forked from openhab/openhab1-addons
/
Nibe F750 variable information.csv
We can make this file beautiful and searchable if this error is corrected: Any value after quoted field isn't allowed in line 6.
270 lines (270 loc) · 24.1 KB
/
Nibe F750 variable information.csv
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
ModbusManager 1.0.8
20150530
Product: F750
Database: 3152
Title;Info;ID;Unit;Size;Factor;Min;Max;Default;Mode
"BT1 Outdoor temp";"Outdoor temperature";40004;"°C";s16;10;0;0;0;R;
"EB23-BT2 Supply temp S4";"Supply temperature for system 4";40005;"°C";s16;10;0;0;0;R;
"EB22-BT2 Supply temp S3";"Supply temperature for system 3";40006;"°C";s16;10;0;0;0;R;
"EB21-BT2 Supply temp S2";"Supply temperature for system 2";40007;"°C";s16;10;0;0;0;R;
"BT2 Supply temp S1";"Supply temperature for system 1";40008;"°C";s16;10;0;0;0;R;
"EB100-EP14-BT3 Return temp";"Return temperature";40012;"°C";s16;10;0;0;0;R;
"BT7 Hot Water top";"";40013;"°C";s16;10;0;0;0;R;
"BT6 Hot Water load";"";40014;"°C";s16;10;0;0;0;R;
"EB100-EP14-BT12 Cond. out";"";40017;"°C";s16;10;0;0;0;R;
"EB100-EP14-BT14 Hot gas temp";"";40018;"°C";s16;10;0;0;0;R;
"EB100-EP14-BT15 Liquid line";"";40019;"°C";s16;10;0;0;0;R;
"EB100-BT16 Evaporator temp";"";40020;"°C";s16;10;0;0;0;R;
"EB100-EP14-BT17 Suction";"";40022;"°C";s16;10;0;0;0;R;
"EB100-BT20 Exhaust air temp.";"";40025;"°C";s16;10;0;0;0;R;
"EB100-BT21 Vented air temp.";"";40026;"°C";s16;10;0;0;0;R;
"EB23-BT50 Room Temp S4";"";40030;"°C";s16;10;0;0;0;R;
"EB22-BT50 Room Temp S3";"";40031;"°C";s16;10;0;0;0;R;
"EB21-BT50 Room Temp S2";"";40032;"°C";s16;10;0;0;0;R;
"BT50 Room Temp S1";"";40033;"°C";s16;10;0;0;0;R;
"EQ1-BT64 PCS4 Supply Temp";"PCS4 Only";40045;"°C";s16;10;0;0;0;R;
"EB100-BT61 Supply Radiator Temp";"";40047;"°C";s16;10;0;0;0;R;
"EB100-BT62 Return Radiator Temp";"";40048;"°C";s16;10;0;0;0;R;
"EB100-BS1 Air flow";"";40050;"";s16;10;0;0;0;R;
"EB100-BS1 Air flow unfiltered";"Unfiltered air flow value";40051;"";s16;100;0;0;0;R;
"EB100-FD1 Temperature limiter";"";40054;"";s16;1;0;0;0;R;
"BT1 Average";"EB100-BT1 Outdoor temperature average";40067;"°C";s16;10;0;0;0;R;
"BT25 external supply temp";"";40071;"°C";s16;10;0;0;0;R;
"BF1 Flow";"Current flow";40072;"l/m";s16;10;0;0;0;R;
"EB100-FR1 Anode Status";"";40074;"";s16;1;0;0;0;R;
"BT6 external water heater load temp.";"This includes DEW and SCA accessory";40077;"°C";s16;10;0;0;0;R;
"BT7 external water heater top temp.";"This includes DEW and SCA accessory";40078;"°C";s16;10;0;0;0;R;
"EB100-BE3 Current Phase 3";"";40079;"A";s32;10;0;0;0;R;
"EB100-BE2 Current Phase 2";"";40081;"A";s32;10;0;0;0;R;
"EB100-BE1 Current Phase 1";"";40083;"A";s32;10;0;0;0;R;
"EB100-BT20 Exhaust air temp.";"";40107;"°C";s16;10;0;0;0;R;
"EB100-BT20 Exhaust air temp.";"";40108;"°C";s16;10;0;0;0;R;
"EB100-BT20 Exhaust air temp.";"";40109;"°C";s16;10;0;0;0;R;
"EB100-BT21 Vented air temp.";"";40110;"°C";s16;10;0;0;0;R;
"EB100-BT21 Vented air temp.";"";40111;"°C";s16;10;0;0;0;R;
"EB100-BT21 Vented air temp.";"";40112;"°C";s16;10;0;0;0;R;
"EB23-BT3 Return temp S4";"Return temperature for system 4";40127;"°C";s16;10;0;0;0;R;
