Notifications
You must be signed in to change notification settings - Fork 0
/
NEWS
281 lines (267 loc) · 10.7 KB
/
NEWS
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
0.2.2 (2013-11-04)
------------------
Note: This release does NOT change the libsigrok API. While new config keys,
config info types, and unit codes have been added (additional enum
entries / numbers), no existing interfaces were added/changed/removed.
Frontends should continue to work fine without recompiling or relinking.
* New supported hardware:
- Logic analyzers:
- Saleae Logic16
- Thermometers:
- Center 309
- UNI-T UT325
- Voltcraft K204
- Multimeters:
- ISOTECH IDM103N
- Metex M-4650CR
- Norma DM950
- Voltcraft M-4650CR
- Energy meters:
- EDF Teleinfo
* New config keys:
- SR_CONF_VOLTAGE_THRESHOLD
- SR_CONF_EXTERNAL_CLOCK
- SR_CONF_SWAP
- SR_CONF_ENERGYMETER
* New config info types:
- SR_T_DOUBLE_RANGE
* New units:
- SR_UNIT_REVOLUTIONS_PER_MINUTE
- SR_UNIT_VOLT_AMPERE
- SR_UNIT_WATT
- SR_UNIT_WATT_HOUR
* New input modules:
- csv (comma-separated values)
* Bump required libzip version to >= 0.10.
* uni-t-dmm: This driver now requires the specification of the USB VID/PID
of the cable that is used. Example for sigrok-cli:
- Old: sigrok-cli --driver voltcraft-vc820 ...
- New: sigrok-cli --driver voltcraft-vc820:conn=1a86.e008 ...
* openbench-logic-sniffer:
- Initial test pattern support (SR_CONF_PATTERN_MODE).
- Initial external clock support (SR_CONF_EXTERNAL_CLOCK).
- Initial channel swap support (SR_CONF_SWAP).
- Various minor fixes and improvements.
* When a frontend adds a device instance to a running session, start
acquisition on it. This helps with the collectd use-case where devices
can be removed and added dynamically while a session is running.
* rigol-ds1xx2: Support newer Linux kernels with USBTMC in /sys/class/usbmisc.
* rigol-ds1xx2: Also detect the Rigol DS1152E/DS1152D.
* agilent-dmm: Fix a segfault happening in certain cases.
* output/analog: Support all currently known MQFLAGs.
* Fix a minor compile issue due to an incorrect #include.
* Fix two compile issues on FreeBSD (bug #185).
* es519xx: New generic parser for various Cyrustek DMM ICs.
* es51922/fs9721/fs9922/metex14: Use diode MQFLAG (bug #141).
* voltcraft-vc830: Fix diode mode handling (bug #142).
* Add the missing HACKING file to the tarball.
* README.devices: Updates/notes for newly added devices.
0.2.1 (2013-08-07)
------------------
Note: This release does NOT change the libsigrok API. While new config keys,
config info types, and error codes have been added (additional enum
entries / numbers), no existing interfaces were added/changed/removed.
Frontends should continue to work fine without recompiling or relinking.
* New supported hardware:
- Logic analyzers:
- IKALOGIC Scanalogic-2
- IKALOGIC ScanaPLUS
- Sound level meters:
- CEM DT-8852
- Kecheng KC-330B
- Multimeters:
- UNI-T UT60A
- UNI-T UT60E
- Voltcraft M-3650D
- Voltcraft VC-830
* Drop the Tecpel DMM-8060 (doesn't have PC connectivity).
* New config keys:
- SR_CONF_SPL_WEIGHT_FREQ
- SR_CONF_SPL_WEIGHT_TIME
- SR_CONF_SPL_MEASUREMENT_RANGE
- SR_CONF_HOLD_MIN
- SR_CONF_HOLD_MAX
- SR_CONF_POWER_OFF
- SR_CONF_DATA_SOURCE
* New config info types:
- SR_T_UINT64_RANGE
* New error codes:
- SR_ERR_TIMEOUT
* Always link against libm, the math library (bug #115).
