Notifications
You must be signed in to change notification settings - Fork 0
/
dbus_generator.py
executable file
·920 lines (796 loc) · 36.2 KB
/
dbus_generator.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
#!/usr/bin/python -u
# -*- coding: utf-8 -*-
# Function
# dbus_generator monitors the dbus for batteries (com.victronenergy.battery.*) and
# vebus com.victronenergy.vebus.*
# Battery and vebus monitors can be configured through the gui.
# It then monitors SOC, AC loads, battery current and battery voltage,to auto start/stop the generator based
# on the configuration settings. Generator can be started manually or periodically setting a tes trun period.
# Time zones function allows to use different values for the conditions along the day depending on time
from dbus.mainloop.glib import DBusGMainLoop
import gobject
import dbus
import dbus.service
import datetime
import calendar
import platform
import argparse
import time
import sys
import json
import os
from os import environ
# Victron packages
sys.path.insert(1, os.path.join(os.path.dirname(__file__), './ext/velib_python'))
from vedbus import VeDbusService
from vedbus import VeDbusItemImport
from ve_utils import exit_on_error
from dbusmonitor import DbusMonitor
from settingsdevice import SettingsDevice
from logger import setup_logging
softwareversion = '1.2.9'
dbusgenerator = None
class DbusGenerator:
def __init__(self, retries=300):
self._bus = dbus.SystemBus() if (platform.machine() == 'armv7l' or 'DBUS_SESSION_BUS_ADDRESS' not in environ) else dbus.SessionBus()
self.RELAY_GPIO_FILE = '/sys/class/gpio/gpio182/value'
self.HISTORY_DAYS = 30
# One second per retry
self.RETRIES_ON_ERROR = retries
self._testrun_soc_retries = 0
self._last_counters_check = 0
self._dbusservice = None
self._starttime = 0
self._manualstarttimer = 0
self._last_runtime_update = 0
self._timer_runnning = 0
self._battery_measurement_voltage_import = None
self._battery_measurement_current_import = None
self._battery_measurement_soc_import = None
self._battery_measurement_available = True
self._vebusservice_high_temperature_import = None
self._vebusservice_overload_import = None
self._vebusservice = None
self._vebusservice_available = False
self._relay_state_import = None
self._condition_stack = {
'batteryvoltage': {
'name': 'batteryvoltage',
'reached': False,
'boolean': False,
'timed': True,
'start_timer': 0,
'stop_timer': 0,
'valid': True,
'enabled': False,
'retries': 0,
'monitoring': 'battery'
},
'batterycurrent': {
'name': 'batterycurrent',
'reached': False,
'boolean': False,
'timed': True,
'start_timer': 0,
'stop_timer': 0,
'valid': True,
'enabled': False,
'retries': 0,
'monitoring': 'battery'
},
'acload': {
'name': 'acload',
'reached': False,
'boolean': False,
'timed': True,
'start_timer': 0,
'stop_timer': 0,
'valid': True,
'enabled': False,
'retries': 0,
'monitoring': 'vebus'
},
'inverterhightemp': {
'name': 'inverterhightemp',
'reached': False,
'boolean': True,
'timed': True,
'start_timer': 0,
'stop_timer': 0,
'valid': True,
'enabled': False,
'retries': 0,
'monitoring': 'vebus'
},
'inverteroverload': {
'name': 'inverteroverload',
'reached': False,
'boolean': True,
'timed': True,
'start_timer': 0,
'stop_timer': 0,
'valid': True,
'enabled': False,
'retries': 0,
'monitoring': 'vebus'
},
'soc': {
'name': 'soc',
'reached': False,
'boolean': False,
'timed': False,
'valid': True,
'enabled': False,
'retries': 0,
'monitoring': 'battery'