"EB22-BT3 Return temp S3";"Return temperature for system 3";40128;"°C";s16;10;0;0;0;R;
"EB21-BT3 Return temp S2";"Return temperature for system 2";40129;"°C";s16;10;0;0;0;R;
"AZ2-BT22 Supply air temp. SAM";"";40141;"ºC";s16;10;0;0;0;R;
"AZ2-BT23 Outdoor temp. SAM";"";40142;"ºC";s16;10;0;0;0;R;
"AZ2-BT68 Flow temp. SAM";"Heat medium flow temperature to SAM module";40143;"°C";s16;10;0;0;0;R;
"AZ2-BT69 Return temp. SAM";"Heat medium return temperature from SAM module";40144;"°C";s16;10;0;0;0;R;
"EP30-BT53 Solar Panel Temp";"";40157;"°C";s16;10;0;0;0;R;
"EP30-BT54 Solar Load Temp";"";40158;"°C";s16;10;0;0;0;R;
"Software version";"";43001;"";u16;1;0;0;0;R;
"Degree Minutes";"";43005;"";s16;10;-30000;30000;0;R/W;
"Calculated Supply Temperature S4";"";43006;"°C";s16;10;0;0;0;R;
"Calculated Supply Temperature S3";"";43007;"°C";s16;10;0;0;0;R;
"Calculated Supply Temperature S2";"";43008;"°C";s16;10;0;0;0;R;
"Calculated Supply Temperature S1";"";43009;"°C";s16;10;0;0;0;R;
"Freeze Protection Status";"1 = Freeze protection active";43013;"";u8;1;0;0;0;R;
"t. after start timer";"";43061;"";u8;1;0;0;0;R;
"t. after mode change";"Time after mode change";43062;"";u8;1;0;0;0;R;
"HMF dT set.";"set point delta T for the heat medium flow";43064;"";s16;10;0;0;0;R;
"HMF dT act.";"Current value of the delta T for the heat medium flow";43065;"";s16;10;0;0;0;R;
"Tot. op.time add.";"Total electric additive operation time";43081;"h";s32;10;0;9999999;0;R;
"Int. el.add. Power";"Current power from the internal electrical addition";43084;"kW";s16;100;0;0;0;R;
"Prio";"Indicates what heating action (HW/heat/pool) currently prioritised 10=Off 20=Hot Water 30=Heat 40=Pool 41=Pool 2 50=Transfer 60=Cooling";43086;"";u8;1;0;0;0;R;
"Int. el.add. State";"State of the internal electrical addition";43091;"";u8;1;0;0;0;R;
"Fan speed current";"The current fan speed after scheduling and blocks are considered";43108;"%";u8;1;0;0;0;R;
"Compr. current min.freq.";"The current minimum frequency of the compressor";43122;"Hz";s16;1;0;0;0;R;
"Compr. current max.freq.";"The current maximum frequency of the compressor";43123;"Hz";s16;1;0;0;0;R;
"Airflow ref.";"Reference value for the airflow.";43124;"";s16;10;0;0;0;R;
"Inverter com. timer";"This value shows the time since last communication with the inverter";43132;"sec";u16;1;0;0;0;R;
"Inverter drive status";"";43133;"";u16;1;0;0;0;R;
"Compr. current freq.";"The frequency of the compressor at the moment";43136;"Hz";u16;10;0;0;0;R;
"Inverter alarm code";"";43137;"";u16;1;0;0;0;R;
"Inverter fault code";"";43138;"";u16;1;0;0;0;R;
"compr. temp.";"Current compressor temparture";43140;"°C";s16;10;0;0;0;R;
"compr. in power";"The power delivered from the inverter to the compressor";43141;"W";u16;1;0;0;0;R;
"Compr. energy total";"Total compressor energy in kWh";43144;"kWh";u32;100;0;9999999;0;R;
"Compr. in current";"The current delivered from the inverter to the compressor";43147;"A";s16;1;0;0;0;R;
"Chargepump speed";"";43181;"";s16;1;0;0;0;R;
"Compr. freq. setpoint";"The targeted compressor frequency";43182;"Hz";u16;1;0;0;0;R;
"Tot. HW op.time add.";"Total electric additive operation time in hot water mode";43239;"h";s32;10;0;9999999;0;R;