* Fix a bug in sr_si_string_u64() at al (bug #73).
* output/csv: Fix incorrect probe order.
* alsa: Fix a double-free issue (bug #129).
* zeroplus-logic-cube: Fix a bug in the driver cleanup code.
* ikalogic-scanalogic2: Use GET_REPORT (bug #130).
* uni-t-dmm: Fix a bug breaking the UNI-T UT61E (bug #136).
* Various internal consistency fixes and code cleanups.
* Improved Doxygen documentation.
* Fixed various memory leaks.
0.2.0 (2013-05-04)
------------------
Note: This release DOES change the libsigrok API. That means it is NOT
backwards-compatible and frontends will need updates.
* Support for analog sources (oscilloscopes, DMMs, data loggers) was added.
* New supported hardware:
- Logic analyzers:
- CWAV USBee DX
- ZEROPLUS LAP-16128U
- Oscilloscopes:
- Hantek DSO-2090 (USB scope)
- Rigol DS1052D
- Rigol DS1052E
- Rigol DS1102D
- Rigol DS1102E
- Multimeters:
- Agilent U1231A
- Agilent U1232A
- Agilent U1233A
- Brymen BM857
- Digitek DT4000ZC
- Fluke 187
- Fluke 189
- Fluke 287
- Fluke 289
- Fluke ScopeMeter 199B
- MASTECH MAS345
- Metex ME-31
- Metex M-3640D
- PCE PCE-DM32
- PeakTech 3410
- PeakTech 4370
- RadioShack 22-168
- RadioShack 22-805
- RadioShack 22-812
- Tecpel DMM-8060
- Tecpel DMM-8061
- TekPower TP4000ZC
- UNI-T UT61D
- UNI-T UT61E
- V&A VA18B
- Victor 70C
- Victor 86C
- Voltcraft VC-820
- Voltcraft VC-840
- Sound level meters:
- Colead SL-5868P
- Tondaj SL-814
- Temperature/humidity/CO loggers:
- Lascar EL-USB and EL-USB CO series (various models)
- MIC 98581
- MIC 98583
* The limitation of max. 64 digital probes has been removed in many places.
* Added generic DMM protocol parsers usable for various DMMs, over various
cables and/or transports (e.g. same protocol over serial or USB/HID):
- Cyrustek ES51922 binary protocol.
- Fortune Semiconductor FS9721_LP3/FS9721B binary protocol.
- Fortune Semiconductor FS9922-DMM3/DMM4 binary protocol.
- Metex 14-byte ASCII protocol.
- RadioShack 22-812 binary protocol.
* zeroplus-logic-cube driver:
- Fix acquisition at some specific samplerates. Only report valid ones.
- Default to a samplerate of 1MHz.
- Fix trigger code.
- Add pre-trigger (capture ratio) setting.
- Add support for the ZEROPLUS LAP-16128U.
* fx2lafw driver:
- Add support for the CWAV USBee DX. This requires the latest version of
the fx2lafw firmware files.
- Add support for wide sampling (i.e. 16 probes instead of just 8).
- Fix multi-stage (software) triggers.
- Fix various memory leaks, firmware upload timeout bugs, and other issues.
- Various performance and memory usage improvements in the driver.
* chronovu-la8 driver:
- Add support for newer LA8 versions with USB VID/PID 0403:8867.
* demo driver:
- Various bugfixes when setting time/sample limits.
* openbench-logic-sniffer driver:
- Don't try to scan all available serial ports for OLS devices. Instead,
the serial port to use now has to be specified by the user.
- Allow disabling RLE.
* udev rules file: Add many new entries for additional devices.
* New output formats:
- analog: Prints analog values and their unit (e.g. from scopes or DMMs).