}
}
# DbusMonitor expects these values to be there, even though we don need them. So just
# add some dummy data. This can go away when DbusMonitor is more generic.
dummy = {'code': None, 'whenToLog': 'configChange', 'accessLevel': None}
# TODO: possible improvement: don't use the DbusMonitor it all, since we are only monitoring
# a set of static values which will always be available. DbusMonitor watches for services
# that come and go, and takes care of automatic signal subscribtions etc. etc: all not necessary
# in this use case where we have fixed services names (com.victronenergy.settings, and c
# com.victronenergy.system).
self._dbusmonitor = DbusMonitor({
'com.victronenergy.settings': { # This is not our setting so do it here. not in supportedSettings
'/Settings/Relay/Function': dummy,
'/Settings/Relay/Polarity': dummy,
'/Settings/System/TimeZone': dummy,
},
'com.victronenergy.system': { # This is not our setting so do it here. not in supportedSettings
'/Ac/Consumption/Total/Power': dummy,
'/Ac/PvOnOutput/Total/Power': dummy,
'/Ac/PvOnGrid/Total/Power': dummy,
'/Ac/PvOnGenset/Total/Power': dummy,
'/Dc/Pv/Power': dummy,
'/AutoSelectedBatteryMeasurement': dummy,
}
}, self._dbus_value_changed, self._device_added, self._device_removed)
# Set timezone to user selected timezone
environ['TZ'] = self._dbusmonitor.get_value('com.victronenergy.settings', '/Settings/System/TimeZone')
# Connect to localsettings
self._settings = SettingsDevice(
bus=self._bus,
supportedSettings={
'autostart': ['/Settings/Generator0/AutoStartEnabled', 1, 0, 1],
'accumulateddaily': ['/Settings/Generator0/AccumulatedDaily', '', 0, 0],
'accumulatedtotal': ['/Settings/Generator0/AccumulatedTotal', 0, 0, 0],
'batterymeasurement': ['/Settings/Generator0/BatteryService', "default", 0, 0],
'minimumruntime': ['/Settings/Generator0/MinimumRuntime', 0, 0, 86400], # minutes
# On permanent loss of communication: 0 = Stop, 1 = Start, 2 = keep running
'onlosscommunication': ['/Settings/Generator0/OnLossCommunication', 0, 0, 2],
# Quiet hours
'quiethoursenabled': ['/Settings/Generator0/QuietHours/Enabled', 0, 0, 1],
'quiethoursstarttime': ['/Settings/Generator0/QuietHours/StartTime', 75600, 0, 86400],
'quiethoursendtime': ['/Settings/Generator0/QuietHours/EndTime', 21600, 0, 86400],
# SOC
'socenabled': ['/Settings/Generator0/Soc/Enabled', 0, 0, 1],
'socstart': ['/Settings/Generator0/Soc/StartValue', 90, 0, 100],
'socstop': ['/Settings/Generator0/Soc/StopValue', 90, 0, 100],
'qh_socstart': ['/Settings/Generator0/Soc/QuietHoursStartValue', 90, 0, 100],
'qh_socstop': ['/Settings/Generator0/Soc/QuietHoursStopValue', 90, 0, 100],
# Voltage
'batteryvoltageenabled': ['/Settings/Generator0/BatteryVoltage/Enabled', 0, 0, 1],
'batteryvoltagestart': ['/Settings/Generator0/BatteryVoltage/StartValue', 11.5, 0, 150],
'batteryvoltagestop': ['/Settings/Generator0/BatteryVoltage/StopValue', 12.4, 0, 150],
'batteryvoltagestarttimer': ['/Settings/Generator0/BatteryVoltage/StartTimer', 20, 0, 10000],
'batteryvoltagestoptimer': ['/Settings/Generator0/BatteryVoltage/StopTimer', 20, 0, 10000],
'qh_batteryvoltagestart': ['/Settings/Generator0/BatteryVoltage/QuietHoursStartValue', 11.9, 0, 100],
'qh_batteryvoltagestop': ['/Settings/Generator0/BatteryVoltage/QuietHoursStopValue', 12.4, 0, 100],
# Current
'batterycurrentenabled': ['/Settings/Generator0/BatteryCurrent/Enabled', 0, 0, 1],
'batterycurrentstart': ['/Settings/Generator0/BatteryCurrent/StartValue', 10.5, 0.5, 1000],
'batterycurrentstop': ['/Settings/Generator0/BatteryCurrent/StopValue', 5.5, 0, 1000],
'batterycurrentstarttimer': ['/Settings/Generator0/BatteryCurrent/StartTimer', 20, 0, 10000],