"Compr. energy HW";"Compressor energy during hot water production in kWh";43305;"kWh";u32;100;0;9999999;0;R;
"compr. in power mean";"Mean power delivered from the inverter to the compressor. Mean is calculated every 10 seconds.";43375;"W";s16;1;0;0;0;R;
"Inverter mem error code";"";43382;"";u16;1;0;0;0;R;
"Compressor starts EB100-EP14";"Number of compressorer starts";43416;"";s32;1;0;9999999;0;R;
"Tot. op.time compr. EB100-EP14";"Total compressorer operation time";43420;"h";s32;1;0;9999999;0;R;
"Tot. HW op.time compr. EB100-EP14";"Total compressorer operation time in hot water mode";43424;"h";s32;1;0;9999999;0;R;
"Compressor State EP14";"20 = Stopped, 40 = Starting, 60 = Running, 100 = Stopping";43427;"";u8;1;0;0;0;R;
"Compressor status EP14";"Indicates if the compressor is supplied with power 0=Off 1=On";43435;"";u8;1;0;0;0;R;
"HM-pump Status EP14";"Status of the circ. pump";43437;"";u8;1;0;0;0;R;
"PCA-Base Relays EP14";"Indicates the active relays on the PCA-Base card. The information is binary encoded";43514;"";u8;1;0;0;0;R;
"PCA-Power Relays EP14";"Indicates the active relays on the PCA-Power card. The information is binary encoded";43516;"";u8;1;0;0;0;R;
"Calculated supply air temp.";"";43542;"ºC";s16;10;0;0;0;R;
"External supply air accessory relays";"Indicates the status of the relays on the external supply air accessory. The information is binary encoded. B0: relay K1 (QN40 close signal). B1: relay K2 (QN40 open signal)";44258;"";u8;1;0;0;0;R;
"Calc. Cooling Supply Temperature S4";"";44267;"°C";s16;10;0;0;0;R;
"Calc. Cooling Supply Temperature S3";"";44268;"°C";s16;10;0;0;0;R;
"Calc. Cooling Supply Temperature S2";"";44269;"°C";s16;10;0;0;0;R;
"Calc. Cooling Supply Temperature S1";"";44270;"°C";s16;10;0;0;0;R;
"SCA accessory relays";"Indicates the status of the relays on the SCA accessory. The information is binary encoded. B0: relay K1 (Solar pump). B1: relay K2 (Solar Cooling Pump) B2: relay K3 (QN28)";44317;"";u8;1;0;0;0;R;
"Software release";"";44331;"";u8;1;0;0;0;R;
"Alarm number";"The value indicates the most severe current alarm";45001;"";s16;1;0;0;0;R;
"HW charge offset";"Offset of HW charge temperature from the stop temperature";47062;"°C";s8;10;0;0;0;R/W;
"Floor drying timer";"";47291;"hrs";u16;1;0;10000;0;R;
"Heat curve S4";"Heat curve to use see manual for the different curves.";47004;"";s8;1;0;15;9;R/W;
"Heat curve S3";"Heat curve to use see manual for the different curves.";47005;"";s8;1;0;15;9;R/W;
"Heat curve S2";"Heat curve to use see manual for the different curves.";47006;"";s8;1;0;15;9;R/W;
"Heat curve S1";"Heat curve to use see manual for the different curves.";47007;"";s8;1;0;15;9;R/W;
"Offset S4";"Offset of the heat curve";47008;"";s8;1;-10;10;0;R/W;
"Offset S3";"Offset of the heat curve";47009;"";s8;1;-10;10;0;R/W;
"Offset S2";"Offset of the heat curve";47010;"";s8;1;-10;10;0;R/W;
"Offset S1";"Offset of the heat curve";47011;"";s8;1;-10;10;0;R/W;
"Min Supply System 4";"";47012;"°C";s16;10;50;700;200;R/W;
"Min Supply System 3";"";47013;"°C";s16;10;50;700;200;R/W;
