Parametric EQs

In case of using parametric equalizer, apply preamp of -6.1dB and build filters manually with these parameters. The first 5 filters can be used independently. When using independent subset of filters, apply preamp of -5.9 dB.

Type Fc Q Gain
Peaking 804 Hz 1.35 4.2 dB
Peaking 2112 Hz 0.99 3.2 dB
Peaking 3097 Hz 3.23 -7.4 dB
Peaking 5449 Hz 4.29 -10.0 dB
Peaking 10274 Hz 2.29 5.9 dB
Peaking 29 Hz 0.4 -1.4 dB
Peaking 126 Hz 0.41 -2.4 dB
Peaking 422 Hz 1.36 1.6 dB
Peaking 13157 Hz 1.29 3.7 dB
Peaking 19705 Hz 0.49 -13.2 dB

Fixed Band EQs

In case of using fixed band (also called graphic) equalizer, apply preamp of -4.6dB (if available) and set gains manually with these parameters.

Type Fc Q Gain
Peaking 31 Hz 1.41 -1.9 dB
Peaking 62 Hz 1.41 -2.1 dB
Peaking 125 Hz 1.41 -2.4 dB
Peaking 250 Hz 1.41 -1.3 dB
Peaking 500 Hz 1.41 2.4 dB
Peaking 1000 Hz 1.41 3.8 dB
Peaking 2000 Hz 1.41 2.6 dB
Peaking 4000 Hz 1.41 -6.5 dB
Peaking 8000 Hz 1.41 3.0 dB
Peaking 16000 Hz 1.41 -4.1 dB