Notifications
You must be signed in to change notification settings - Fork 5
/
xdsllineconfigurationprofilepart2.go
180 lines (173 loc) · 10.9 KB
/
xdsllineconfigurationprofilepart2.go
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
/*
* Copyright (c) 2018 - present. Boling Consulting Solutions (bcsw.net)
*
* Licensed under the Apache License, Version 2.0 (the "License");
* you may not use this file except in compliance with the License.
* You may obtain a copy of the License at
* http://www.apache.org/licenses/LICENSE-2.0
* Unless required by applicable law or agreed to in writing, software
* distributed under the License is distributed on an "AS IS" BASIS,
* WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
* See the License for the specific language governing permissions and
* limitations under the License.
*/
/*
* NOTE: This file was generated, manual edits will be overwritten!
*
* Generated by 'goCodeGenerator.py':
* https://github.com/cboling/OMCI-parser/README.md
*/
package generated
import "github.com/deckarep/golang-set"
// XdslLineConfigurationProfilePart2ClassID is the 16-bit ID for the OMCI
// Managed entity xDSL line configuration profile part 2
const XdslLineConfigurationProfilePart2ClassID ClassID = ClassID(105)
var xdsllineconfigurationprofilepart2BME *ManagedEntityDefinition
// XdslLineConfigurationProfilePart2 (class ID #105)
// The overall xDSL line configuration profile is modelled in several parts, all of which are
// associated together through a common ME ID (the client PPTP xDSL UNI part 1 has a single
// pointer, which refers to the entire set of line configuration profile parts).
//
// Relationships
// An instance of this ME may be associated with zero or more instances of an xDSL UNI.
//
// Attributes
// Managed Entity Id
// Managed entity ID: This attribute uniquely identifies each instance of this ME. All xDSL and
// VDSL2 line configuration profiles and extensions that pertain to a given PPTP xDSL UNI must
// share a common ME ID. (R, setbycreate) (mandatory) (2-bytes)
//
// Downstream Minimum Time Interval For Upshift Rate Adaptation
// Downstream minimum time interval for upshift rate adaptation: This parameter defines the
// interval during which the downstream noise margin must remain above the downstream upshift noise
// margin before the xTU-R attempts to increase the downstream net data rate. Its value ranges from
// 0 to 16383-s. (R,-W, setbycreate) (optional) (2-bytes)
//
// Upstream Minimum Time Interval For Upshift Rate Adaptation
// Upstream minimum time interval for upshift rate adaptation: This parameter defines the interval
// during which the upstream noise margin must remain above the upstream upshift noise margin
// before the xTU-C attempts to increase the upstream net data rate. Its value ranges from 0 to
// 16383-s. (R,-W, setbycreate) (optional) (2-bytes)
//
// Downstream Downshift Noise Margin
// Downstream downshift noise margin: If the downstream noise margin is below the downstream
// downshift noise margin and remains there for more than the downstream minimum time interval for
// downshift rate adaptation, the xTU-R attempts to decrease the downstream net data rate. This
// attribute's value ranges from 0 (0.0 dB) to 310 (31.0 dB). (R,-W, setbycreate) (optional)
// (2-bytes)
//
// Upstream Downshift Noise Margin
// Upstream downshift noise margin: If the upstream noise margin is below the upstream downshift
// noise margin and remains there for more than the upstream minimum time interval for downshift
// rate adaptation, the xTUC attempts to decrease the upstream net data rate. This attribute's
// value ranges from 0 (0.0 dB) to 310 (31.0 dB). (R,-W, setbycreate) (optional) (2-bytes)
//
// Downstream Minimum Time Interval For Downshift Rate Adaptation
// Downstream minimum time interval for downshift rate adaptation: This parameter defines the
// interval during which the downstream noise margin must remain below the downstream downshift
// noise margin before the xTU-R attempts to decrease the downstream net data rate. Its value
// ranges from 0 to 16383-s. (R,-W, setbycreate) (optional) (2-bytes)
//
// Upstream Minimum Time Interval For Downshift Rate Adaptation
// Upstream minimum time interval for downshift rate adaptation: This parameter defines the
// interval during which the upstream noise margin must remain below the upstream downshift noise
// margin before the xTU-C attempts to decrease the upstream net data rate. Its value ranges from 0
// to 16383-s. (R,-W, setbycreate) (optional) (2-bytes)
//
// Xtu Impedance State Forced
// (R,-W, setbycreate) (optional) (1-byte)
//
// L0_Time
// L0-time: This parameter specifies the minimum time between an exit from the L2 state and the
// next entry into the L2 state. It is only valid for [ITUT-G.992.3], [ITUT-G.992.4] and
// [ITUT-G.992.5]. It ranges from 0 to 255-s. (R,-W, setbycreate) (mandatory) (1 byte)
//
// L2_Time
// L2-time: This parameter specifies the minimum time between an entry into the L2 state and the
// first power trim in the L2 state, or between two consecutive power trims in the L2 state. It is
// only valid for [ITUT-G.992.3], [ITUT-G.992.4] and [ITUT-G.992.5]. It ranges from 0 to 255-s. (R,
// W, setbycreate) (mandatory) (1 byte)
//
// Downstream Maximum Nominal Power Spectral Density
// Downstream maximum nominal power spectral density: This attribute specifies the maximum nominal
// transmit PSD in the downstream direction during initialization and showtime. A single
// MAXNOMPSDds attribute is defined per mode enabled in the xTSE line configuration attribute. It
// is only valid for [ITUT-G.992.3], [ITUT-G.992.4] and [ITUT-G.992.5]. Its value ranges from 0
// (60.0-dBm/Hz) to 300 (-30-dBm/Hz). (R, W, setbycreate) (mandatory) (2 bytes)
//
// Upstream Maximum Nominal Power Spectral Density
// Upstream maximum nominal power spectral density: This attribute specifies the maximum nominal
// transmit PSD in the upstream direction during initialization and showtime. A single MAXNOMPSDus
// attribute is defined per mode enabled in the xTSE line configuration attribute. It is only valid
// for [ITUT-G.992.3], [ITUT-G.992.4] and [ITUT-G.993.2]. Its value ranges from 0 (-60.0-dBm/Hz) to
// 300 (-30-dBm/Hz). (R, W, setbycreate) (mandatory) (2 bytes)
//
// Downstream Maximum Nominal Aggregate Transmit Power
// Downstream maximum nominal aggregate transmit power: This attribute specifies the maximum
// nominal aggregate transmit power in the downstream direction during initialization and showtime.