"Min Supply System 2";"";47014;"°C";s16;10;50;700;200;R/W;
"Min Supply System 1";"";47015;"°C";s16;10;50;700;200;R/W;
"Max Supply System 4";"";47016;"°C";s16;10;50;700;600;R/W;
"Max Supply System 3";"";47017;"°C";s16;10;50;700;600;R/W;
"Max Supply System 2";"";47018;"°C";s16;10;50;700;600;R/W;
"Max Supply System 1";"";47019;"°C";s16;10;50;700;600;R/W;
"Own Curve P7";"User defined curve point";47020;"°C";s8;1;0;80;15;R/W;
"Own Curve P6";"User defined curve point";47021;"°C";s8;1;0;80;15;R/W;
"Own Curve P5";"User defined curve point";47022;"°C";s8;1;0;80;26;R/W;
"Own Curve P4";"User defined curve point";47023;"°C";s8;1;0;80;32;R/W;
"Own Curve P3";"User defined curve point";47024;"°C";s8;1;0;80;35;R/W;
"Own Curve P2";"User defined curve point";47025;"°C";s8;1;0;80;40;R/W;
"Own Curve P1";"User defined curve point";47026;"°C";s8;1;0;80;45;R/W;
"Point offset outdoor temp.";"Outdoor temperature point where the heat curve is offset";47027;"°C";s8;1;-40;30;0;R/W;
"Point offset";"Amount of offset at the point offset temperature";47028;"°C";s8;1;-10;10;0;R/W;
"External adjustment S4";"Change of the offset of the heat curve when closing the external adjustment input";47029;"";s8;1;-10;10;0;R/W;
"External adjustment S3";"Change of the offset of the heat curve when closing the external adjustment input";47030;"";s8;1;-10;10;0;R/W;
"External adjustment S2";"Change of the offset of the heat curve when closing the external adjustment input";47031;"";s8;1;-10;10;0;R/W;
"External adjustment S1";"Change of the offset of the heat curve when closing the external adjustment input";47032;"";s8;1;-10;10;0;R/W;
"External adjustment with room sensor S4";"Room temperature setting when closing the external adjustment input";47033;"°C";s16;10;50;300;200;R/W;
"External adjustment with room sensor S3";"Room temperature setting when closing the external adjustment input";47034;"°C";s16;10;50;300;200;R/W;
"External adjustment with room sensor S2";"Room temperature setting when closing the external adjustment input";47035;"°C";s16;10;50;300;200;R/W;
"External adjustment with room sensor S1";"Room temperature setting when closing the external adjustment input";47036;"°C";s16;10;50;300;200;R/W;
"Hot water mode";" 0=Economy 1=Normal 2=Luxury";47041;"";s8;1;0;2;1;R/W;
"Start temperature HW Luxury";"Start temperature for heating water";47043;"°C";s16;10;50;700;470;R/W;
"Start temperature HW Normal";"Start temperature for heating water";47044;"°C";s16;10;50;700;450;R/W;
"Start temperature HW Economy";"Start temperature for heating water";47045;"°C";s16;10;50;700;380;R/W;
"Stop temperature Periodic HW";"Temperature where hot water generation will stop";47046;"°C";s16;10;550;700;550;R/W;
"Stop temperature HW Luxury";"Temperature where hot water generation will stop";47047;"°C";s16;10;50;700;520;R/W;
"Stop temperature HW Normal";"Temperature where hot water generation will stop";47048;"°C";s16;10;50;700;500;R/W;
"Stop temperature HW Economy";"Temperature where hot water generation will stop";47049;"°C";s16;10;50;700;430;R/W;
"Periodic HW";"Activates the periodic hot water generation";47050;"";s8;1;0;1;1;R/W;
