Notifications
You must be signed in to change notification settings - Fork 5
/
dot1xperformancemonitoringhistorydata.go
149 lines (142 loc) · 6.9 KB
/
dot1xperformancemonitoringhistorydata.go
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
/*
* Copyright (c) 2018 - present. Boling Consulting Solutions (bcsw.net)
*
* Licensed under the Apache License, Version 2.0 (the "License");
* you may not use this file except in compliance with the License.
* You may obtain a copy of the License at
* http://www.apache.org/licenses/LICENSE-2.0
* Unless required by applicable law or agreed to in writing, software
* distributed under the License is distributed on an "AS IS" BASIS,
* WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
* See the License for the specific language governing permissions and
* limitations under the License.
*/
/*
* NOTE: This file was generated, manual edits will be overwritten!
*
* Generated by 'goCodeGenerator.py':
* https://github.com/cboling/OMCI-parser/README.md
*/
package generated
import "github.com/deckarep/golang-set"
// Dot1XPerformanceMonitoringHistoryDataClassID is the 16-bit ID for the OMCI
// Managed entity Dot1X performance monitoring history data
const Dot1XPerformanceMonitoringHistoryDataClassID ClassID = ClassID(292)
var dot1xperformancemonitoringhistorydataBME *ManagedEntityDefinition
// Dot1XPerformanceMonitoringHistoryData (class ID #292)
// This ME collects performance statistics on an ONU's IEEE 802.1X CPE authentication operation.
// Instances of this ME are created and deleted by the OLT.
//
// For a complete discussion of generic PM architecture, refer to clause I.4.
//
// Relationships
// An instance of this ME may be associated with each UNI that can perform IEEE-802.1X
// authentication of CPE.
//
// Attributes
// Managed Entity Id
// Managed entity ID: This attribute uniquely identifies each instance of this ME. Through an
// identical ID, this ME is implicitly linked to an instance of a PPTP. (R, setbycreate)
// (mandatory) (2-bytes)
//
// Interval End Time
// Interval end time: This attribute identifies the most recently finished 15-min interval. (R)
// (mandatory) (1-byte)
//
// Threshold Data 1_2 Id
// Threshold data 1/2 ID: This attribute points to an instance of the threshold data 1 and 2 MEs
// that contains PM threshold values. (R,-W, setbycreate) (mandatory) (2-bytes)
//
// Eapol Frames Received
// EAPOL frames received: This attribute counts received valid EAPOL frames of any type. (R)
// (mandatory) (4-bytes)
//
// Eapol Frames Transmitted
// EAPOL frames transmitted: This attribute counts transmitted EAPOL frames of any type. (R)
// (mandatory) (4-bytes)
//
// Eapol Start Frames Received
// EAPOL start frames received: This attribute counts received EAPOL start frames. (R) (mandatory)
// (4-bytes)
//
// Eapol Logoff Frames Received
// EAPOL logoff frames received: This attribute counts received EAPOL logoff frames. (R)
// (mandatory) (4-bytes)
//
// Invalid Eapol Frames Received
// Invalid EAPOL frames received: This attribute counts received EAPOL frames in which the frame
// type was not recognized. (R) (mandatory) (4-bytes)
//
// Eap Resp_Id Frames Received
// EAP resp/id frames received: This attribute counts received EAP response frames containing an
// identifier type field. (R) (mandatory) (4-bytes)
//
// Eap Response Frames Received
// EAP response frames received: This attribute counts received EAP response frames, other than
// resp/id frames. (R) (mandatory) (4-bytes)
//
// Eap Initial Request Frames Transmitted
// EAP initial request frames transmitted: This attribute counts transmitted request frames
// containing an identifier type field. In [IEEE 802.1X], this is also called ReqId. (R)
// (mandatory) (4-bytes)
//
// Eap Request Frames Transmitted
// EAP request frames transmitted: This attribute counts transmitted request frames, other than
// request/id frames. (R) (mandatory) (4-bytes)
//
// Eap Length Error Frames Received
// EAP length error frames received: This attribute counts received EAPOL frames whose packet body
// length field was invalid. (R) (mandatory) (4-bytes)
//
// Eap Success Frames Generated Autonomously
// EAP success frames generated autonomously: This attribute counts EAPOL success frames generated
// according to the local fallback policy because no radius server was available. (R) (mandatory)
// (4-bytes)
//
// Eap Failure Frames Generated Autonomously
// EAP failure frames generated autonomously: This attribute counts EAPOL failure frames generated
// according to the local fallback policy because no radius server was available. (R) (mandatory)
// (4-bytes)
//
type Dot1XPerformanceMonitoringHistoryData struct {
ManagedEntityDefinition
Attributes AttributeValueMap
}
func init() {
dot1xperformancemonitoringhistorydataBME = &ManagedEntityDefinition{
Name: "Dot1XPerformanceMonitoringHistoryData",
ClassID: 292,
MessageTypes: mapset.NewSetWith(
Create,
Delete,
Get,
Set,
),
AllowedAttributeMask: 0xfffc,
AttributeDefinitions: AttributeDefinitionMap{
0: Uint16Field("ManagedEntityId", 0, mapset.NewSetWith(Read, SetByCreate), false, false, false, false, 0),
1: ByteField("IntervalEndTime", 0, mapset.NewSetWith(Read), false, false, false, false, 1),
2: Uint16Field("ThresholdData12Id", 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, false, 2),
3: Uint32Field("EapolFramesReceived", 0, mapset.NewSetWith(Read), false, false, false, false, 3),
4: Uint32Field("EapolFramesTransmitted", 0, mapset.NewSetWith(Read), false, false, false, false, 4),
5: Uint32Field("EapolStartFramesReceived", 0, mapset.NewSetWith(Read), false, false, false, false, 5),
6: Uint32Field("EapolLogoffFramesReceived", 0, mapset.NewSetWith(Read), false, false, false, false, 6),
7: Uint32Field("InvalidEapolFramesReceived", 0, mapset.NewSetWith(Read), false, false, false, false, 7),
8: Uint32Field("EapRespIdFramesReceived", 0, mapset.NewSetWith(Read), false, false, false, false, 8),
9: Uint32Field("EapResponseFramesReceived", 0, mapset.NewSetWith(Read), false, false, false, false, 9),
10: Uint32Field("EapInitialRequestFramesTransmitted", 0, mapset.NewSetWith(Read), false, false, false, false, 10),
11: Uint32Field("EapRequestFramesTransmitted", 0, mapset.NewSetWith(Read), false, false, false, false, 11),
12: Uint32Field("EapLengthErrorFramesReceived", 0, mapset.NewSetWith(Read), false, false, false, false, 12),
13: Uint32Field("EapSuccessFramesGeneratedAutonomously", 0, mapset.NewSetWith(Read), false, false, false, false, 13),
14: Uint32Field("EapFailureFramesGeneratedAutonomously", 0, mapset.NewSetWith(Read), false, false, false, false, 14),
},
Access: UnknownAccess,
Support: UnknownSupport,
}
}
// NewDot1XPerformanceMonitoringHistoryData (class ID 292) creates the basic
// Managed Entity definition that is used to validate an ME of this type that
// is received from or transmitted to the OMCC.
func NewDot1XPerformanceMonitoringHistoryData(params ...ParamData) (*ManagedEntity, OmciErrors) {
return NewManagedEntity(*dot1xperformancemonitoringhistorydataBME, params...)
}