'batterycurrentstoptimer': ['/Settings/Generator0/BatteryCurrent/StopTimer', 20, 0, 10000],
'qh_batterycurrentstart': ['/Settings/Generator0/BatteryCurrent/QuietHoursStartValue', 20.5, 0, 1000],
'qh_batterycurrentstop': ['/Settings/Generator0/BatteryCurrent/QuietHoursStopValue', 15.5, 0, 1000],
# AC load
'acloadenabled': ['/Settings/Generator0/AcLoad/Enabled', 0, 0, 1],
'acloadstart': ['/Settings/Generator0/AcLoad/StartValue', 1600, 5, 100000],
'acloadstop': ['/Settings/Generator0/AcLoad/StopValue', 800, 0, 100000],
'acloadstarttimer': ['/Settings/Generator0/AcLoad/StartTimer', 20, 0, 10000],
'acloadstoptimer': ['/Settings/Generator0/AcLoad/StopTimer', 20, 0, 10000],
'qh_acloadstart': ['/Settings/Generator0/AcLoad/QuietHoursStartValue', 1900, 0, 100000],
'qh_acloadstop': ['/Settings/Generator0/AcLoad/QuietHoursStopValue', 1200, 0, 100000],
# VE.Bus high temperature
'inverterhightempenabled': ['/Settings/Generator0/InverterHighTemp/Enabled', 0, 0, 1],
'inverterhightempstarttimer': ['/Settings/Generator0/InverterHighTemp/StartTimer', 20, 0, 10000],
'inverterhightempstoptimer': ['/Settings/Generator0/InverterHighTemp/StopTimer', 20, 0, 10000],
# VE.Bus overload
'inverteroverloadenabled': ['/Settings/Generator0/InverterOverload/Enabled', 0, 0, 1],
'inverteroverloadstarttimer': ['/Settings/Generator0/InverterOverload/StartTimer', 20, 0, 10000],
'inverteroverloadstoptimer': ['/Settings/Generator0/InverterOverload/StopTimer', 20, 0, 10000],
# TestRun
'testrunenabled': ['/Settings/Generator0/TestRun/Enabled', 0, 0, 1],
'testrunstartdate': ['/Settings/Generator0/TestRun/StartDate', time.time(), 0, 10000000000.1],
'testrunstarttimer': ['/Settings/Generator0/TestRun/StartTime', 54000, 0, 86400],
'testruninterval': ['/Settings/Generator0/TestRun/Interval', 28, 1, 365],
'testrunruntime': ['/Settings/Generator0/TestRun/Duration', 7200, 1, 86400],
'testrunskipruntime': ['/Settings/Generator0/TestRun/SkipRuntime', 0, 0, 100000],
'testruntillbatteryfull': ['/Settings/Generator0/TestRun/RunTillBatteryFull', 0, 0, 1]
},
eventCallback=self._handle_changed_setting)
# Whenever services come or go, we need to check if it was a service we use. Note that this
# is a bit double: DbusMonitor does the same thing. But since we don't use DbusMonitor to
# monitor for com.victronenergy.battery, .vebus, .charger or any other possible source of
# battery data, it is necessary to monitor for changes in the available dbus services.
self._bus.add_signal_receiver(self._dbus_name_owner_changed, signal_name='NameOwnerChanged')
self._evaluate_if_we_are_needed()
gobject.timeout_add(1000, self._handletimertick)
self._update_relay()
self._changed = True
def _evaluate_if_we_are_needed(self):
if self._dbusmonitor.get_value('com.victronenergy.settings', '/Settings/Relay/Function') == 1:
if not self._relay_state_import:
logger.info('Getting relay from systemcalc.')
try:
self._relay_state_import = VeDbusItemImport(
bus=self._bus, serviceName='com.victronenergy.system',
path='/Relay/0/State',
eventCallback=None, createsignal=True)
except dbus.exceptions.DBusException:
logger.info('Systemcalc relay not available.')
self._relay_state_import = None
pass
if self._dbusservice is None:
logger.info('Action! Going on dbus and taking control of the relay.')
relay_polarity_import = VeDbusItemImport(
bus=self._bus, serviceName='com.victronenergy.settings',
path='/Settings/Relay/Polarity',
eventCallback=None, createsignal=True)
# As is not possible to keep the relay state during the CCGX power cycles,
# set the relay polarity to normally open.
if relay_polarity_import.get_value() == 1:
relay_polarity_import.set_value(0)
logger.info('Setting relay polarity to normally open.')