"Periodic HW Interval";"Interval between Periodic hot water sessions";47051;"days";s8;1;1;90;14;R/W;
"Run time HWC";"Run time for the hot water circulation system";47054;"min";s8;1;1;60;3;R/W;
"Still time HWC";"Still time for the hot water circulation system";47055;"min";s8;1;0;60;12;R/W;
"Manual compfreq HW";"Should the compressor frequency be manual set in HW?";47092;"";u8;1;0;0;0;R/W;
"Manual compfreq speed HW";"Manual compressor frequency in HW?";47093;"Hz";u16;1;0;0;0;R/W;
"Sec per compfreq step";"Time between changes of the copmpressor frequency";47094;"s";u8;1;0;0;0;R/W;
"Max compfreq step";"Largest allowed change of compressor frequency in normal run";47095;"Hz";u8;1;0;0;0;R/W;
"Manual compfreq Heating";"Should the compressor frequency be manual set in Heating?";47096;"";u8;1;0;0;0;R/W;
"Min speed after start";"Time with minimum compressor frequency when heating demand occurs";47097;"Min";u8;1;0;0;0;R/W;
"Min speed after HW";"Should the compressor frequency be manual set in HW?";47098;"Min";u8;1;0;0;0;R/W;
"GMz";"Compressor frequency regulator GMz";47099;"";u8;1;0;0;0;R/W;
"Max diff VBF-BerVBF";"Largest allowed difference between Supply and calc supply";47100;"°C";u8;10;0;0;0;R/W;
"Comp freq reg P";"Compressor frequency regulator P";47101;"";u8;1;0;0;0;R/W;
"Comp freq max delta F";"Maximum change of copmpressor frequency in compressor frequency regulator";47102;"Hz";s8;1;0;0;0;R/W;
"Min comp freq";"Minimum allowed compressor frequency";47103;"Hz";s16;1;0;0;0;R/W;
"Max comp freq";"Maximum allowed compressor frequency";47104;"Hz";s16;1;0;0;0;R/W;
"Comp freq heating";"Compressor frequency used in heating mode";47105;"Hz";s16;1;0;0;0;R/W;
"Language";"Display language in the heat pump 0=English 1=Svenska 2=Deutsch 3=Francais 4=Espanol 5=Suomi 6=Lietuviu 7=Cesky 8=Polski 9=Nederlands 10=Norsk 11=Dansk 12=Eesti 13=Latviesu 16=Magyar";47131;"";s8;1;0;18;0;R/W;
"Period HW";"";47134;"min";u8;1;0;180;20;R/W;
"Period Heat";"";47135;"min";u8;1;0;180;20;R/W;
"Period Pool";"";47136;"min";u8;1;0;180;20;R/W;
"Operational mode heat medium pump";" 10=Intermittent 20=Continous 30=Economy 40=Auto";47138;"";u8;1;10;40;40;R/W;
"DM start heating";"The value the degree minutes needed to be reached for the pump to start heating";47206;"";s16;1;-1000;-30;-60;R/W;
"DM start cooling";"The value the degree minutes needed to be reached for the pump to start cooling";47207;"";s16;1;0;0;0;R/W;
"DM start add.";"The value the degree minutes needed to be reached for the pump to start electric addition";47208;"";s16;1;0;0;0;R/W;
"DM between add. steps";"The number of degree minutes between start of each electric addition step";47209;"";s16;1;0;0;0;R/W;
"DM start add. with shunt";"";47210;"";s16;1;-2000;-30;-400;R/W;
"Max int add. power";"";47212;"kW";s16;100;0;4500;600;R/W;
"Fuse";"Size of the fuse that the HP is connected to";47214;"A";u8;1;1;200;16;R/W;
"Exhaust Fan speed 4";"";47261;"%";u8;1;0;100;100;R/W;
"Exhaust Fan speed 3";"";47262;"%";u8;1;0;100;80;R/W;
"Exhaust Fan speed 2";"";47263;"%";u8;1;0;100;30;R/W;
"Exhaust Fan speed 1";"";47264;"%";u8;1;0;100;0;R/W;
"Exhaust Fan speed normal";"";47265;"%";u8;1;0;100;65;R/W;
