tdcc: Incorrect early transitions in presence of par #662

Open
rachitnigam opened this issue Sep 10, 2021 · 4 comments · Fixed by #671
Open

tdcc: Incorrect early transitions in presence of par #662

rachitnigam opened this issue Sep 10, 2021 · 4 comments · Fixed by #671
Labels
C: Calyx Extension or change to the Calyx IL Status: Available Can be worked upon Type: Bug Bug in the implementation

Comments

@rachitnigam
Copy link
Contributor

The following program incorrectly computes the final value in y_int0 to be 0. The expected value is 1:

import "primitives/core.futil";
component main(@go go: 1, @clk clk: 1, @reset reset: 1) -> (@done done: 1) {
  cells {
    f0 = std_reg(4);
    @external y_int0 = std_mem_d1(1, 1, 1);
    comb_reg = std_reg(1);
  }
  wires {
    group zero_f0 {
      f0.write_en = 1'd1;
      f0.in = 4'd0;
      zero_f0[done] = f0.done;
    }
    group false<"static"=1> {
      comb_reg.in = 1'd0;
      comb_reg.write_en = 1'd1;
      false[done] = comb_reg.done ? 1'd1;
    }
    group true<"static"=1> {
      comb_reg.in = 1'd1;
      comb_reg.write_en = 1'd1;
      true[done] = comb_reg.done ? 1'd1;
    }
    group write_comb_reg {
      y_int0.addr0 = 1'd0;
      y_int0.write_en = 1'd1;
      y_int0.write_data = comb_reg.out;
      write_comb_reg[done] = y_int0.done;
    }
  }

  control {
    seq {
      false;
      par {
        true;
        zero_f0;
      }
      write_comb_reg;
    }
  }
}

The false group sets the value in comb_reg to 0 while true sets it to 1. At the end of the program, we expect the value in comb_reg to be 1 since true will execute on all program paths.

However, tdcc generates the following code for the FSM and the par compilation:

// Group that implements execution of the `par` block
    group par {
      true[go] = !(pd.out | true[done]) ? 1'd1;
      pd.in = true[done] ? 1'd1;
     ...
      par[done] = pd.out & ... ? 1'd1;
    }

Group generated for top-level FSM:

    group tdcc {
      par[go] = false[done] & fsm.out == 2'd0 ? 1'd1;
      par[go] = !par[done] & fsm.out == 2'd1 ? 1'd1;
      ...
    }

The first par[go] statement represents the early transition.

The problem is that both true[done] and false[done] point to comb_reg.done. This creates the following cycle-by-cycle behavior:

  1. cycle 0: false starts executing
  2. cycle f: false is done executing and par starts executing. However, the guard in true[go] = !(pd.out | true[done]) is false because true[done] == false[done]. This also means that pd.in = true[done] ? 1'd1 will execute.
  3. cycle f + 1: true[go] = !(pd.out | true[done]) still doesn't execute because the previous cycle wrote 1 into pd.

This means that true is never executed causing the unexpected output to be generated.

The problem is very similar to a previous bug in tdcc where the done signal from a previous cycle was being used to stop the execution of a group in the current cycle. A possible solution to this problem is exending the guard in the par to be:

true[go] = !(pd.out | (true[done] & fsm.out == 0)) ? 1'd1;

A higher-level statement of this problem is that while registers are allowed to be shared, their done signals cannot be. This class of bus arise from the fact that when we share registers, we invariably end up sharing their done signals as well. The style of fixes to this set of problem is making sure that all the done signals are "indexed" in the right FSM state (i.e. read in the FSM state that they should be read in).

@rachitnigam rachitnigam added Type: Bug Bug in the implementation C: Calyx Extension or change to the Calyx IL Status: Available Can be worked upon labels Sep 10, 2021
@rachitnigam
Copy link
Contributor Author

Argh, just came across a slightly different version of the above example where the control program is:

    seq {
      false;
      par {
        seq { true; zero_f0; }
        zero_f0;  // Ensures that the `par` block doesn't get compiled away.
      }
      write_comb_reg;
    }

My initial thought was that I could just change the compilation of par so that each child's done whole is only read in the correct FSM state of the surrounding context. However, this example does not work with that change. The problem is that the FSM state from the outer context needs to be threaded through all the way to the true group's execution to ensure that its done signal is only read in the right state.

This means that tdcc needs to change a little more dramatically than I expected to allow for threading the current FSM state and ensuring that done signals are read in the right context.

@EclecticGriffin
Copy link
Collaborator

Did this get fixed? If so I'm curious what the correction was

@rachitnigam
Copy link
Contributor Author

Nope, incorrectly closed. The problems is explained here: #651 (comment)

@rachitnigam
Copy link
Contributor Author

The integration test for durbin is disabled because of this issue: cucapra/calyx-evaluation@115b282

@rachitnigam rachitnigam changed the title tdcc: Incorrect FSM generated in presence of par tdcc: Incorrect early transitions in presence of par Nov 13, 2022
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Labels
C: Calyx Extension or change to the Calyx IL Status: Available Can be worked upon Type: Bug Bug in the implementation
Projects