currently the binding works with
AL_HEATING_DEMAND opd0013 pairing id 333(0x14d)
That works fine for 6 of my 7 RTCs. But at one RTC the value remains always zero. I think this is a Busch Jäger Bug. At this RTC the
AL_HEATING_ACTIVE odp0011 pairing id 331(0x14b) remains always zero too.
I can see this behaviour in this binding, the kjoglums-binding and even at the swagger webinterface.
The speciality of this RTC ist, that it is connected to my second (6-gang heating actuator). The other 6 are connected to the first one.
Nevertheless I want you to ask, to integrate
AL_ACTUATING_VALUE_HEATING opd000 pairing id 48(0x30) instead of or in addition to AL_HEATING_DEMAND because only that works for me.
I don't now the difference between AL_HEATING_DEMAND and AL_HEATING_ACTIVE but finally i'm interested in the valve.
And I could derive AL_HEATING_ACTIVE from AL_HEATING_ACTIVE easily, with a JS Transform at chanellevel
Another way could be to let me manipulate the opd/idp channels like in the kjoglums-binding for each thing rsp. channel.
The text was updated successfully, but these errors were encountered:
currently the binding works with
AL_HEATING_DEMAND opd0013 pairing id 333(0x14d)
That works fine for 6 of my 7 RTCs. But at one RTC the value remains always zero. I think this is a Busch Jäger Bug. At this RTC the
AL_HEATING_ACTIVE odp0011 pairing id 331(0x14b) remains always zero too.
I can see this behaviour in this binding, the kjoglums-binding and even at the swagger webinterface.
The speciality of this RTC ist, that it is connected to my second (6-gang heating actuator). The other 6 are connected to the first one.
The officialBJ support refers to the german support forum, so I tried it here in the german support forum.
https://community.busch-jaeger.de/frage-ansehen/raumtemperaturregler-unterschied-zwischen-al_heating_demand-und-al_actuating_value_heating
Nevertheless I want you to ask, to integrate
AL_ACTUATING_VALUE_HEATING opd000 pairing id 48(0x30) instead of or in addition to AL_HEATING_DEMAND because only that works for me.
I don't now the difference between AL_HEATING_DEMAND and AL_HEATING_ACTIVE but finally i'm interested in the valve.
And I could derive AL_HEATING_ACTIVE from AL_HEATING_ACTIVE easily, with a JS Transform at chanellevel
Another way could be to let me manipulate the opd/idp channels like in the kjoglums-binding for each thing rsp. channel.