"Supply Fan speed 4";"";47266;"%";u8;1;0;100;90;R/W;
"Supply Fan speed 3";"";47267;"%";u8;1;0;100;70;R/W;
"Supply Fan speed 2";"";47268;"%";u8;1;0;100;25;R/W;
"Supply Fan speed 1";"";47269;"%";u8;1;0;100;0;R/W;
"Supply Fan speed normal";"";47270;"%";u8;1;0;100;60;R/W;
"Fan return time 4";"Time from a changed fan speed until it returns to normal speed";47271;"h";u8;1;1;99;4;R/W;
"Fan return time 3";"Time from a changed fan speed until it returns to normal speed";47272;"h";u8;1;1;99;4;R/W;
"Fan return time 2";"Time from a changed fan speed until it returns to normal speed";47273;"h";u8;1;1;99;4;R/W;
"Fan return time 1";"Time from a changed fan speed until it returns to normal speed";47274;"h";u8;1;1;99;4;R/W;
"Filter Reminder period";"Time between the reminder of filter replacement/cleaning.";47275;"Months";u8;1;1;24;3;R/W;
"Floor drying";" 0=Off 1=On";47276;"";u8;1;0;1;0;R/W;
"Floor drying period 7";"Days each period is active";47277;"days";u8;1;0;30;2;R/W;
"Floor drying period 6";"Days each period is active";47278;"days";u8;1;0;30;2;R/W;
"Floor drying period 5";"Days each period is active";47279;"days";u8;1;0;30;2;R/W;
"Floor drying period 4";"Days each period is active";47280;"days";u8;1;0;30;3;R/W;
"Floor drying period 3";"Days each period is active";47281;"days";u8;1;0;30;2;R/W;
"Floor drying period 2";"Days each period is active";47282;"days";u8;1;0;30;2;R/W;
"Floor drying period 1";"Days each period is active";47283;"days";u8;1;0;30;2;R/W;
"Floor drying temp. 7";"Supply temperature each period";47284;"°C";u8;1;15;70;20;R/W;
"Floor drying temp. 6";"Supply temperature each period";47285;"°C";u8;1;15;70;30;R/W;
"Floor drying temp. 5";"Supply temperature each period";47286;"°C";u8;1;15;70;40;R/W;
"Floor drying temp. 4";"Supply temperature each period";47287;"°C";u8;1;15;70;45;R/W;
"Floor drying temp. 3";"Supply temperature each period";47288;"°C";u8;1;15;70;40;R/W;
"Floor drying temp. 2";"Supply temperature each period";47289;"°C";u8;1;15;70;30;R/W;
"Floor drying temp. 1";"Supply temperature each period";47290;"°C";u8;1;15;70;20;R/W;
"Use airflow defrost";"If reduced airflow should start defrost";47294;"";u8;1;0;0;0;R/W;
"Airflow reduction trig";"How much the airflow is allowed to be reduced before a defrost is trigged";47295;"%";u8;1;0;0;0;R/W;
"Airflow defrost done";"How much the airflow has to raise before a defrost is ended";47296;"%";u8;1;0;0;0;R/W;
"Initiate inverter";"Start initiation process of the inverter";47297;"";u8;1;0;0;0;R/W;
"Force inverter init";"Force inverter initiation process of the inverter";47298;"";u8;1;0;0;0;R/W;
"Min time defrost";"Minimum duration of the defrost";47299;"min";u8;1;0;0;0;R/W;
"DOT";"Dimensioning outdoor temperature";47300;"°C";s16;10;-400;200;-180;R/W;
"delta T at DOT";"Delta T (BT12-BT3)at dimensioning outdoor temperature";47301;"°C";s16;10;0;250;100;R/W;
"Climate system 2 accessory";"Activates the climate system 2 accessory 0=Off 1=On";47302;"";u8;1;0;1;0;R/W;
"Climate system 3 accessory";"Activates the climate system 3 accessory 0=Off 1=On";47303;"";u8;1;0;1;0;R/W;
