Skip to content

Latest commit

 

History

History
 
 

Grado SR80i

See usage instructions for more options and info.

Parametric EQs

In case of using parametric equalizer, apply preamp of -6.6dB and build filters manually with these parameters. The first 5 filters can be used independently. When using independent subset of filters, apply preamp of -6.6 dB.

Type Fc Q Gain
Peaking 31 Hz 0.43 6.3 dB
Peaking 1262 Hz 0.23 3.9 dB
Peaking 2118 Hz 2.08 -10.3 dB
Peaking 6496 Hz 0.89 -5.6 dB
Peaking 17454 Hz 0.24 -2.9 dB
Peaking 2794 Hz 4.39 -2.7 dB
Peaking 3466 Hz 2.92 3.5 dB
Peaking 4607 Hz 3.46 -4.1 dB
Peaking 5721 Hz 3 2.6 dB
Peaking 6969 Hz 4.34 -1.5 dB

Fixed Band EQs

In case of using fixed band (also called graphic) equalizer, apply preamp of -7.6dB (if available) and set gains manually with these parameters.

Type Fc Q Gain
Peaking 31 Hz 1.41 6.7 dB
Peaking 62 Hz 1.41 3.6 dB
Peaking 125 Hz 1.41 1.1 dB
Peaking 250 Hz 1.41 1.4 dB
Peaking 500 Hz 1.41 2.4 dB
Peaking 1000 Hz 1.41 4.2 dB
Peaking 2000 Hz 1.41 -5.8 dB
Peaking 4000 Hz 1.41 -0.6 dB
Peaking 8000 Hz 1.41 -6.1 dB
Peaking 16000 Hz 1.41 -4.0 dB

Graphs