# put ourselves on the dbus
self._dbusservice = VeDbusService('com.victronenergy.generator.startstop0')
self._dbusservice.add_mandatory_paths(
processname=__file__,
processversion=softwareversion,
connection='generator',
deviceinstance=0,
productid=None,
productname=None,
firmwareversion=None,
hardwareversion=None,
connected=1)
# State: None = invalid, 0 = stopped, 1 = running
self._dbusservice.add_path('/State', value=0)
# Condition that made the generator start
self._dbusservice.add_path('/RunningByCondition', value='')
# Runtime
self._dbusservice.add_path('/Runtime', value=0, gettextcallback=self._gettext)
# Today runtime
self._dbusservice.add_path('/TodayRuntime', value=0, gettextcallback=self._gettext)
# Test run runtime
self._dbusservice.add_path('/TestRunIntervalRuntime',
value=self._interval_runtime(self._settings['testruninterval']),
gettextcallback=self._gettext)
# Next tes trun date, values is 0 for test run disabled
self._dbusservice.add_path('/NextTestRun', value=None, gettextcallback=self._gettext)
# Next tes trun is needed 1, not needed 0
self._dbusservice.add_path('/SkipTestRun', value=None)
# Manual start
self._dbusservice.add_path('/ManualStart', value=0, writeable=True)
# Manual start timer
self._dbusservice.add_path('/ManualStartTimer', value=0, writeable=True)
# Silent mode active
self._dbusservice.add_path('/QuietHours', value=0)
self._determineservices()
else:
if self._dbusservice is not None:
self._stop_generator()
self._dbusservice.__del__()
self._dbusservice = None
# Reset conditions
for condition in self._condition_stack:
self._reset_condition(self._condition_stack[condition])
logger.info('Relay function is no longer set to generator start/stop: made sure generator is off ' +
'and now going off dbus')
self._relay_state_import = None
def _device_added(self, dbusservicename, instance):
self._evaluate_if_we_are_needed()
self._determineservices()
def _device_removed(self, dbusservicename, instance):
self._evaluate_if_we_are_needed()
# Relay handling depends on systemcalc, if the service disappears restart
# the relay state import
if dbusservicename == "com.victronenergy.system":
self._relay_state_import = None
self._determineservices()
def _dbus_value_changed(self, dbusServiceName, dbusPath, options, changes, deviceInstance):
if dbusPath == '/AutoSelectedBatteryMeasurement' and self._settings['batterymeasurement'] == 'default':
self._determineservices()
if dbusPath == '/Settings/Relay/Function':
self._evaluate_if_we_are_needed()
self._changed = True
# Update relay state when polarity is changed
if dbusPath == '/Settings/Relay/Polarity':
self._update_relay()
def _handle_changed_setting(self, setting, oldvalue, newvalue):
self._changed = True
self._evaluate_if_we_are_needed()
if setting == 'batterymeasurement':
self._determineservices()
# Reset retries and valid if service changes
for condition in self._condition_stack:
if self._condition_stack[condition]['monitoring'] == 'battery':
self._condition_stack[condition]['valid'] = True
self._condition_stack[condition]['retries'] = 0
if setting == 'autostart':
logger.info('Autostart function %s.' % ('enabled' if newvalue == 1 else 'disabled'))
if self._dbusservice is not None and setting == 'testruninterval':
self._dbusservice['/TestRunIntervalRuntime'] = self._interval_runtime(
self._settings['testruninterval'])
def _dbus_name_owner_changed(self, name, oldowner, newowner):
self._determineservices()
def _gettext(self, path, value):
if path == '/NextTestRun':
# Locale format date
d = datetime.datetime.fromtimestamp(value)
return d.strftime('%c')
elif path in ['/Runtime', '/TestRunIntervalRuntime', '/TodayRuntime']:
m, s = divmod(value, 60)
h, m = divmod(m, 60)
return '%dh, %dm, %ds' % (h, m, s)
else:
return value
def _handletimertick(self):
# try catch, to make sure that we kill ourselves on an error. Without this try-catch, there would
# be an error written to stdout, and then the timer would not be restarted, resulting in a dead-
# lock waiting for manual intervention -> not good!
try:
if self._dbusservice is not None:
self._evaluate_startstop_conditions()
self._changed = False
except:
self._stop_generator()
import traceback
traceback.print_exc()
sys.exit(1)
return True
def _evaluate_startstop_conditions(self):
# Conditions will be evaluated in this order
conditions = ['soc', 'acload', 'batterycurrent', 'batteryvoltage', 'inverterhightemp', 'inverteroverload']
start = False
runningbycondition = None
today = calendar.timegm(datetime.date.today().timetuple())
self._timer_runnning = False
values = self._get_updated_values()
connection_lost = False
self._check_quiet_hours()
# New day, register it
if self._last_counters_check < today and self._dbusservice['/State'] == 0:
self._last_counters_check = today
self._update_accumulated_time()
# Update current and accumulated runtime.
if self._dbusservice['/State'] == 1:
self._dbusservice['/Runtime'] = int(time.time() - self._starttime)
