name: "beacon"})
if err != nil {
log.Fatalf("%s: %v\n", t3.String(), err)
}
t4, err = mcp9808.New(mcp9808.Params{Bus: bus, Addr: 0x1e, Name: "I/O-chamber"})
if err != nil {
log.Fatalf("%s: %v\n", t4.String(), err)
}
// hih6030
h1, err = hihxxxx_021.New(hihxxxx_021.Params{Bus: bus, Name: "EDFA-back"})
if err != nil {
log.Fatalf("%s: %v\n", h1.String(), err)
}
}
if thermalTestChamber {
// shtc3
h2, err = shtc3.New(shtc3.Params{Bus: bus, Name: "chamber"})
if err != nil {
log.Fatalf("%s: %v\n", h2.String(), err)
}
}
var tStart time.Time
// start infinite loop to query data
for {
tStart = time.Now()
if thermalTestDevice {
if str, err := t1.StringJSON(); err != nil {
// fmt.Printf("%s: %v\n", t1.String(), err)
} else {
fmt.Println(str)
}
if str, err := t2.StringJSON(); err != nil {
// fmt.Printf("%s: %v\n", t2.String(), err)
} else {
fmt.Println(str)
}
if str, err := t3.StringJSON(); err != nil {
// fmt.Printf("%s: %v\n", t3.String(), err)
} else {
fmt.Println(str)
}
if str, err := t4.StringJSON(); err != nil {
// fmt.Printf("%s: %v\n", t4.String(), err)
} else {
fmt.Println(str)
}
if str, err := h1.StringJSON(); err != nil {
// fmt.Printf("%s: %v\n", h1.String(), err)
} else {
fmt.Println(str)
}
}
if thermalTestChamber {
if str, err := h2.StringJSON(); err != nil {
fmt.Printf("%s: %v\n", h2.String(), err)
} else {
fmt.Println(str)
}
}
// repeat exactly every interval sec
time.Sleep(interval*time.Second - time.Since(tStart))
}
}
// make sure i2c bus gets closed even if system stops application
func setupCloseHandler(bus i2c.BusCloser) {
c := make(chan os.Signal)
signal.Notify(c, os.Interrupt, syscall.SIGTERM)
go func(b i2c.BusCloser) {
<-c
fmt.Println("\r- Ctrl+C pressed in Terminal")
b.Close()
os.Exit(0)
}(bus)
}