"Climate system 4 accessory";"Activates the climate system 4 accessory 0=Off 1=On";47304;"";u8;1;0;1;0;R/W;
"Climate system 4 mixing valve amp.";"Mixing valve amplification for extra climate systems";47305;"";s8;10;1;100;10;R/W;
"Climate system 3 mixing valve amp.";"Mixing valve amplification for extra climate systems";47306;"";s8;10;1;100;10;R/W;
"Climate system 2 mixing valve amp.";"Mixing valve amplification for extra climate systems";47307;"";s8;10;1;100;10;R/W;
"Climate system 4 shunt wait";"Wait time between changes of the shunt in extra climate systems";47308;"secs";s16;10;10;300;30;R/W;
"Climate system 3 shunt wait";"Wait time between changes of the shunt in extra climate systems";47309;"secs";s16;10;10;300;30;R/W;
"Climate system 2 shunt wait";"Wait time between changes of the shunt in extra climate systems";47310;"secs";s16;10;10;300;30;R/W;
"Shunt controlled add. accessory";"Activates the shunt controlled addition accessory 0=Off 1=On";47317;"";u8;1;0;1;0;R/W;
"Shunt controlled add. min. temp.";"";47318;"°C";s8;1;5;90;55;R/W;
"Shunt controlled add. min. runtime";"";47319;"hrs";u8;1;0;48;12;R/W;
"Shunt controlled add. mixing valve amp.";"Mixing valve amplification for shunt controlled add.";47320;"";s8;10;1;100;10;R/W;
"Shunt controlled add. mixing valve wait";"Wait time between changes of the shunt in shunt controlled add.";47321;"secs";s16;1;10;300;30;R/W;
"SMS40 accessory";"Activates the SMS40 accessory";47352;"";u8;1;0;1;0;R/W;
"Allow Additive Heating";"Whether to allow additive heating (only valid for operational mode Manual)";47370;"";u8;1;0;1;1;R/W;
"Allow Heating";"Whether to allow heating (only valid for operational mode Manual or Add. heat only)";47371;"";u8;1;0;1;1;R/W;
"Allow Cooling";"Whether to allow cooling (only valid for operational mode Manual or Add. heat only)";47372;"";u8;1;0;1;1;R/W;
"Max diff. comp.";"";47378;"°C";s16;10;10;250;100;R/W;
"Max diff. add.";"";47379;"°C";s16;10;10;240;70;R/W;
"Date format";" 1=DD-MM-YY 2=YY-MM-DD";47384;"";u8;1;1;2;1;R/W;
"Time format";" 12=12 hours 24=24 Hours";47385;"";u8;1;12;24;24;R/W;
"HW production";"Activates hot water production where applicable 0=Off 1=On";47387;"";u8;1;0;1;0;R/W;
"Alarm lower room temp.";"Lowers the room temperature during red light alarms to notify the occupants of the building that something is the matter 0=Off 1=On";47388;"";u8;1;0;1;0;R/W;
"Alarm lower HW temp.";"Lowers the hot water temperature during red light alarms to notify the occupants of the building that something is the matter 0=Off 1=On";47389;"";u8;1;0;1;1;R/W;
"Use room sensor S4";"When activated the system uses the room sensor 0=Off 1=On";47391;"";u8;1;0;1;0;R/W;
"Use room sensor S3";"When activated the system uses the room sensor 0=Off 1=On";47392;"";u8;1;0;1;0;R/W;
"Use room sensor S2";"When activated the system uses the room sensor 0=Off 1=On";47393;"";u8;1;0;1;0;R/W;
"Use room sensor S1";"When activated the system uses the room sensor 0=Off 1=On";47394;"";u8;1;0;1;0;R/W;
"Room sensor setpoint S4";"Sets the room temperature setpoint for the system";47395;"°C";s16;10;50;300;200;R/W;
"Room sensor setpoint S3";"Sets the room temperature setpoint for the system";47396;"°C";s16;10;50;300;200;R/W;