# By performance reasons, accumulated runtime is only updated
# once per 10s. When the generator stops is also updated.
if self._dbusservice['/Runtime'] - self._last_runtime_update >= 10:
self._update_accumulated_time()
if self._evaluate_manual_start():
runningbycondition = 'manual'
start = True
# Autostart conditions will only be evaluated if the autostart functionality is enabled
if self._settings['autostart'] == 1:
if self._evaluate_testrun_condition():
runningbycondition = 'testrun'
start = True
# Evaluate value conditions
for condition in conditions:
start = self._evaluate_condition(self._condition_stack[condition], values[condition]) or start
runningbycondition = condition if start and runningbycondition is None else runningbycondition
# Connection lost is set to true if the numbear of retries of one or more enabled conditions
# >= RETRIES_ON_ERROR
if self._condition_stack[condition]['enabled']:
connection_lost = self._condition_stack[condition]['retries'] >= self.RETRIES_ON_ERROR
# If none condition is reached check if connection is lost and start/keep running the generator
# depending on '/OnLossCommunication' setting
if not start and connection_lost:
# Start always
if self._settings['onlosscommunication'] == 1:
start = True
runningbycondition = 'lossofcommunication'
# Keep running if generator already started
if self._dbusservice['/State'] == 1 and self._settings['onlosscommunication'] == 2:
start = True
runningbycondition = 'lossofcommunication'
if start:
self._start_generator(runningbycondition)
elif (self._dbusservice['/Runtime'] >= self._settings['minimumruntime'] * 60
or self._dbusservice['/RunningByCondition'] == 'manual'):
self._stop_generator()
def _reset_condition(self, condition):
condition['reached'] = False
if condition['timed']:
condition['start_timer'] = 0
condition['stop_timer'] = 0
def _check_condition(self, condition, value):
name = condition['name']
if self._settings[name + 'enabled'] == 0:
if condition['enabled']:
condition['enabled'] = False
logger.info('Disabling (%s) condition' % name)
condition['retries'] = 0
condition['valid'] = True
self._reset_condition(condition)
return False
elif not condition['enabled']:
condition['enabled'] = True
logger.info('Enabling (%s) condition' % name)
if (condition['monitoring'] == 'battery') and (self._settings['batterymeasurement'] == 'nobattery'):
return False
if value is None and condition['valid']:
if condition['retries'] >= self.RETRIES_ON_ERROR:
logger.info('Error getting (%s) value, skipping evaluation till get a valid value' % name)
self._reset_condition(condition)
self._comunnication_lost = True
condition['valid'] = False
else:
condition['retries'] += 1
if condition['retries'] == 1 or (condition['retries'] % 10) == 0:
logger.info('Error getting (%s) value, retrying(#%i)' % (name, condition['retries']))
return False
elif value is not None and not condition['valid']:
logger.info('Success getting (%s) value, resuming evaluation' % name)
condition['valid'] = True
condition['retries'] = 0
# Reset retries if value is valid
if value is not None:
condition['retries'] = 0
return condition['valid']
def _evaluate_condition(self, condition, value):
name = condition['name']
setting = ('qh_' if self._dbusservice['/QuietHours'] == 1 else '') + name
startvalue = self._settings[setting + 'start'] if not condition['boolean'] else 1
stopvalue = self._settings[setting + 'stop'] if not condition['boolean'] else 0
# Check if the condition has to be evaluated
if not self._check_condition(condition, value):
# If generator is started by this condition and value is invalid
# wait till RETRIES_ON_ERROR to skip the condition
if condition['reached'] and condition['retries'] <= self.RETRIES_ON_ERROR:
return True
return False
# As this is a generic evaluation method, we need to know how to compare the values
# first check if start value should be greater than stop value and then compare
start_is_greater = startvalue > stopvalue
# When the condition is already reached only the stop value can set it to False
start = condition['reached'] or (value >= startvalue if start_is_greater else value <= startvalue)
stop = value <= stopvalue if start_is_greater else value >= stopvalue
# Timed conditions must start/stop after the condition has been reached for a minimum
# time.
if condition['timed']:
if not condition['reached'] and start:
condition['start_timer'] += time.time() if condition['start_timer'] == 0 else 0
start = time.time() - condition['start_timer'] >= self._settings[name + 'starttimer']
condition['stop_timer'] *= int(not start)
self._timer_runnning = True
else:
condition['start_timer'] = 0
if condition['reached'] and stop:
condition['stop_timer'] += time.time() if condition['stop_timer'] == 0 else 0
stop = time.time() - condition['stop_timer'] >= self._settings[name + 'stoptimer']
condition['stop_timer'] *= int(not stop)
self._timer_runnning = True
else:
condition['stop_timer'] = 0
condition['reached'] = start and not stop
return condition['reached']
def _evaluate_manual_start(self):
if self._dbusservice['/ManualStart'] == 0:
if self._dbusservice['/RunningByCondition'] == 'manual':