* New input formats:
- vcd: Value Change Dump format
- wav: Waveform audio file format (for analog data)
* 'binary' input format: Add support for a 'samplerate' option.
* API related changes:
- There is generated Doxygen API documentation now.
- The header that frontends should include is: <libsigrok/libsigrok.h>.
There are other headers which are installed, but those are not meant to
be included directly by the frontends.
- There were numerous API changes, additions and removals, too many to list
here. Please check the source code or Doxygen API documentation for the
current set of API functions.
* Serial port code:
- Various improvements and fixes related to multiple parameters such as
directions, baudrate, flow control, and others.
- Add support for more baudrates (e.g. very low ones such as 600/1200)
that are used in some devices.
- Add support for setting DTR/RTS.
* gnuplot files: Add sample files for CWAV USBee DX (for 8/16 bit sampling).
* Documentation updates:
- Add a README.devices file which contains various notes for users of
libsigrok about device- and/or driver-specific issues.
- Update README, HACKING, and other documents.
- Updated build dependencies list.
- The following libs are needed in more recent versions now:
- glib (required): Now must be >= 2.32.0.
- libusb-1.0 (optional): Now must be >= 1.0.9.
- The following new libs were added as (optional) dependencies:
- libasound / alsa-lib (optional): >= 1.0
- check (optional, only needed for unit tests): >= 0.9.4
* Portability:
- Various compile fixes for Windows, FreeBSD/NetBSD/OpenBSD, and Mac OS X.
- Simplify/allow/fix cross-compilation of libsigrok.
- Various bugfixes for 32bit systems.
- Various endianness fixes.
* configure:
- Add a --disable-all-drivers option. This can be overridden by
additional --enable-<drivername> options to selectively enable only some.
- Improve autodetection of libraries, and only enable drivers for which
all required libraries were found.
* Add a test suite for libsigrok with a few unit tests (the list will grow).
0.1.1 (2012-05-30)
------------------
Note: This release does NOT change the libsigrok API.
* The 'saleae-logic' driver (which depends on the Saleae firmware), has
been replaced with the new 'fx2lafw' driver, which uses an open-source
firmware for Cypress FX2 chips which is also named 'fx2lafw'.
Details: http://sigrok.org/wiki/Fx2lafw
This new driver (+ firmware) currently supports the following devices:
- ARMFLY AX-Pro
- Braintechnology USB-LPS
- EE Electronics ESLA100
- EE Electronics ESLA201A
- Robomotic MiniLogic
- Robomotic BugLogic 3
- Saleae Logic
- USBee AX
- USBee SX
- All Cypress FX2 eval boards with stock Cypress VID/PID, including:
- Lcsoft Mini Board
- Braintechnology USB Interface V2.x
Only acquisition with 8 probes is supported so far. Support for 16 probes
and support for analog signal acquisition (on devices which have these
capabilities) will be added later.
* ASIX SIGMA driver:
- Add support for the ASIX SIGMA2. This requires the latest version of
the SIGMA/SIGMA2 firmware files.
Details: http://sigrok.org/wiki/Firmware
- Various bugfixes.
* ZEROPLUS Logic Cube LAP-C (16032): Fix a segfault.
* udev file: Add entries for Robomotic BugLogic 3, Velleman PCSU1000,
Ideofy LA-08, ARMFLY AX-Pro, and Braintechnology USB Interface V2.x.
* The zlib dependency has been removed (no longer needed).
* Fix compiling with "Homebrew" (Mac OS X).
* libsigrok now expects firmware files in $prefix/share/sigrok-firmware by
default (was $prefix/share/libsigrok/firmware before).
* Fix a Makefile.am bug which caused the generated ChangeLog files being
accidentally deleted upon 'make distclean'.
* ChronoVu LA8 input file format: Improve autodetection of the file format.
We now only accept files of the size 8388613 bytes (all LA8 files have
exactly this amount of bytes).
0.1.0 (2012-04-17)
------------------
* Initial release.