"Room sensor setpoint S2";"Sets the room temperature setpoint for the system";47397;"°C";s16;10;50;300;200;R/W;
"Room sensor setpoint S1";"Sets the room temperature setpoint for the system";47398;"°C";s16;10;50;300;200;R/W;
"Room sensor factor S4";"Setting of how much the difference between set and actual room temperature should affect the supply temperature.";47399;"";u8;10;0;60;20;R/W;
"Room sensor factor S3";"Setting of how much the difference between set and actual room temperature should affect the supply temperature.";47400;"";u8;10;0;60;20;R/W;
"Room sensor factor S2";"Setting of how much the difference between set and actual room temperature should affect the supply temperature.";47401;"";u8;10;0;60;20;R/W;
"Room sensor factor S1";"Setting of how much the difference between set and actual room temperature should affect the supply temperature.";47402;"";u8;10;0;60;20;R/W;
"Speed circ.pump Pool";"";47415;"%";u8;1;0;100;70;R/W;
"Speed circ.pump Cooling";"";47417;"%";u8;1;0;100;70;R/W;
"preset flow clim. sys.";"Preset flow setting for climate system. 0 = manual setting, 1 = radiator, 2 = floor heating, 3 = radiator + floor heating.";47442;"";u8;1;0;3;1;R/W;
"Max time defrost";"Maximum duration of the defrost";47473;"min";u8;1;0;0;0;R/W;
"Night cooling";"If the fan should have a higher speed when there is a high room temp and a low outdoor temp. 0=Off 1=On";47537;"";u8;1;0;1;0;R/W;
"Start room temp. night cooling";"";47538;"°C";u8;1;20;30;25;R/W;
"Night Cooling Min. diff.";"Minimum difference between room temp and outdoor temp to start night cooling";47539;"°C";u8;1;3;10;6;R/W;
"DEW accessory";"Activates the DEW accessory";47555;"";u8;1;0;1;0;R/W;
"Operational mode";"The operational mode of the heat pump 0=Auto 1=Manual 2=Add. heat only";47570;"";u8;1;0;0;0;R/W;
"Operational mode charge pump";"";48134;"";u8;1;10;20;20;R/W;
"SAM supply air curve: outdoor temp T3";"The supply air curve is defined by 3 supply air temperatures at 3 different outdoor temperatures T1, T2 and T3.";48158;"°C";s16;10;-400;200;150;R/W;
"SAM supply air curve: outdoor temp T2";"The supply air curve is defined by 3 supply air temperatures at 3 different outdoor temperatures T1, T2 and T3.";48159;"°C";s16;10;-390;190;0;R/W;
"SAM supply air curve: outdoor temp T1";"The supply air curve is defined by 3 supply air temperatures at 3 different outdoor temperatures T1, T2 and T3.";48160;"°C";s16;10;-400;200;-150;R/W;
"SAM supply air curve: supply air temp at T3";"The supply air curve is defined by 3 supply air temperatures at 3 different outdoor temperatures T1, T2 and T3.";48161;"°C";s16;10;160;520;220;R/W;
"SAM supply air curve: supply air temp at T2";"The supply air curve is defined by 3 supply air temperatures at 3 different outdoor temperatures T1, T2 and T3.";48162;"°C";s16;10;160;520;220;R/W;
"SAM supply air curve: supply air temp at T1";"The supply air curve is defined by 3 supply air temperatures at 3 different outdoor temperatures T1, T2 and T3.";48163;"°C";s16;10;160;520;220;R/W;
"SCA accessory";"Activates the SCA accessory";48201;"";u8;1;0;1;0;R/W;