// It is only valid for [ITUT-G.992.3], [ITUT-G.992.4], [ITUT-G.992.5] and [ITUT-G.993.2]. Its
// value ranges from 0 (0.0-dBm) to 255 (25.5-dBm). (R, W, setbycreate) (mandatory) (1-byte)
//
// Upstream Maximum Nominal Aggregate Transmit Power
// Upstream maximum nominal aggregate transmit power: This parameter specifies the maximum nominal
// aggregate transmit power in the upstream direction during initialization and showtime. It is
// only valid for [ITUT-G.992.3], [ITUT-G.992.4] and [ITUT-G.992.5]. Its value ranges from 0
// (0.0-dBm) to 255 (25.5-dBm). (R, W, setbycreate) (mandatory) (1 byte)
//
// Upstream Maximum Aggregate_Receive Power
// Upstream maximum aggregate-receive power: This parameter specifies the maximum upstream
// aggregate receive power over a set of subcarriers, as defined in the relevant Recommendation.
// The xTU-C requests an upstream power cutback such that the upstream aggregate receive power over
// that set of subcarriers is at or below the configured maximum value. It is only valid for
// [ITUT-G.992.3], [ITUT-G.992.4] and [ITUT-G.992.5]. This attribute ranges from 0 (25.5-dBm) to
// 510 (+25.5-dBm). The special value 0xFFFF indicates that no upstream maximum aggregate receive
// power limit is to be applied. (R, W setbycreate) (mandatory) (2 bytes)
//
// Vdsl2 Transmission System Enabling
// VDSL2 transmission system enabling: This configuration attribute extends the transmission system
// coding types to be allowed by the xTU-C. It is a bit map, defined as octet 8 (bits 57..64) in
// Table-9.7.12-1. (R, W, setbycreate) (optional) (1 byte)
//
type XdslLineConfigurationProfilePart2 struct {
ManagedEntityDefinition
Attributes AttributeValueMap
}
func init() {
xdsllineconfigurationprofilepart2BME = &ManagedEntityDefinition{
Name: "XdslLineConfigurationProfilePart2",
ClassID: 105,
MessageTypes: mapset.NewSetWith(
Create,
Delete,
Get,
Set,
),
AllowedAttributeMask: 0xfffe,
AttributeDefinitions: AttributeDefinitionMap{
0: Uint16Field("ManagedEntityId", 0, mapset.NewSetWith(Read, SetByCreate), false, false, false, false, 0),
1: Uint16Field("DownstreamMinimumTimeIntervalForUpshiftRateAdaptation", 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, true, false, 1),
2: Uint16Field("UpstreamMinimumTimeIntervalForUpshiftRateAdaptation", 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, true, false, 2),
3: Uint16Field("DownstreamDownshiftNoiseMargin", 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, true, false, 3),
4: Uint16Field("UpstreamDownshiftNoiseMargin", 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, true, false, 4),
5: Uint16Field("DownstreamMinimumTimeIntervalForDownshiftRateAdaptation", 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, true, false, 5),
6: Uint16Field("UpstreamMinimumTimeIntervalForDownshiftRateAdaptation", 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, true, false, 6),
7: ByteField("XtuImpedanceStateForced", 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, true, false, 7),
8: ByteField("L0Time", 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, false, 8),
9: ByteField("L2Time", 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, false, 9),
10: Uint16Field("DownstreamMaximumNominalPowerSpectralDensity", 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, false, 10),
11: Uint16Field("UpstreamMaximumNominalPowerSpectralDensity", 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, false, 11),
12: ByteField("DownstreamMaximumNominalAggregateTransmitPower", 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, false, 12),
13: ByteField("UpstreamMaximumNominalAggregateTransmitPower", 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, false, false, 13),
14: Uint16Field("UpstreamMaximumAggregateReceivePower", 0, mapset.NewSetWith(Read), false, false, false, false, 14),
15: ByteField("Vdsl2TransmissionSystemEnabling", 0, mapset.NewSetWith(Read, SetByCreate, Write), false, false, true, false, 15),
},
Access: UnknownAccess,
Support: UnknownSupport,
}
}
// NewXdslLineConfigurationProfilePart2 (class ID 105) creates the basic
// Managed Entity definition that is used to validate an ME of this type that
// is received from or transmitted to the OMCC.
func NewXdslLineConfigurationProfilePart2(params ...ParamData) (*ManagedEntity, OmciErrors) {
return NewManagedEntity(*xdsllineconfigurationprofilepart2BME, params...)
}