self._dbusservice['/ManualStartTimer'] = 0
return False
start = True
# If /ManualStartTimer has a value greater than zero will use it to set a stop timer.
# If no timer is set, the generator will not stop until the user stops it manually.
# Once started by manual start, each evaluation the timer is decreased
if self._dbusservice['/ManualStartTimer'] != 0:
self._manualstarttimer += time.time() if self._manualstarttimer == 0 else 0
self._dbusservice['/ManualStartTimer'] -= int(time.time()) - int(self._manualstarttimer)
self._manualstarttimer = time.time()
start = self._dbusservice['/ManualStartTimer'] > 0
self._dbusservice['/ManualStart'] = int(start)
# Reset if timer is finished
self._manualstarttimer *= int(start)
self._dbusservice['/ManualStartTimer'] *= int(start)
return start
def _evaluate_testrun_condition(self):
if self._settings['testrunenabled'] == 0:
self._dbusservice['/SkipTestRun'] = None
self._dbusservice['/NextTestRun'] = None
return False
today = datetime.date.today()
runtillbatteryfull = self._settings['testruntillbatteryfull'] == 1
soc = self._get_updated_values()['soc']
batteryisfull = runtillbatteryfull and soc == 100
try:
startdate = datetime.date.fromtimestamp(self._settings['testrunstartdate'])
starttime = time.mktime(today.timetuple()) + self._settings['testrunstarttimer']
except ValueError:
logger.debug('Invalid dates, skipping testrun')
return False
# If start date is in the future set as NextTestRun and stop evaluating
if startdate > today:
self._dbusservice['/NextTestRun'] = time.mktime(startdate.timetuple())
return False
start = False
# If the accumulated runtime during the tes trun interval is greater than '/TestRunIntervalRuntime'
# the tes trun must be skipped
needed = (self._settings['testrunskipruntime'] > self._dbusservice['/TestRunIntervalRuntime']
or self._settings['testrunskipruntime'] == 0)
self._dbusservice['/SkipTestRun'] = int(not needed)
interval = self._settings['testruninterval']
stoptime = (starttime + self._settings['testrunruntime']) if not runtillbatteryfull else (starttime + 60)
elapseddays = (today - startdate).days
mod = elapseddays % interval
start = (not bool(mod) and (time.time() >= starttime) and (time.time() <= stoptime))
if runtillbatteryfull:
if soc is not None:
self._testrun_soc_retries = 0
start = (start or self._dbusservice['/RunningByCondition'] == 'testrun') and not batteryisfull
elif self._dbusservice['/RunningByCondition'] == 'testrun':
if self._testrun_soc_retries < self.RETRIES_ON_ERROR:
self._testrun_soc_retries += 1
start = True
if (self._testrun_soc_retries % 10) == 0:
logger.info('Test run failed to get SOC value, retrying(#%i)' % self._testrun_soc_retries)
else:
logger.info('Failed to get SOC after %i retries, terminating test run condition' % self._testrun_soc_retries)
start = False
else:
start = False
if not bool(mod) and (time.time() <= stoptime):
self._dbusservice['/NextTestRun'] = starttime
else:
self._dbusservice['/NextTestRun'] = (time.mktime((today + datetime.timedelta(days=interval - mod)).timetuple()) +
self._settings['testrunstarttimer'])
return start and needed
def _check_quiet_hours(self):
active = False
if self._settings['quiethoursenabled'] == 1:
# Seconds after today 00:00
timeinseconds = time.time() - time.mktime(datetime.date.today().timetuple())
quiethoursstart = self._settings['quiethoursstarttime']
quiethoursend = self._settings['quiethoursendtime']
# Check if the current time is between the start time and end time
if quiethoursstart < quiethoursend:
active = quiethoursstart <= timeinseconds and timeinseconds < quiethoursend
else: # End time is lower than start time, example Start: 21:00, end: 08:00
active = not (quiethoursend < timeinseconds and timeinseconds < quiethoursstart)
if self._dbusservice['/QuietHours'] == 0 and active:
logger.info('Entering to quiet mode')
elif self._dbusservice['/QuietHours'] == 1 and not active:
logger.info('Leaving secondary quiet mode')
self._dbusservice['/QuietHours'] = int(active)
return active
def _update_accumulated_time(self):
seconds = self._dbusservice['/Runtime']
accumulated = seconds - self._last_runtime_update
self._settings['accumulatedtotal'] = int(self._settings['accumulatedtotal']) + accumulated
# Using calendar to get timestamp in UTC, not local time
today_date = str(calendar.timegm(datetime.date.today().timetuple()))
# If something goes wrong getting the json string create a new one
try:
accumulated_days = json.loads(self._settings['accumulateddaily'])
except ValueError:
accumulated_days = {today_date: 0}
if (today_date in accumulated_days):
accumulated_days[today_date] += accumulated
else:
accumulated_days[today_date] = accumulated
self._last_runtime_update = seconds
# Keep the historical with a maximum of HISTORY_DAYS
while len(accumulated_days) > self.HISTORY_DAYS:
accumulated_days.pop(min(accumulated_days.keys()), None)
# Upadate settings
self._settings['accumulateddaily'] = json.dumps(accumulated_days, sort_keys=True)
self._dbusservice['/TodayRuntime'] = self._interval_runtime(0)
self._dbusservice['/TestRunIntervalRuntime'] = self._interval_runtime(self._settings['testruninterval'])
def _interval_runtime(self, days):
summ = 0
try:
daily_record = json.loads(self._settings['accumulateddaily'])
except ValueError:
return 0
for i in range(days + 1):
previous_day = calendar.timegm((datetime.date.today() - datetime.timedelta(days=i)).timetuple())
if str(previous_day) in daily_record.keys():
summ += daily_record[str(previous_day)] if str(previous_day) in daily_record.keys() else 0
return summ
def _get_updated_values(self):
values = {
'batteryvoltage': (self._battery_measurement_voltage_import.get_value()
if self._battery_measurement_voltage_import else None),
'batterycurrent': (self._battery_measurement_current_import.get_value()
if self._battery_measurement_current_import else None),
'soc': self._battery_measurement_soc_import.get_value() if self._battery_measurement_soc_import else None,
'acload': self._dbusmonitor.get_value('com.victronenergy.system', '/Ac/Consumption/Total/Power'),
'inverterhightemp': (self._vebusservice_high_temperature_import.get_value()
if self._vebusservice_high_temperature_import else None),
'inverteroverload': (self._vebusservice_overload_import.get_value()
if self._vebusservice_overload_import else None)
}
if values['batterycurrent']:
values['batterycurrent'] *= -1
return values
def _determineservices(self):
# batterymeasurement is either 'default' or 'com_victronenergy_battery_288/Dc/0'.
# In case it is set to default, we use the AutoSelected battery measurement, given by
# SystemCalc.
batterymeasurement = None
batteryservicename = None
newbatteryservice = None
batteryprefix = ""
selectedbattery = self._settings['batterymeasurement']
vebusservice = None
if selectedbattery == 'default':
batterymeasurement = self._dbusmonitor.get_value('com.victronenergy.system', '/AutoSelectedBatteryMeasurement')
elif len(selectedbattery.split("/", 1)) == 2: # Only very basic sanity checking..
batterymeasurement = self._settings['batterymeasurement']
elif selectedbattery == 'nobattery':
batterymeasurement = None
else:
# Exception: unexpected value for batterymeasurement
pass
if batterymeasurement:
batteryprefix = "/" + batterymeasurement.split("/", 1)[1]
# Get the current battery servicename
if self._battery_measurement_voltage_import:
oldservice = (self._battery_measurement_voltage_import.serviceName +
self._battery_measurement_voltage_import.path.replace("/Voltage", ""))
else:
oldservice = None
if batterymeasurement:
try:
batteryservicename = VeDbusItemImport(
bus=self._bus,
serviceName="com.victronenergy.system",
path='/ServiceMapping/' + batterymeasurement.split("/", 1)[0],
eventCallback=None,
createsignal=False)
if batteryservicename.get_value():
newbatteryservice = batteryservicename.get_value() + batteryprefix
except dbus.exceptions.DBusException:
pass
else:
newbatteryservice = None
if batteryservicename and batteryservicename.get_value():
self._battery_measurement_available = True
logger.info('Battery service we need (%s) found! Using it for generator start/stop'
% batterymeasurement)
try:
self._battery_measurement_voltage_import = VeDbusItemImport(
bus=self._bus, serviceName=batteryservicename.get_value(),
path=batteryprefix + '/Voltage', eventCallback=None, createsignal=True)
self._battery_measurement_current_import = VeDbusItemImport(
bus=self._bus, serviceName=batteryservicename.get_value(),
path=batteryprefix + '/Current', eventCallback=None, createsignal=True)
# Exception caused by Matthijs :), we forgot to batteryprefix the Soc during the big path-change...
self._battery_measurement_soc_import = VeDbusItemImport(
bus=self._bus, serviceName=batteryservicename.get_value(),
path='/Soc', eventCallback=None, createsignal=True)
except Exception:
logger.debug('Error getting battery service!')
self._battery_measurement_voltage_import = None
self._battery_measurement_current_import = None
self._battery_measurement_soc_import = None
elif selectedbattery == 'nobattery' and self._battery_measurement_available:
logger.info('Battery monitoring disabled! Stop evaluating related conditions')
self._battery_measurement_voltage_import = None
self._battery_measurement_current_import = None
self._battery_measurement_soc_import = None
self._battery_measurement_available = False
elif batteryservicename and batteryservicename.get_value() is None and self._battery_measurement_available:
logger.info('Battery service we need (%s) is not available! Stop evaluating related conditions'
% batterymeasurement)
self._battery_measurement_voltage_import = None
self._battery_measurement_current_import = None
self._battery_measurement_soc_import = None
self._battery_measurement_available = False
# Get the default VE.Bus service and import high temperature and overload warnings
try:
vebusservice = VeDbusItemImport(
bus=self._bus,
serviceName="com.victronenergy.system",
path='/VebusService',
eventCallback=None,
createsignal=False)
if vebusservice.get_value() and (vebusservice.get_value() != self._vebusservice
or not self._vebusservice_available):
self._vebusservice = vebusservice.get_value()
self._vebusservice_available = True
logger.info('Vebus service (%s) found! Using it for generator start/stop'
% vebusservice.get_value())
self._vebusservice_high_temperature_import = VeDbusItemImport(
bus=self._bus, serviceName=vebusservice.get_value(),
path='/Alarms/HighTemperature', eventCallback=None, createsignal=True)
self._vebusservice_overload_import = VeDbusItemImport(
bus=self._bus, serviceName=vebusservice.get_value(),
path='/Alarms/Overload', eventCallback=None, createsignal=True)
except Exception:
logger.info('Error getting Vebus service!')
self._vebusservice_available = False
self._vebusservice_high_temperature_import = None
self._vebusservice_overload_import = None
logger.info('Vebus service (%s) dissapeared! Stop evaluating related conditions'
% self._vebusservice)
# Trigger an immediate check of system status
self._changed = True
def _start_generator(self, condition):
if not self._relay_state_import:
logger.info("Relay import not available, can't start generator by %s condition" % condition)
return
systemcalc_relay_state = 0
state = self._dbusservice['/State']
try:
systemcalc_relay_state = self._relay_state_import.get_value()
except dbus.exceptions.DBusException:
logger.info('Error getting relay state')
# This function will start the generator in the case generator not
# already running. When differs, the RunningByCondition is updated
if state == 0 or systemcalc_relay_state != state:
self._dbusservice['/State'] = 1
self._update_relay()
self._starttime = time.time()
logger.info('Starting generator by %s condition' % condition)
elif self._dbusservice['/RunningByCondition'] != condition:
logger.info('Generator previously running by %s condition is now running by %s condition'
% (self._dbusservice['/RunningByCondition'], condition))
self._dbusservice['/RunningByCondition'] = condition
def _stop_generator(self):
if not self._relay_state_import:
logger.info("Relay import not available, can't stop generator")
return
systemcalc_relay_state = 1
state = self._dbusservice['/State']
try:
systemcalc_relay_state = self._relay_state_import.get_value()
except dbus.exceptions.DBusException:
logger.info('Error getting relay state')
if state == 1 or systemcalc_relay_state != state:
self._dbusservice['/State'] = 0
self._update_relay()
logger.info('Stopping generator that was running by %s condition' %
str(self._dbusservice['/RunningByCondition']))
self._dbusservice['/RunningByCondition'] = ''
self._update_accumulated_time()
self._starttime = 0
self._dbusservice['/Runtime'] = 0
self._dbusservice['/ManualStartTimer'] = 0
self._manualstarttimer = 0
self._last_runtime_update = 0
def _update_relay(self):
if not self._relay_state_import:
logger.info("Relay import not available")
return
# Relay polarity 0 = NO, 1 = NC
polarity = bool(self._dbusmonitor.get_value('com.victronenergy.settings', '/Settings/Relay/Polarity'))
w = int(not polarity) if bool(self._dbusservice['/State']) else int(polarity)
try:
self._relay_state_import.set_value(dbus.Int32(w, variant_level=1))
except dbus.exceptions.DBusException:
logger.info('Error setting relay state')
if __name__ == '__main__':
# Argument parsing
parser = argparse.ArgumentParser(
description='Start and stop a generator based on conditions'
)
parser.add_argument('-d', '--debug', help='set logging level to debug',
action='store_true')
parser.add_argument('-r', '--retries', help='Retries on error', default=300, type=int)
args = parser.parse_args()
print '-------- dbus_generator, v' + softwareversion + ' is starting up --------'
logger = setup_logging(args.debug)
# Have a mainloop, so we can send/receive asynchronous calls to and from dbus
DBusGMainLoop(set_as_default=True)
generator = DbusGenerator(args.retries)
# Start and run the mainloop
mainloop = gobject.MainLoop()
mainloop.run()